SCOPE
1.1 This test method describes a laboratory procedure for determining the average nonvolatile content for one- or two-component cold liquid-applied elastomeric waterproofing membranes.
1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 1250 – 93 (Reapproved 1998)
Standard Test Method for
Nonvolatile Content of Cold Liquid-Applied Elastomeric
Waterproofing Membranes
This standard is issued under the fixed designation C 1250; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 6.2 Balance, sensitive to 0.01 g.
6.3 Two Aluminum Weighing Dishes,57by18mm.
1.1 This test method describes a laboratory procedure for
determining the average nonvolatile content for one- or two-
7. Conditioning/Mixing
component cold liquid-applied elastomeric waterproofing
7.1 Unless otherwise specified by those authorizing the
membranes.
tests, standard conditions for all tests are 23 6 2°C (73.4 6
1.2 The values stated in SI units are to be regarded as the
3.6°F) and 50 6 5 % relative humidity.
standard. The values in parentheses are for information only.
7.2 Store all membrane materials to be tested in an un-
1.3 This standard does not purport to address all of the
opened container at standard conditions for at least 24 h before
safety concerns, if any, associated with its use. It is the
any test specimens are prepared.
responsibility of the user of this standard to establish appro-
7.3 Follow the manufacturer’s instructions for mixing and
priate safety and health practices and determine the applica-
preparing membrane materials for testing. Thoroughly mix
bility of regulatory limitations prior to use.
one-component materials before using. Mix two-component
2. Referenced Documents compounds in the ratio recommended by the manufacturer.
2.1 ASTM Standards:
8. Procedure
C 717 Terminology of Building Seals and Sealants
8.1 For each test sample, prepare two test specimens as
3. Terminology follows:
8.1.1 Mark each aluminum weighing dish for identification.
3.1 Definitions—Refer toTerminology C 717 for definitions
Accurately weigh each aluminum weighing dish to the nearest
of compound, elastomeric, and waterproofing, used in this test
0.01 g. Record each mass.
method.
8.1.2 Place an aluminum weighing dish on the balance and
4. Summary of Test Method tare. Add 5.06 0.2 g of compound and spread evenly over the
interior surface area of the dish.
4.1 This test method consists of preparing duplicate
8.1.3 Reweigh the test specimen, combination membrane,
samples, each of known mass, and aging these samples for 72
and dish, and record the mass.
hat70 6 2°C (158 6 3.6°F) in an air-circulating oven.
8.1.4 Repeat 8.1.2 and 8.1.3 for duplicate specimens.
5. Significance and Use
8.1
...
Questions, Comments and Discussion