Standard Test Method for Measurement of Solids in Water

SCOPE
1.1 This test method covers the measurement of the solids content in water for use as mixing water in ready-mixed concrete and the measurement of its density. Solids content is expressed in terms of parts per million (ppm) or in terms of percent by mass of the water sample.
1.2 The values stated in SI units are to be regarded as standard; inch-pound units are shown in parenthesis for information only.
1.3 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Jul-2004
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C1603-04e1 - Standard Test Method for Measurement of Solids in Water
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
e1
Designation:C1603–04
Standard Test Method for
1
Measurement of Solids in Water
This standard is issued under the fixed designation C 1603; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1
e NOTE—Equation 6 was revised editorially in December 2004.
1. Scope 3.2 The method provides a means to determine the relation-
ship between the density and solids content of water for
1.1 This test method covers the measurement of the solids
compliance with solids content limits of mixing water such as
content in water for use as mixing water in ready-mixed
in Specification C 1602/C 1602M.
concrete and the measurement of its density. Solids content is
3.3 During production of concrete, the water property mea-
expressed in terms of parts per million (ppm) or in terms of
sured is its density, which can then be used to estimate the
percent by mass of the water sample.
solids content from procedures described in this test method.
1.2 The values stated in SI units are to be regarded as
3.4 To develop a correlation between the density and solids
standard; inch-pound units are shown in parenthesis for infor-
content of water, water samples should be tested that cover the
mation only.
range of solids concentrations anticipated during production.
1.3 The text of this standard references notes and footnotes
that provide explanatory material. These notes and footnotes
4. Apparatus
(excluding those in tables and figures) shall not be considered
4.1 Density Measure: A cylindrical container (Note 1) with
as requirements of the standard.
a volume of 200 6 25 mL (7 6 1 fl. oz.) with a glass or
1.4 This standard does not purport to address all of the
Plexiglasyplatethatisplacedoverit.Theglassorplasticplate
safety concerns, if any, associated with its use. It is the
1 1
shall be at least 6 mm ( ⁄4 in.) thick and 40 mm (1 ⁄2-in.) larger
responsibility of the user of this standard to establish appro-
than the outer diameter of the measure. The top of the density
priate safety and health practices and to determine the
measure shall be flat such that it does not leak when the plate
applicability of regulatory limitations prior to use.
is placed over it.
2. Referenced Documents
NOTE 1—Acommonlyavailablesmallersizemasonjarwithtopground
2
2.1 ASTM Standards: smooth is acceptable.
C 29/ C 29M Test Method for Bulk Density (Unit Weight)
4.2 The volume of the density measure shall be determined
and Voids in Aggregate
to nearest 0.1 mL in accordance with procedures used for
C 670 Practice for Preparing Precision and Bias Statements
calibrating air or density measures, as in Test Method C 29/
for Test Methods for Construction Materials
C 29M.
C 1602/C 1602M Standard Specification for Mixing Water
4.3 A microwave oven with at least 900 W of power
used in the Production of Hydraulic Cement Concrete
capacity.
4.4 Amicrowave-safe glass dish large enough to contain the
3. Significance and Use
water sample and fiberglass cloth (See Note 2).
3.1 This method is used to determine the solids content of
NOTE 2—A 450 3 450 3 25 mm (9 3 9 3 1 in.) Pyrexy dish is
mixing water used to produce concrete when one or more of
acceptable. Fiberglass cloth commonly used with fiberglass resin for boat
the water sources is wash water from concrete production
or auto body repair is found in most hardware stores.
operations or water that contains solids when batched as
4.5 A balance or scale with a minimum capacity of 2000 g
mixing water in concrete.
accurate to 0.1 g
4.6 A rubber syringe
1
This test method is under the jurisdiction of ASTM Committee C09 on
Concrete and ConcreteAggregates and is the direct responsibility of Subcommittee
5. Measurement of Density
C09.40 on Ready-Mixed Concrete.
Current edition approved Aug. 1, 2004. Published September 2004.
5.1 Obtain the mass of the empty density measure and plate
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
to the nearest 0.1g.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
e1
C1603–04
5.2 Ifthewatercontainssolidsinsuspension,ensurethatthe densityonaparticularproductiondaycanbeusedtodetermine
water is sampled while the water source is being agitated.Take the solids content of the water.
a representative sample of water and fill the density measure to
S 5 A 1 B 3 D (4)
ppm W
overflowing. Slide the c
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.