Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers

ABSTRACT
This specification covers single-cell precast reinforced concrete monolithic box sections for use in the construction of culverts, storm drains, and sewers. The products manufactured in accordance with this specification are designated into two types according to span, rise, and design earth cover. The materials for the designed products include reinforced concrete, cementitious materials, aggregates, steel reinforcements, and optional admixtures and blends. The products manufactured by steam curing, water curing, and membrane curing should have tongue and groove ends of such design that the box sections can be laid together to make a continuous line of box sections.
SCOPE
1.1 This specification covers single-cell precast reinforced concrete box sections cast monolithically and intended to be used for the construction of culverts and for the conveyance of storm water industrial wastes and sewage.
1.2 This specification is the companion to SI Specification C 1433M; therefore, no SI equivalents are shown in this specification.
Note 1—This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete box sections specified herein is cautioned that proper correlation of the loading conditions and the field requirements with the box section specified, and provision for inspection at the construction site, are required.

General Information

Status
Historical
Publication Date
31-Aug-2007
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1433-07a - Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers
English language
25 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 1433 – 07a
Standard Specification for
Precast Reinforced Concrete Monolithic Box Sections for
1
Culverts, Storm Drains, and Sewers
This standard is issued under the fixed designation C 1433; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (ε) indicates an editorial change since the last revision or reapproval.
1. Scope lindrical Concrete Specimens
C 150 Specification for Portland Cement
1.1 This specification covers single-cell precast reinforced
C 309 Specification for Liquid Membrane-Forming Com-
concrete box sections cast monolithically and intended to be
pounds for Curing Concrete
used for the construction of culverts and for the conveyance of
C 497 Test Methods for Concrete Pipe, Manhole Sections,
storm water industrial wastes and sewage.
or Tile
1.2 This specification is the companion to SI Specification
C 595 Specification for Blended Hydraulic Cements
C 1433M; therefore, no SI equivalents are shown in this
C 618 Specification for Coal Fly Ash and Raw or Calcined
specification.
Natural Pozzolan for Use in Concrete
NOTE 1—This specification is primarily a manufacturing and purchas-
C 822 Terminology Relating to Concrete Pipe and Related
ing specification. However, standard designs are included and the criteria
Products
used to develop these designs are given in Appendix X1. The successful
C 989 Specification for Ground Granulated Blast-Furnace
performance of this product depends upon the proper selection of the box
Slag for Use in Concrete and Mortars
section, bedding, backfill, and care that the installation conforms to the
C 1116 Specification for Fiber-Reinforced Concrete and
construction specifications. The purchaser of the precast reinforced
concrete box sections specified herein is cautioned that proper correlation
Shotcrete
3
of the loading conditions and the field requirements with the box section
2.2 AASHTO Standard:
specified, and provision for inspection at the construction site, are
Standard Specifications for Highway Bridges
required.
3. Terminology
2. Referenced Documents
3.1 Definitions—For definitions of terms relating to con-
2
2.1 ASTM Standards:
crete pipe, see Terminology C 822.
A 82/A 82M Specification for Steel Wire, Plain, for Con-
crete Reinforcement
4. Types
A 185/A 185M Specification for Steel Welded Wire Rein-
4.1 Precast reinforced concrete box sections manufactured
forcement, Plain, for Concrete
in accordance with this specification shall be one of two types
A 496/A 496M Specification for Steel Wire, Deformed, for
identified in Table 1 and Table 2, and shall be designated by
Concrete Reinforcement
type, span, rise, and design earth cover.
A 497/A 497M Specification for Steel Welded Wire Rein-
forcement, Deformed, for Concrete
5. Basis of Acceptance
A 615/A 615M Specification for Deformed and Plain
5.1 Acceptability of the box sections produced in accor-
Carbon-Steel Bars for Concrete Reinforcement
dance with Section 7 shall be determined by the results of the
C 31/C 31M Practice for Making and Curing Concrete Test
concrete compressive strength tests described in Section 10,by
Specimens in the Field
the material requirements described in Section 6, and by
C33 Specification for Concrete Aggregates
inspection of the finished box sections.
C 39/C 39M Test Method for Compressive Strength of Cy-
5.2 Box sections shall be considered ready for acceptance
when they conform to the requirements of this specification.
1
This specification is under the jurisdiction of ASTM Committee C13 on
6. Material
Concrete Pipe and is the direct responsibility of Subcommittee C13.07 on
6.1 Reinforced Concrete—The reinforced concrete shall
Acceptance Specifications and Precast Concrete Box Sections.
Current edition approved Sept. 1, 2007. Published October 2007. Originally
consist of cementitious materials, mineral aggregates and
approved in 1999. Last previous edition approved in 2007 as C 1433 – 07.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from American Association of State Highway and Transportation
the ASTM website. Officials (AASHTO), 444 N. Capitol St., NW, Suite 249, Washington, DC 20001.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C 1433 – 07a
water, in which steel has been embedded in such a manner that ment areas in Tables 1 and 2 are based solely on the use of
the steel and concrete act together. welded wire reinforcement, refer to 11.6 if alt
...