Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials

SCOPE
1.1 This practice covers the basic principles and operating procedures for using xenon arc light and water apparatus intended to reproduce the weathering effects that occur when materials are exposed to sunlight (either direct or through window glass) and moisture as rain or dew in actual use. This practice is limited to the procedures for obtaining, measuring, and controlling conditions of exposure. A number of exposure procedures are listed in an appendix; however, this practice does not specify the exposure conditions best suited for the material to be tested.
Note 1--Practice G151 describes performance criteria for all exposure devices that use laboratory light sources. This practice replaces Practice G26, which describes very specific designs for devices used for xenon-arc exposures. The apparatus described in Practice G26 is covered by this practice.
1.2 Test specimens are exposed to filtered xenon arc light under controlled environmental conditions. Different types of xenon arc light sources and different filter combinations are described.
1.3 Specimen preparation and evaluation of the results are covered in ASTM methods or specifications for specific materials. General guidance is given in Practice G 151 and ISO 4892-1. More specific information about methods for determining the change in properties after exposure and reporting these results is described in ISO 4582.
1.4 The values stated in SI units are to be regarded as the standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.5.1 Should any ozone be generated from the operation of the lamp(s), it shall be carried away from the test specimens and operating personnel by an exhaust system.
1.6 This practice is technically similar to the following ISO documents: ISO 4892-2, ISO 1134, ISO 105 B02, ISO 105 B04, ISO 105 B05, and ISO 105 B06.

General Information

Status
Historical
Publication Date
09-Aug-2000
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM G155-00ae1 - Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
e1
Designation: G 155 – 00a
Standard Practice for
Operating Xenon Arc Light Apparatus for Exposure of Non-
1
Metallic Materials
This standard is issued under the fixed designation G 155; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1
e NOTE—Table X3.2 was added editorially in May 2001.
1. Scope 1.5.1 Should any ozone be generated from the operation of
the lamp(s), it shall be carried away from the test specimens
1.1 This practice covers the basic principles and operating
and operating personnel by an exhaust system.
procedures for using xenon arc light and water apparatus
1.6 This practice is technically similar to the following ISO
intended to reproduce the weathering effects that occur when
documents: ISO 4892-2, ISO 1134, ISO 105 B02, ISO 105
materials are exposed to sunlight (either direct or through
B04, ISO 105 B05, and ISO 105 B06.
window glass) and moisture as rain or dew in actual use. This
practice is limited to the procedures for obtaining, measuring,
2. Referenced Documents
and controlling conditions of exposure. A number of exposure
2.1 ASTM Standards:
procedures are listed in an appendix; however, this practice
D 3980 Practice for Interlaboratory Testing of Paint and
does not specify the exposure conditions best suited for the
2
Related Materials
material to be tested.
E 691 Practice for Conducting an Interlaboratory Study to
3
NOTE 1—Practice G 151 describes performance criteria for all exposure
Determine the Precision of a Test Method
devices that use laboratory light sources. This practice replaces Practice
G 26 Practice for Operating Light-Exposure Apparatus
G 26, which describes very specific designs for devices used for xenon-arc
(Xenon-Arc Type) With and Without Water for Exposure
exposures. The apparatus described in Practice G 26 iscovered by this
4
of Nonmetallic Materials
practice.
G 113 Terminology Relating to Natural and Artificial
1.2 Test specimens are exposed to filtered xenon arc light
4
Weathering Tests for Nonmetallic Materials
under controlled environmental conditions. Different types of
G 151 Practice for Exposing Nonmetallic Materials in Ac-
xenon arc light sources and different filter combinations are
celerated Test Devices That Use Laboratory Light
described.
4
Sources
1.3 Specimen preparation and evaluation of the results are
2.2 CIE Standards:
covered in ASTM methods or specifications for specific
CIE-Publ. No. 85: Recommendations for the Integrated
materials. General guidance is given in Practice G 151 and ISO
Irradiance and the Spectral Distribution of Simulated
4892-1. More specific information about methods for deter-
5
Solar Radiation for Testing Purposes
mining the change in properties after exposure and reporting
2.3 International Standards Organization Standards:
these results is described in ISO 4582.
ISO 1134, Paint and Varnishes—Artificial Weathering Ex-
1.4 The values stated in SI units are to be regarded as the
posure to Artificial Radiation to Filtered Xenon Arc
standard.
6
Radiation
1.5 This standard does not purport to address all of the
ISO 105 B02, Textiles—Tests for Colorfastness—Part B02
safety concerns, if any, associated with its use. It is the
Colorfastness to Artificial Light: Xenon Arc Fading Lamp
responsibility of the user of this standard to establish appro-
6
Test
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
2
Discontinued 1998. See 1998 Annual Book of ASTM Standards, Vol 06.01.
3
Annual Book of ASTM Standards, Vol 14.02.
1 4
This practice is under the jurisdiction of ASTM Committee G3 on Weathering Annual Book of ASTM Standards, Vol 14.04.
5
and Durability and is the direct responsibility of Subcommittee G03.03 on Available from Secretary, U.S. National Committee, CIE, National Institute of
Simulated and Controlled Exposure Tests. Standards and Technology, Gaithersburg, MD 20899.
6
Current edition approved August 10, 2000. Published November 2000. Origi- Available from American National Standards Institute, 11 W. 42nd St., 13th
nally published as G 155 – 97. Last previous edition G 155 – 00. Floor, New York, NY 10036.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
G 155
ISO 105 B04, Textiles—Tests for Colorfastness—Part B04 5. Significance and Use
Colorfastness to Artificial Weathering: Xenon Arc Fading
5.1 The use of this apparatus is intended to induce property
6
Lamp Test
changes associated with the end use conditions, including the
ISO 105 B05,
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.