ASTM C507M-08a
(Specification)Standard Specification for Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe (Metric)
Standard Specification for Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe (Metric)
ABSTRACT
This specification covers reinforced elliptically shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. Pipe design based on its major axis shall be designated as horizontal and vertical elliptical pipe. The reinforced concrete shall consist of cementitious materials, mineral aggregates, and water, in which steel has been embedded in such a manner that the steel and concrete act together. The combination of cementitious materials used in the concrete shall only be one of the following: Portland cement, Portland blast furnace slag cement, slag modified Portland cement, Portland pozzolan cement, a combination of Portland cement and ground granulated blast-furnace slag, a combination of Portland cement and fly ash, a combination of Portland cement, ground granulated blast-furnace slag, and fly ash. Collated fibrillated virgin polypropylene fibers may be used. Design of pipe such as size, shape, special designs, and area, shall be as listed in the specification. Circumferential, longitudinal, and joint reinforcements shall meet the requirements of this specification. Mixture and curing of pipe shall conform to the requirements of this specification. Compression tests determining concrete compressive strength may be made on either standard rodded concrete cylinders or concrete cylinders compacted and cured in like manner as the pipe, or on cores drilled from the pipe. Pipe may be repaired because of imperfections in manufacture or damage during handling and shall be acceptable if the repaired pipe conforms to the requirements of this specification.
SCOPE
1.1 This specification covers reinforced elliptically shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts.
1.2 Pipe designed for placement with the major axis horizontal shall be designated as “Horizontal Elliptical Pipe.” Pipe designed for placement with the major axis vertical shall be designated as “Vertical Elliptical Pipe.”
1.3 This specification is the SI companion to Specification C 507.
Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 507M – 08a
Standard Specification for
Reinforced Concrete Elliptical Culvert, Storm Drain, and
1
Sewer Pipe (Metric)
This standard is issued under the fixed designation C 507M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope A 497/A 497M Specification for Steel Welded Wire Rein-
forcement, Deformed, for Concrete
1.1 This specification covers reinforced elliptically shaped
A 615/A 615M Specification for Deformed and Plain
concrete pipe to be used for the conveyance of sewage,
Carbon-Steel Bars for Concrete Reinforcement
industrial wastes, storm water, and for the construction of
A 706/A 706M Specification for Low-Alloy Steel De-
culverts.
formed and Plain Bars for Concrete Reinforcement
1.2 Pipe designed for placement with the major axis hori-
C33 Specification for Concrete Aggregates
zontal shall be designated as “Horizontal Elliptical Pipe.” Pipe
C 150 Specification for Portland Cement
designed for placement with the major axis vertical shall be
C 260 Specification forAir-EntrainingAdmixtures for Con-
designated as “Vertical Elliptical Pipe.”
crete
1.3 This specification is the SI companion to Specification
C 309 Specification for Liquid Membrane-Forming Com-
C 507.
pounds for Curing Concrete
NOTE 1—This specification is a manufacturing and purchase specifica-
C 494/C 494M Specification for Chemical Admixtures for
tion only, and does not include requirements for bedding, backfill, or the
Concrete
relationship between field load condition and the strength classification of
C 497M Test Methods for Concrete Pipe, Manhole Sec-
pipe. However, experience has shown that the successful performance of
tions, or Tile [Metric]
this product depends upon the proper selection of the class of pipe, type
of bedding and backfill, and care that the installation conforms to C 595 Specification for Blended Hydraulic Cements
construction specifications. The owner of the reinforced concrete pipe
C 618 Specification for Coal Fly Ash and Raw or Calcined
specified herein is cautioned that he must correlate the field requirements
Natural Pozzolan for Use in Concrete
with the class of pipe specified and provide inspection at the construction
C 822 Terminology Relating to Concrete Pipe and Related
site.
Products
C 989 Specification for Ground Granulated Blast-Furnace
2. Referenced Documents
Slag for Use in Concrete and Mortars
2
2.1 ASTM Standards:
C 1017/C 1017M Specification for Chemical Admixtures
A 36/A 36M Specification for Carbon Structural Steel
for Use in Producing Flowing Concrete
A 82/A 82M Specification for Steel Wire, Plain, for Con-
C 1116 Specification for Fiber-Reinforced Concrete and
crete Reinforcement
Shotcrete
A 185/A 185M Specification for Steel Welded Wire Rein-
forcement, Plain, for Concrete
3. Terminology
A 496/A 496M Specification for Steel Wire, Deformed, for
3.1 Definitions—For definitions of terms relating to con-
Concrete Reinforcement
crete pipe, see Terminology C 822.
4. Classification
1
This specification is under the jurisdiction of ASTM Committee C13 on 4.1 Pipe manufactured according to this specification shall
Concrete Pipe and is the direct responsibility of Subcommittee C13.02 on
be of five classes each for horizontal elliptical and vertical
Reinforced Sewer and Culvert Pipe.
elliptical pipe with identification as follows:
Current edition approved April 15, 2008. Published May 2008. Originally
Horizontal Elliptical Pipe Vertical Elliptical Pipe
approved in 1980. Last previous edition approved in 2008 as C 507M – 08.
2
Class HE-A Class VE-II
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Class HE-I Class VE-III
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Class HE-II Class VE-IV
Standards volume information, refer to the standard’s Document Summary page on
Class HE-III Class VE-V
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C 507M – 08a
from the wall of the pipe for each mix design that is used on an
Class HE-IV Class VE-VI
order; and by visual inspection of the finished pipe to deter-
4.2 The strength requirements for horizontal elliptical pipe
mine its conformance with the accepted design prescribed and
are prescribed in Table 1 and for vertical elliptical pipe are
its freedom from defects.
prescribed in Table 2.
5.1.2 Acceptance on the Basis of Material Test and Inspec-
tion of Manufactured Pipe for Defects and Imperfec
...