Standard Specification For Expanded Polystyrene ("EPS") Thermal Insulation Boards For Use In Exterior Insulation and Finish Systems ("EIFS")

ABSTRACT
This specification is for flat, uncoated expanded polystyrene thermal insulation boards for use in exterior insulation and finish systems (EIFS). The thermal insulation boards shall be made of a particular percentage of virgin EPS . Properties of thermal insulation boards such as length, width, thickness, edge trueness, face flatness, and squareness shall be observed.
SCOPE
1.1 This specification is for flat, uncoated expanded polystyrene thermal insulation boards for use in exterior insulation and finish systems (EIFS).
1.2 EIFS producers may have requirements in addition to, or different than, those in this specification.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for informational purposes only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
14-Jun-2005
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM E2430-05 - Standard Specification For Expanded Polystyrene ("EPS") Thermal Insulation Boards For Use In Exterior Insulation and Finish Systems ("EIFS")
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:E2430 −05
StandardSpecification For
Expanded Polystyrene (“EPS”) Thermal Insulation Boards
For Use In Exterior Insulation and Finish Systems (“EIFS”)
This standard is issued under the fixed designation E2430; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 4. Requirements
1.1 This specification is for flat, uncoated expanded poly- 4.1 The thermal insulation boards shall meet the following
styrene thermal insulation boards for use in exterior insulation
requirements.
and finish systems (EIFS).
4.1.1 Insulation boards shall meet the properties listed in
Table 1 of Specification C578 for Type I.
1.2 EIFS producers may have requirements in addition to,
4.1.2 Insulation boards shall be made of 100 % virgin EPS.
or different than, those in this specification.
4.1.3 Length: 1219 mm (48 in.) 61.6 mm (6 ⁄16 in.)
1.3 The values stated in SI units are to be regarded as the
4.1.4 Width: 610 mm (24 in.) 61.6 mm (6 ⁄16 in.)
standard.Thevaluesgiveninparenthesesareforinformational
4.1.5 Thickness:
purposes only.
3 1
4.1.5.1 Minimum 20 mm ( ⁄4 in.) + 1.6 mm ( ⁄16 in.)
1.4 This standard does not purport to address all of the
4.1.5.2 Maximum: as specified
safety concerns, if any, associated with its use. It is the
4.1.6 Edge Trueness: When measured with a straight edge,
responsibility of the user of this standard to establish appro-
edges shall not deviate more that 0.8 mm ( ⁄32 in.) in 305 mm
priate safety and health practices and determine the applica-
(12 in.)
bility of regulatory limitations prior to use.
4.1.7 Face Flatness: When measured across the face with a
straight edge, the maximum deviation for the straight edge
2. Referenced Documents
shall not exceed more than 0.8 mm ( ⁄32 in.)
2.1 ASTM Standards:
4.1.8 Squareness: When measured on the large flat face
C578 Specification for Rigid, Cellular Polystyrene Thermal
from one corner to the opposing corner, the dimensional
Insulation
variations shall not exceed more than 0.8 mm ( ⁄32 in.) in 305
mm (12 in.).
3. Ordering Information
4.1.9 Aging. Prior to cutting into individual boards, the
3.1 The following information shall be provided when
insulation billet shall remain in one of the following states:
shipping materials under this specification.
4.1.9.1 For a minimum of 6 week at ambient temperatures
3.1.1 Thickness, width and length,
and humidity conditions of the storage locations.
3.1.2 Number of pieces,
4.1.9.2 For a minimum of five (5) days at a constant
3.1.3 Shipping address,
temperature of 60°C (140°F).
3.1.4 Required delivery date,
4.1.9.3 For a minimum of 12 days at the existing tempera-
3.1.5 Billing information,
ture and humidity conditions of the storage location when
3.1.6 Certificate of compliance with this specification, and
thermal insulation boards are manufactured using low pentane
3.1.7 EIFS producer name and product name for which
EPS resin (< 4.5 % pentane) and vacuum molding technology.
insulation is to be used.
4.1.9.4 For a minimum of 18 days at existing temperature
and humidity conditions of the storage location when thermal
insulation boards are manufactured using full pentane resin
This specification is under the jurisdiction of ASTM Committee E06 on
(nominal 6 % pentane) and using vacuum molding technology.
Performance of Buil
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.