ASTM C1902-20
(Specification)Standard Specification for Cellular Glass Insulation Used in Building and Roof Applications
Standard Specification for Cellular Glass Insulation Used in Building and Roof Applications
SCOPE
1.1 This specification covers the general requirements for thermal insulation block composed of rigid cellular glass intended for use in building exterior and interior walls, foundation, floor, ceiling, and roofing applications. The insulation blocks are intended for continuous use at temperatures between 200°F and −50°F (93.3°C and −45.6°C).
1.2 This standard is intended to apply to rigid cellular glass thermal insulation block products that are commercially useful in building exterior and interior walls, foundation, floor, ceiling, and roofing construction. For engineering and design purposes, users need to follow specific product information provided by block manufacturers regarding physical properties, system design considerations and installation recommendations.
1.3 The use of thermal insulation materials covered by this specification is typically regulated by building codes, or other agencies that address fire performance or both. Where required, the fire performance of the material shall be addressed through standard fire test methods established by the appropriate governing documents.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. For conversion to metric units other than those contained in this standard, refer to IEEE/ASTM SI 10.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1902 −20
Standard Specification for
Cellular Glass Insulation Used in Building and Roof
1
Applications
This standard is issued under the fixed designation C1902; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
1.1 This specification covers the general requirements for 2.1 ASTM Standards:
thermal insulation block composed of rigid cellular glass C165TestMethodforMeasuringCompressivePropertiesof
intended for use in building exterior and interior walls, Thermal Insulations
foundation, floor, ceiling, and roofing applications. The insu- C168Terminology Relating to Thermal Insulation
lation blocks are intended for continuous use at temperatures C177Test Method for Steady-State Heat Flux Measure-
between 200°F and −50°F (93.3°C and −45.6°C). ments and Thermal Transmission Properties by Means of
the Guarded-Hot-Plate Apparatus
1.2 This standard is intended to apply to rigid cellular glass
C203Test Methods for Breaking Load and Flexural Proper-
thermal insulation block products that are commercially useful
ties of Block-Type Thermal Insulation
in building exterior and interior walls, foundation, floor,
C240Test Methods for Testing Cellular Glass Insulation
ceiling, and roofing construction. For engineering and design
Block
purposes, users need to follow specific product information
C303Test Method for Dimensions and Density of Pre-
provided by block manufacturers regarding physical
formed Block and Board–Type Thermal Insulation
properties, system design considerations and installation rec-
C390Practice for Sampling and Acceptance of Thermal
ommendations.
Insulation Lots
1.3 The use of thermal insulation materials covered by this
C518Test Method for Steady-State Thermal Transmission
specification is typically regulated by building codes, or other
Properties by Means of the Heat Flow Meter Apparatus
agenciesthataddressfireperformanceorboth.Whererequired,
C1045Practice for Calculating Thermal Transmission Prop-
the fire performance of the material shall be addressed through
erties Under Steady-State Conditions
standard fire test methods established by the appropriate
C1617Practice for Quantitative Accelerated Laboratory
governing documents.
Evaluation of Extraction Solutions Containing Ions
Leached from Thermal Insulation on Aqueous Corrosion
1.4 The values stated in inch-pound units are to be regarded
as the standard. The values given in parentheses are for of Metals
D2126Test Method for Response of Rigid Cellular Plastics
information only. For conversion to metric units other than
those contained in this standard, refer to IEEE/ASTM SI 10. to Thermal and Humid Aging
E84Test Method for Surface Burning Characteristics of
1.5 This standard does not purport to address all of the
Building Materials
safety concerns, if any, associated with its use. It is the
E96/E96MTest Methods for Water Vapor Transmission of
responsibility of the user of this standard to establish appro-
Materials
priate safety, health, and environmental practices and deter-
E136TestMethodforAssessingCombustibilityofMaterials
mine the applicability of regulatory limitations prior to use.
Using a Vertical Tube Furnace at 750°C
1.6 This international standard was developed in accor-
dance with internationally recognized principles on standard-
3. Terminology
ization established in the Decision on Principles for the
3.1 For definitions used in this specification, see Terminol-
Development of International Standards, Guides and Recom-
ogy C168.
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
3.2 Definitions of Terms Specific to This Standard:
1
This specification is under the jurisdiction of ASTM Committee C16 on
2
Thermal Insulation and is the direct responsibility of Subcommittee C16.20 on For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Homogeneous Inorganic Thermal Insulations. contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Current edition approved Nov. 1, 2020. Published December 2020. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/C1902-20. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1902−20
3.2.1 block, n—unfaced cellular glass. 6. Materials and Manufacture
6.1 The block material shall consist of a glass composition
4. Classification
that has been foamed or cellulated under molten conditions,
4.1 Cellular glass insulation cov
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.