ASTM C506M-14
(Specification)Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe (Metric)
Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe (Metric)
ABSTRACT
This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. Pipe manufactured according to this specification shall be of three classes identified as Class A-II, A-III, and A-IV. The reinforced concrete shall consist of cementitious materials, mineral aggregates, and water, in which steel has been embedded in such a manner that the steel and concrete act together. The pipe shall be designed to meet both the 0.01 in. crack and ultimate strength requirements determined by conducting plant load bearing tests, material tests, and inspection of manufactured pipe for visual defects and imperfections. The reinforcement, joint, and manufacture are detailed.
SCOPE
1.1 This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts.
1.2 This specification is the SI companion to Specification C506. Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C506M −14
StandardSpecification for
Reinforced Concrete Arch Culvert, Storm Drain, and Sewer
1
Pipe (Metric)
This standard is issued under the fixed designation C506M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope pounds for Curing Concrete
C494/C494M Specification for Chemical Admixtures for
1.1 This specification covers reinforced arch-shaped con-
Concrete
crete pipe to be used for the conveyance of sewage, industrial
C497M Test Methods for Concrete Pipe, Manhole Sections,
wastes, storm water, and for the construction of culverts.
or Tile (Metric)
1.2 This specification is the SI companion to Specification
C595 Specification for Blended Hydraulic Cements
C506.
C618 Specification for Coal Fly Ash and Raw or Calcined
Natural Pozzolan for Use in Concrete
NOTE 1—This specification is a manufacturing and purchase specifica-
tion only, and does not include requirements for bedding, backfill, or the
C822 Terminology Relating to Concrete Pipe and Related
relationship between field load condition and the strength classification of
Products
pipe. However, experience has shown that the successful performance of
C989 Specification for Slag Cement for Use in Concrete and
this product depends upon the proper selection of the class of pipe, type
Mortars
of bedding and backfill, and care that the installation conforms to the
C1017/C1017M Specification for Chemical Admixtures for
construction specifications. The owner of the reinforced concrete pipe
specified herein is cautioned that he must correlate the field requirements
Use in Producing Flowing Concrete
with the class of pipe specified and provide inspection at the construction
C1116 Specification for Fiber-Reinforced Concrete and
site.
Shotcrete
C1602/C1602M Specification for Mixing Water Used in the
2. Referenced Documents
Production of Hydraulic Cement Concrete
2
2.1 ASTM Standards:
A36/A36M Specification for Carbon Structural Steel
3. Terminology
A615/A615M SpecificationforDeformedandPlainCarbon-
3.1 Definitions—For definitions of terms relating to con-
Steel Bars for Concrete Reinforcement
crete pipe, see Terminology C822.
A706/A706M Specification for Deformed and Plain Low-
Alloy Steel Bars for Concrete Reinforcement
4. Classification
A1064/A1064M Specification for Carbon-Steel Wire and
4.1 Pipe manufactured according to this specification shall
Welded Wire Reinforcement, Plain and Deformed, for
beofthreeclassesidentifiedasClassA-II,A-III,andA-IV.The
Concrete
strength requirements are prescribed in Table 1.
C33 Specification for Concrete Aggregates
C150 Specification for Portland Cement
5. Basis of Acceptance
C260 Specification for Air-Entraining Admixtures for Con-
5.1 Unlessotherwisedesignatedbytheowneratthetimeof,
crete
or before placing an order, there are two separate and alterna-
C309 Specification for Liquid Membrane-Forming Com-
tive bases of acceptance. Independent of the method of
acceptance, the pipe shall be designed to meet both the 0.01-in.
1
This specification is under the jurisdiction of ASTM Committee C13 on
crack and ultimate strength requirements.
Concrete Pipe and is the direct responsibility of Subcommittee C13.02 on
5.1.1 Acceptance on Basis of Plant Load Bearing Tests,
Reinforced Sewer and Culvert Pipe.
Material Tests, and Inspection of Manufactured Pipe for Visual
Current edition approved Feb. 1, 2014. Published March 2014. Originally
Defects and Imperfections—Acceptability of the pipe in all
approved in 1980. Last previous edition approved in 2013 as C506M – 13a. DOI:
10.1520/C0506M-14.
diameters and classes produced in accordance with 7.1 or 7.2
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
shall be determined by the results of the three-edge-bearing
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
tests as defined in 11.3.1; by such material tests as are required
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. in accordance with 6.2, 6.3, 6.5, and 6.6, by an absorption test
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C506M−14
A
TABLE 1 Strength Requirements for Reinforced Concrete Pipe
C
Double Line Reinforcement
B
f'c MPa
Continuous Basic Reinforcement = A
Approx- D
Additional Reinforcement = A Single Line
D s
s
imate Mini- Mini-
Reinforcement
Equivalent T, mum mum
“U ” “V ”
Class Inner Cage Outer Cage
Round mm Rise, Span,
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C506M − 13a C506M − 14
Standard Specification for
Reinforced Concrete Arch Culvert, Storm Drain, and Sewer
1
Pipe (Metric)
This standard is issued under the fixed designation C506M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope
1.1 This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes,
storm water, and for the construction of culverts.
1.2 This specification is the SI companion to Specification C506.
NOTE 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the
relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this
product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction
specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe
specified and provide inspection at the construction site.
2. Referenced Documents
2
2.1 ASTM Standards:
A36/A36M Specification for Carbon Structural Steel
A615/A615M Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement
A706/A706M Specification for Low-Alloy Steel Deformed and Plain Bars for Concrete Reinforcement
A1064/A1064M Specification for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete
C33 Specification for Concrete Aggregates
C150 Specification for Portland Cement
C260 Specification for Air-Entraining Admixtures for Concrete
C309 Specification for Liquid Membrane-Forming Compounds for Curing Concrete
C494/C494M Specification for Chemical Admixtures for Concrete
C497M Test Methods for Concrete Pipe, Manhole Sections, or Tile (Metric)
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C822 Terminology Relating to Concrete Pipe and Related Products
C989 Specification for Slag Cement for Use in Concrete and Mortars
C1017/C1017M Specification for Chemical Admixtures for Use in Producing Flowing Concrete
C1116 Specification for Fiber-Reinforced Concrete and Shotcrete
C1602/C1602M Specification for Mixing Water Used in the Production of Hydraulic Cement Concrete
3. Terminology
3.1 Definitions—For definitions of terms relating to concrete pipe, see Terminology C822.
4. Classification
4.1 Pipe manufactured according to this specification shall be of three classes identified as Class A-II, A-III, and A-IV. The
strength requirements are prescribed in Table 1.
1
This specification is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.02 on Reinforced Sewer
and Culvert Pipe.
Current edition approved Feb. 15, 2013Feb. 1, 2014. Published March 2013March 2014. Originally approved in 1980. Last previous edition approved in 2013 as
C506M – 13.C506M – 13a. DOI: 10.1520/C0506M-13A.10.1520/C0506M-14.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C506M − 14
A
TABLE 1 Strength Requirements for Reinforced Concrete Pipe
C
Double Line Reinforcement
B
f'c MPa
Continuous Basic Reinforcement = A
D
Approx-
Additional Reinforcement = A Single Line
D s
s
imate Mini- Mini-
Reinforcement
Equivalent T, mum mum
“U ” “V ”
Class Inner Cage Outer Cage
Round mm Rise, Span,
(Inner Cage) (Outer Cage)
Size, mm mm
Dimen- Dimen-
mm
A-II A-III A-IV A-II A-III A-IV A-II A-III A-IV sion, A-II A-III A-IV sion, A-II A-III A-IV A-II A-III A-IV
mm mm
375 57 280 460 27.6 27.6 27.6 . . . . . . . . . . . . . . 1.7 2.5 3.6
450 63 345 560 27.6 27.6 27.6 . . . . . . . . . . . . . . 2.3 3.0 5.5
525 69 395 6
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.