ASTM C726-05
(Specification)Standard Specification for Mineral Fiber Roof Insulation Board
Standard Specification for Mineral Fiber Roof Insulation Board
SCOPE
1.1 This specification covers the composition and physical properties of mineral fiber insulation board used above structural roof decks as a base for built-up roofing and single ply membrane systems in building construction.
1.2 The use of thermal insulation materials covered by this specification may be regulated by building codes or other agencies that address fire performance, or both. The fire performance of the material should be addressed through standard fire test methods established by the appropriate governing documents.
1.3 The values stated in inch-pound units are to be regarded as the standard. the values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of the regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 726 – 05
Standard Specification for
1
Mineral Fiber Roof Insulation Board
This standard is issued under the fixed designation C726; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope the Guarded Hot Plate Apparatus
C203 Test Methods for Breaking Load and Flexural Prop-
1.1 This specification covers the composition and physical
erties of Block-Type Thermal Insulation
properties of mineral fiber insulation board used above struc-
C209 Test Methods for Cellulosic Fiber Insulating Board
tural roof decks as a base for built-up roofing and single ply
C390 Practice for Sampling and Acceptance of Preformed
membrane systems in building construction.
2
Thermal Insulation Lots
1.2 The use of thermal insulation materials covered by this
C518 Test Method for Steady-State Heat Flux Measure-
specification may be regulated by building codes or other
ments and Thermal Transmission Properties by Means of
agencies that address fire performance, or both. The fire
the Heat Flow Meter Apparatus
performance of the material should be addressed through
C1363 TestMethodfortheThermalPerformanceofBuild-
standard fire test methods established by the appropriate
ing Assemblies by Means of a Hot Box Apparatus
governing documents.
D312 Specification for Asphalt Used in Roofing
1.3 The values stated in inch-pound units are to be regarded
D450 Specification for Coal-Tar Pitch Used in Roofing,
as the standard. the values given in parentheses are for
Dampproofing, and Waterproofing
information only.
D2126 TestMethodforResponseofRigidCellularPlastics
1.4 This standard does not purport to address all of the
to Thermal and Humid Aging
safety concerns, if any, associated with its use. It is the
E84 Test Method for Surface Burning Characteristics of
responsibility of the user of this standard to establish appro-
Building Materials
priate safety and health practices and determine the applica-
2.3 Other Referenced Documents:
bility of the regulatory limitations prior to use.
CAN/ULC-S102–M88 StandardMethodofTestforSurface
2. Referenced Documents BurningCharacteristicsofBuildingMaterialsandAssem-
3
blies
2.1 The following standards, of the issue in effect on the
date of material purchase, form a part of this specification to
3. Terminology
the extent specified herein:
2
3.1 Definitions—Termsusedinthisspecificationaredefined
2.2 ASTM Standards:
in Terminology C168.
C165 Test Method for Measuring Compressive Properties
of Thermal Insulations
4. Ordering Information
C168 Terminology Relating to Thermal Insulating Materi-
4.1 Orders for material purchased under this specification
als
shall include:
C177 Test Method for Steady-State Heat Flux Measure-
4.1.1 Designation of this specification,
ments and Thermal Transmission Properties by Means of
4.1.2 Product name,
4.1.3 Board dimensions,
1
This specification is under the jurisdiction of ASTM Committee C16 on 4.1.4 Quantity of material, and
Thermal Insulation and is the direct responsibility of Subcommittee C16.20 on
4.1.5 Special packaging or marking, (13.1 and 13.2)if
Homogeneous Inorganic Thermal Insulations.
required.
Current edition approved April 1, 2005. Published April 2005. Originally
approved in 1972. Last previous edition appoved in 2000 as C726–00a.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from Underwriters’ Laboratories of Canada, 7 Crouse Road, Scar-
the ASTM website. borough, Ontario, Canada M1R 3A9.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C726–05
2 2
5. Materials and Manufacture 7.5 Mass per unit area of any board, lb/ft (kg/m ) shall be
within 10% of the value specified by the manufacturer.
5.1 Mineral fiber roof insulation board shall consist of
Averagemassperunitareaofatleast20boardsshallbewithin
mineral fibers with an organic resin or other suitable binder.
5% of the value specified by the manufacturer.
5.2 For built-up roofing or polymer modified bitumen sys-
tems the board shall be faced during manufacture on one
8. Workmanship, Finish, and Appearance
surface with a cover adequate for the application of Specifica-
tion D312 asphalt or Specification D450 coal-tar pitch 8.1 Insulation boards shall not have visible defects that will
adversely affect service qualities.
built-up roo
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.