Standard Specification for Window Fall Prevention Devices With Emergency Escape (Egress) Release Mechanisms

ABSTRACT
This specification establishes the installation, safety, performance, and labeling requirements for devices intended to address the risk of injury and death associated with accidental falls from windows by children five years old and younger. It applies to window fall prevention devices that are to be used on any window, including those that are designated for emergency escape (egress) and rescue (ingress). It is, however, not intended to meet the unique requirements of the Americans with Disabilities Act (ADA).
SCOPE
1.1 This specification establishes requirements for devices intended to address the risk of injury and death associated with accidental falls through open windows by children five years old and younger.
1.2 This specification is not intended to meet the unique requirements of Americans With Disabilities Act (ADA).
1.3 This specification applies to window fall prevention devices, including window opening control devices, window fall prevention screens, and fall prevention window guards, that are to be used on any windows, including those that are designated for emergency escape (egress) and rescue (ingress).
Note 1—A separate safety specification, Safety Specification F2006, covers window fall prevention devices for non-emergency escape (egress) and rescue (ingress) windows in installations more than 75 ft (23 m) above ground level in multiple family dwelling buildings since windows at these heights are beyond the reach of rescue ladders currently in use.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
14-Mar-2010
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F2090-10 - Standard Specification for Window Fall Prevention Devices With Emergency Escape (Egress) Release Mechanisms
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F2090-10 - Standard Specification for Window Fall Prevention Devices With Emergency Escape (Egress) Release Mechanisms
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F2090 −10
StandardSpecification for
Window Fall Prevention Devices With Emergency Escape
1
(Egress) Release Mechanisms
This standard is issued under the fixed designation F2090; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
This consumer safety specification addresses window fall prevention devices that protect against
potential falls by children aged five years and under through open windows. Window fall prevention
devices currently available include window opening control devices, window fall prevention screens,
and some types of window guards. These devices use different strategies to prevent children from
falling through open windows. Window opening control devices restrict the size of the open area of
the window so that it is too small for a young child to fall through. They do this by allowing the
window opening to be set at a predetermined position. Window fall prevention screens and fall
prevention window guards provide a barrier to prevent a child from falling through an open window.
2
A special study by the U.S. Consumer Product Safety Commission (CPSC) indicates that young
children are at risk of death and serious injury from falls through open windows. Children aged five
3
and younger account for a higher percentage of window fall fatalities and injuries.
Windowfallpreventiondevicesusuallydifferinpurposeandapplicationfromsecurity/burglarbars.
The general purpose of a window fall prevention device is to prevent a child age five or younger from
falling through an open window. The general purpose of a security bar is to prevent unlawful entry
through a window. Generally window fall prevention devices and security bars are two separate
devices. However, a security bar could be used as a fall prevention device if it meets the requirements
of this specification.
The CPSC has advised caregivers to open windows less than 4 in. when children are present as one
means to prevent child falls through open windows.Window opening control devices provide a means
that the window, when opened in an initial operation, will satisfy the CPSC recommendation to open
4
less than 4 in. The 4-in. dimension is drawn from related building codes and standards for openings
5
in guardrail assemblies, and is universally accepted as the appropriate dimension to prevent a child
frompassingthroughbalconyorguardrailingsystems.Anadditionaloperationisrequiredtoopenthe
window further. The additional operation must be performed without the use of keys, tools, or special
knowledge. Security from forced entry is not within the scope of this standard and is not the intended
function of any of the devices referred to herein.
1. Scope
1.1 This specification establishes requirements for devices
1
This specification is under the jurisdiction of ASTM Committee F15 on
intended to address the risk of injury and death associated with
Consumer Products and is the direct responsibility of Subcommittee F15.38 on
Window Fall Prevention.
accidental falls through open windows by children five years
Current edition approved March 15, 2010. Published April 2010. Originally
old and younger.
approved in 2001. Last previous edition approved in 2008 as F2090 – 08. DOI:
10.1520/F2090-10.
1.2 This specification is not intended to meet the unique
2
U.S. Consumer Product Safety Commission, Special Window Falls Study,
requirements of Americans With Disabilities Act (ADA).
conducted in 1991.
3
U.S. Consumer Product Safety Commission, Special Window Falls Study,
1.3 This specification applies to window fall prevention
conducted in 1991 and “Window Safety: Data and Patterns Related to Entrapments
devices, including window opening control devices, window
and Accidental Falls from Windows,” prepared by Andersen Corporation.
Supporting data have been filed atASTM International Headquarters and may be
obtained by requesting Research Report RR:F15-1002.
4 5
Consumer Product Safety Commission, “PreventingWindow Falls,” Document See NFPA 101, 2006 Edition, Section 7.2.2.4.5.3. Also see Section R312.2,
#5124. guard opening limitations in the 2006 International Residential Code (IRC).
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2090−10
10
fall prevention screens, and fall prevention window guards, 2.4 AAMA Standards:
that are to be used on any windows, including those that are AAMA/WDMA/CSA 101/IS.2/A440-08 North American
Fenestration Standard/Specification for Windows, Doors,
designated for emergency escape (egress) and
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:F2090–08 Designation: F2090 – 10
Standard Specification for
Window Fall Prevention Devices With Emergency Escape
1
(Egress) Release Mechanisms
This standard is issued under the fixed designation F2090; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
This consumer safety specification addresses window fall prevention devices that protect against
potential falls by children aged five years and under through open windows. Window fall prevention
devices currently available include window opening control devices, window fall prevention screens,
and some types of window guards. These devices use different strategies to prevent children from
falling through open windows. Window opening control devices restrict the size of the open area of
the window so that it is too small for a young child to fall through. They do this by allowing the
window opening to be set at a predetermined position. Window fall prevention screens and fall
prevention window guards provide a barrier to prevent a child from falling through an open window.
2
A special study by the U.S. Consumer Product Safety Commission (CPSC) indicates that young
children are at risk of death and serious injury from falls through open windows. Children aged five
3
and younger account for a higher percentage of window fall fatalities and injuries.
Windowfallpreventiondevicesusuallydifferinpurposeandapplicationfromsecurity/burglarbars.
The general purpose of a window fall prevention device is to prevent a child age five or younger from
falling through an open window. The general purpose of a security bar is to prevent unlawful entry
through a window. Generally window fall prevention devices and security bars are two separate
devices. However, a security bar could be used as a fall prevention device if it meets the requirements
of this specification.
The CPSC has advised caregivers to open windows less than 4 in. when children are present as one
means to prevent child falls through open windows.Window opening control devices provide a means
that the window, when opened in an initial operation, will satisfy the CPSC recommendation to open
4
less than 4 in. The 4-in. dimension is drawn from related building codes and standards for openings
5
in guardrail assemblies, and is universally accepted as the appropriate dimension to prevent a child
frompassingthroughbalconyorguardrailingsystems.Anadditionaloperationisrequiredtoopenthe
window further. The additional operation must be performed without the use of keys, tools, or special
knowledge. Security from forced entry is not within the scope of this standard and is not the intended
function of any of the devices referred to herein.
1. Scope
1.1 This specification establishes requirements for devices intended to address the risk of injury and death associated with
accidental falls through open windows by children five years old and younger.
1.2 This specification is not intended to meet the unique requirements of Americans With Disabilities Act (ADA).
1.3 This specification applies to window fall prevention devices, including window opening control devices, window fall
1
This specification is under the jurisdiction of ASTM Committee F15 on Consumer Products and is the direct responsibility of Subcommittee F15.38 on Window Fall
Prevention.
Current edition approved Nov. 1, 2008. Published January 2009. Originally approved in 2001. Last previous edition approved in 2007 as F2090–01a (2007). DOI:
10.1520/F2090-08.
Current edition approved March 15, 2010. Published April 2010. Originally approved in 2001. Last previous edition approved in 2008 as F2090 – 08. DOI:
10.1520/F2090-10.
2
U.S. Consumer Product Safety Commission, Special Window Falls Study, conducted in 1991.
3
U.S. Consumer Product Safety Commission, Special Window Falls Study, conducted in 1991 and “Window Safety: Data and Patterns Related to Entrapments and
Accidental Falls from Windows,” prepared by Andersen Corporation.
Supporting data have been filed at ASTM International Headquarters and may be obtained by requesting Research Report RR:F15-1002.
4
Consumer Product Safety Commission, “Preventing Window Falls,” Document #5124.
5
See NFPA 101, 2006 Edition, Section 7.2.2.4.5.3. Also see Section R312.2, guard opening limitations in the 2006 International Residential Cod
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.