ASTM F1090-06
(Classification)Standard Classification for Bank and Mercantile Vault Construction
Standard Classification for Bank and Mercantile Vault Construction
SIGNIFICANCE AND USE
This classification is meant to be a guide for the selection of a vault.
This classification is intended to assist users in availing themselves of various prefabricated and generically constructed products, while maintaining continuity in the selected intrusion-resistance level.
This classification is not meant to recommend or prefer the use of any single product or any type level, or its application.
SCOPE
1.1 This classification is for the use and guidance of those who purchase, design, construct, install, approve, or modify storage vault enclosures, intended for the protection of assets against loss due to forced entry.
1.2 This classification is a systematic arrangement of constructed products, based on similar intrusion resistance characteristics, as derived from available test data.
1.3 This classification does not address fire resistivity.
1.4 This classification does not address the methods of interfacing vault components.
1.5 Nothing in this classification is intended to prevent the use of systems, methods, or devices that provide a level of intrusion resistance equivalent to that prescribed herein.
1.5.1 Any system, method, or device different from that detailed herein may be examined, in accordance with the intent of this standard, and if found equivalent, may be included.
1.6 Nothing in this classification shall be construed to prohibit better or safer conditions than the requirements specified herein.
1.7 Each standard designation cited shall be meant to be the edition in effect on the date this classification was published.
1.8 A rationale is given in . For more information on the construction of bank and mercantile vaults, refer to the following documents: ASTM Specifications A 184/A 184M, A 615/A 615M, A 635/A 635M, C 33, C 94/C 94M, C 150, C 494/C 494M, C 618, C 685/C 685M; American Concrete Institute Building Requirements ACI 318, and American Welding Society Structural Welding Code D 1.4.
1.9 The values stated in inch-pound units are to be regarded as the standard. The values in parentheses are given for information only.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F1090 −06
StandardClassification for
1
Bank and Mercantile Vault Construction
This standard is issued under the fixed designation F1090; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 This classification is for the use and guidance of those
A184/A184M Specification for Welded Deformed Steel Bar
who purchase, design, construct, install, approve, or modify
Mats for Concrete Reinforcement
storage vault enclosures, intended for the protection of assets
A615/A615M SpecificationforDeformedandPlainCarbon-
against loss due to forced entry.
Steel Bars for Concrete Reinforcement
1.2 This classification is a systematic arrangement of con-
A635/A635M Specification for Steel, Sheet and Strip,
structed products, based on similar intrusion resistance
Heavy-Thickness Coils, Hot-Rolled, Alloy, Carbon,
characteristics, as derived from available test data.
Structural, High-Strength Low-Alloy, and High-Strength
Low-Alloy with Improved Formability, General Require-
1.3 This classification does not address fire resistivity.
ments for
1.4 This classification does not address the methods of
A820/A820M Specification for Steel Fibers for Fiber-
interfacing vault components. Reinforced Concrete
C33 Specification for Concrete Aggregates
1.5 Nothing in this classification is intended to prevent the
C39/C39M Test Method for Compressive Strength of Cylin-
use of systems, methods, or devices that provide a level of
drical Concrete Specimens
intrusion resistance equivalent to that prescribed herein.
C94/C94M Specification for Ready-Mixed Concrete
1.5.1 Any system, method, or device different from that
C150 Specification for Portland Cement
detailed herein may be examined, in accordance with the intent
C494/C494M Specification for Chemical Admixtures for
of this standard, and if found equivalent, may be included.
Concrete
C618 Specification for Coal Fly Ash and Raw or Calcined
1.6 Nothing in this classification shall be construed to
Natural Pozzolan for Use in Concrete
prohibit better or safer conditions than the requirements
C685/C685M Specification for Concrete Made by Volumet-
specified herein.
ric Batching and Continuous Mixing
1.7 Each standard designation cited shall be meant to be the
C1116 Specification for Fiber-Reinforced Concrete and
edition in effect on the date this classification was published.
Shotcrete
3
2.2 Underwriters Laboratories Standards:
1.8 A rationale is given in Appendix X1.
UL 608 Burglary-Resistant Vault Doors and Modular Panels
NOTE 1—For more information on the construction of bank and UL 680 Emergency Vault Ventilators and Vault Ventilating
mercantile vaults, refer to the following documents:ASTM Specifications
Ports
4
A184/A184M, A615/A615M, A635/A635M, C33, C94/C94M, C150,
2.3 American Concrete Institute Document:
C494/C494M, C618, C685/C685M;American Concrete Institute Building
ACI 318 Building Code Requirements for Reinforced Con-
Requirements ACI 318, and American Welding Society Structural Weld-
crete
ing Code D 1.4.
5
2.4 American Welding Society Document:
1.9 The values stated in inch-pound units are to be regarded
D 1.4 Structural Welding Code Reinforcing Steel
as the standard. The values in parentheses are given for
information only.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
1 3
This classification is under the jurisdiction of ASTM Committee F12 on Available from Underwriters Laboratories (UL), Corporate Progress, 333
Security Systems and Equipmentand is the direct responsibility of Subcommittee Pfingsten Rd., Northbrook, IL 60062.
4
F12.10 on Systems Products and Services. Available fromAmerican Concrete Institute (ACI), P.O. Box 9094, Farmington
Current edition approved Feb. 1, 2006. Published February 2006. Originally Hills, MI 48333.
´1
5
approved in 1987. Last previous edition approved in 1997 as F1090 – 87 (1997) . Available from American Welding Society (AWS), 550 NW LeJeune Rd.,
DOI: 10.1520/F1090-06. Miami, FL 33126.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
F1090−06
3. Description of Terms Specific to this Standard 5.3.1.2 Modular panels bearing the label “Class M” from an
independent, third party, accredited testing laboratory, and
3.1 alternate construction—a substitute method of fabrica-
5.3.1.3 Vault
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.