ASTM C1818-18
(Specification)Standard Specification for Synthetic Fiber Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe
Standard Specification for Synthetic Fiber Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe
SCOPE
1.1 This specification covers synthetic fiber reinforced concrete pipe (Syn-FRCP) of internal diameters 12-48 in., intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts.
Note 1: Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.
Note 2: This product is a rigid pipe and it does not depend upon deflection (pipe stiffness) for additional support from the soil.
Note 3: This standard requires long-term testing of Syn-FRCP in accordance with Section 9 that goes above and beyond what is typically required for steel reinforced concrete pipe, in order to evaluate the long-term material strength of the fiber-concrete matrix.
1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1818 −18
Standard Specification for
Synthetic Fiber Reinforced Concrete Culvert, Storm Drain,
1
and Sewer Pipe
This standard is issued under the fixed designation C1818; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* C150/C150MSpecification for Portland Cement
C260/C260MSpecification for Air-Entraining Admixtures
1.1 This specification covers synthetic fiber reinforced con-
for Concrete
crete pipe (Syn-FRCP) of internal diameters 12-48 in., in-
C309Specification for Liquid Membrane-Forming Com-
tended to be used for the conveyance of sewage, industrial
pounds for Curing Concrete
wastes, and storm water and for the construction of culverts.
C494/C494MSpecification for Chemical Admixtures for
NOTE 1—Experience has shown that the successful performance of this
Concrete
productdependsupontheproperselectionofthepipestrength,thetypeof
C497Test Methods for Concrete Pipe, Manhole Sections, or
bedding and backfill, the care that the installation conforms to the
Tile
construction specifications, and provision for adequate inspection at the
C595/C595MSpecification for Blended Hydraulic Cements
construction site. This specification does not include requirements for
bedding, backfill, the relationship between field load conditions and the
C618Specification for Coal Fly Ash and Raw or Calcined
strength designation of pipe, or durability under unusual environmental
Natural Pozzolan for Use in Concrete
conditions. These requirements should be included in the project specifi-
C822Terminology Relating to Concrete Pipe and Related
cation.
Products
NOTE 2—This product is a rigid pipe and it does not depend upon
deflection (pipe stiffness) for additional support from the soil. C989/C989MSpecification for Slag Cement for Use in
NOTE 3—This standard requires long-term testing of Syn-FRCP in
Concrete and Mortars
accordance with Section 9 that goes above and beyond what is typically
C1017/C1017MSpecification for Chemical Admixtures for
required for steel reinforced concrete pipe, in order to evaluate the
Use in Producing Flowing Concrete
long-term material strength of the fiber-concrete matrix.
C1116/C1116MSpecification for Fiber-Reinforced Concrete
1.2 Units—The values stated in inch-pound units are to be
D7508/D7508M Specification for Polyolefin Chopped
regarded as standard. The values given in parentheses are
Strands for Use in Concrete
mathematical conversions to SI units that are provided for
E105Practice for Probability Sampling of Materials
information only and are not considered standard.
1.3 This international standard was developed in accor-
3. Terminology
dance with internationally recognized principles on standard-
3.1 Definitions—Fordefinitionsoftermsrelatingtoconcrete
ization established in the Decision on Principles for the
pipe not defined in this standard, see Terminology C822.
Development of International Standards, Guides and Recom-
3.2 Definitions:
mendations issued by the World Trade Organization Technical
3.2.1 D —the D load divided by the long-term
Barriers to Trade (TBT) Committee.
Reload Service
serviceability factor α as determined in accordance with
2. Referenced Documents Section 9.
2
3.2.2 D —the D-Load the pipe is required to sustain
2.1 ASTM Standards:
Service
while in service.
C33/C33MSpecification for Concrete Aggregates
3.2.3 D —the load the pipe is required to support in the
Ult
three-edge bearing test expressed as a D-load.
1
This test method is under the jurisdiction of ASTM Committee C13 on
3.2.4 α—long-term serviceability factor to account for pos-
Concrete Pipe and is the direct responsibility of Subcommittee C13.02 on
Reinforced Sewer and Culvert Pipe.
sible creep in the pipe over time (unitless).
Current edition approved Oct. 1, 2018. Published October 2018. Originally
approved in 2015. Last previous edition approved in 2017 as C1765-17. DOI:
4. Classification
10.1520/C1818-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
4.1 Pipe furnished under this specification shall be desig-
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
nated as Class I, II, III, IV, or V. The corresponding strength
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. requirementsareprescribedinTable1.Specialdesignsforpipe
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1818−18
TABLE 1 Strength Requirements
Pipe Class D D D
S
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1818 − 15 C1818 − 18
Standard Specification for
Synthetic Fiber Reinforced Concrete Culvert, Storm Drain,
1
and Sewer Pipe
This standard is issued under the fixed designation C1818; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope Scope*
1.1 This specification covers synthetic fiber reinforced concrete pipe (Syn-FRCP) of internal diameters 12-48 in., intended to
be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts.
NOTE 1—Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of
bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction
site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of
pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.
NOTE 2—This product is a rigid pipe and it does not depend upon deflection (pipe stiffness) for additional support from the soil.
NOTE 3—This standard requires long-term testing of Syn-FRCP in accordance with Section 9 that goes above and beyond what is typically required
for steel reinforced concrete pipe, in order to evaluate the long-term material strength of the fiber-concrete matrix.
1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are
mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
C33/C33M Specification for Concrete Aggregates
C150/C150M Specification for Portland Cement
C260/C260M Specification for Air-Entraining Admixtures for Concrete
C309 Specification for Liquid Membrane-Forming Compounds for Curing Concrete
C494/C494M Specification for Chemical Admixtures for Concrete
C497 Test Methods for Concrete Pipe, Manhole Sections, or Tile
C595/C595M Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C822 Terminology Relating to Concrete Pipe and Related Products
C989/C989M Specification for Slag Cement for Use in Concrete and Mortars
C1017/C1017M Specification for Chemical Admixtures for Use in Producing Flowing Concrete
C1116/C1116M Specification for Fiber-Reinforced Concrete
D7508/D7508M Specification for Polyolefin Chopped Strands for Use in Concrete
E105 Practice for Probability Sampling of Materials
3. Terminology
3.1 Definitions—For definitions of terms relating to concrete pipe not defined in this standard, see Terminology C822.
3.2 Definitions:
3.2.1 D —the D load divided by the long-term serviceability factor α as determined in accordance with Section 9.
Reload Service
1
This test method is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.02 on Reinforced Sewer and
Culvert Pipe.
Current edition approved Oct. 15, 2015Oct. 1, 2018. Published December 2015October 2018. Originally approved in 2015. Last previous edition approved in 2017 as
C1765-17. DOI: 10.1520/C1818-15.10.1520/C1818-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1818 − 18
3.2.2 D —the D-Load the pipe is required to sustain while in service.
Service
3.2.3 D —the load the pipe is required to support in the three-edge bearing test expressed as a
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.