Standard Specification for Cast Iron Soil Pipe and Fittings

ABSTRACT
This specification covers cast gray iron soil pipe and fittings for use in gravity flow plumbing, drain, waste and vent sanitary, and storm water applications. These pipe and fittings are not intended for pressure applications. The cast iron shall be produced by an established commercial method that provides control over chemical and physical properties. Castings shall be sound, true to pattern, and of compact close grain that permits drilling and cutting by ordinary methods and its interior surface shall be reasonably smooth and free from defects. Ferrous scrap, pig iron, and any recycled ferrous material to be used in the melting operation shall be screened for radioactivity. Tension test shall include breaking load, machined diameter, and tensile strength. Chemical test shall conform to the chemical composition requirements prescribed for phosphorous, sulfur, chromium, titanium, aluminum, lead, and carbon equivalent. Dimension requirements for hub, spigot, barrel, grooves, water seal and trap, and threads of the pipe and fittings are detailed. The pipe and fittings shall be uniformly coated with a material suitable for the purpose.
SCOPE
1.1 This specification covers cast iron soil pipe and fittings for use in gravity flow plumbing, drain, waste and vent sanitary, and storm water applications. It establishes standards covering material, manufacture, mechanical and chemical properties, coating, test methods, inspection, certification, product markings, dimensions, and dimensional tolerances for extra heavy and service cast iron soil pipe and fittings. These pipe and fittings are not intended for pressure applications as the selection of the proper size for sanitary drain, waste, vent, and storm drain systems allows free air space for gravity drainage.
1.2 This specification covers pipe and fittings of the following patterns and, when so designated, shall apply to any other patterns that conform with the applicable requirements given in this specification.
1.2.1 Pipe:
  Tables Extra heavy, 2½ ft (0.75 m), 3½ft (1.0 m), 5 ft (1.5 m), 10 ft (3.0 m) lengths
1, 2
  Service, 2½ ft (0.75 m), 3½ft (1.0 m), 5 ft (1.5 m), 10 ft (3.0 m)
1, 2
  Outside dimensions (for detailing)
X1.1
1.2.2 Fittings:
  Tables ¼ bends; long ¼ bends
3, 4
  ¼ bends, long low-hub
5
  ¼ bends, low heel; high heel
6, 7
  ¼ bends, short sweep; long sweep
8
  ¼ bends, reducing long sweep
9
  1/5 bends
10
  1/6 bends
10
  1/8 bends; long 1/8 bends
11
  1/16 bends
  11
  Y branches
12, 13
  Y branches, combination 1/8 bends, single
14
  Y branches, combination 1/8 bends, double
14
  Sanitary T branches, single
15
  Sanitary T branches, double
15
  Sanitary T branches, cleanout
16
  Tapped sanitary T branches, single
17
  Tapped sanitary T branches, double
17
  T branches, single and double
18
  Tapped T branches, single
19
  Tapped T branches, double
19
  T branches, cleanout
20
  -45° offset fitting
21
  Double hubs
22
  Long double hubs
22
  Reducers
23
  Increasers
24, 25
  P traps
26, 27
  Deep seal P traps
28
  Running traps
29
  Screw plugs (brass)
30
  Blind plugs
31
  Iron-body ferrules
32
  Side inlets
Fig. 3
  Closet bends
33
  Tapping bosses
34
  Reducing ¼ bend SV
35
  Combination Y and 1/8 bend
36
  ‘H’ branch fitting
37
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

General Information

Status
Historical
Publication Date
30-Apr-2008
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM A74-08 - Standard Specification for Cast Iron Soil Pipe and Fittings
English language
44 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM A74-08 - Standard Specification for Cast Iron Soil Pipe and Fittings
English language
44 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Endorsed by the
Designation: A 74 – 08 Cast Iron Soil Pipe Institute
American Association State
Highway and Transportation Officials Standard
AASHTO No.: M 263-77
Standard Specification for
1
Cast Iron Soil Pipe and Fittings
ThisstandardisissuedunderthefixeddesignationA 74;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope
Tables
1
Y branches, combination ⁄8 bends, double 14
1.1 This specification covers cast iron soil pipe and fittings
Sanitary T branches, single 15
for use in gravity flow plumbing, drain, waste and vent
Sanitary T branches, double 15
Sanitary T branches, cleanout 16
sanitary, and storm water applications. It establishes standards
Tapped sanitary T branches, single 17
covering material, manufacture, mechanical and chemical
Tapped sanitary T branches, double 17
properties, coating, test methods, inspection, certification, T branches, single and double 18
Tapped T branches, single 19
product markings, dimensions, and dimensional tolerances for
Tapped T branches, double 19
extra heavy and service cast iron soil pipe and fittings. These
T branches, cleanout 20
pipe and fittings are not intended for pressure applications as
-45° offset fitting 21
Double hubs 22
the selection of the proper size for sanitary drain, waste, vent,
Long double hubs 22
and storm drain systems allows free air space for gravity
Reducers 23
drainage. Increasers 24, 25
P traps 26, 27
1.2 This specification covers pipe and fittings of the follow-
Deep seal P traps 28
ing patterns and, when so designated, shall apply to any other
Running traps 29
patternsthatconformwiththeapplicablerequirementsgivenin Screw plugs (brass) 30
Blind plugs 31
this specification.
Iron-body ferrules 32
1.2.1 Pipe:
Side inlets Fig. 3
Closet bends 33
Tapping bosses 34
Tables
1
Reducing ⁄4 bend SV 35
1 1
Extra heavy, 2 ⁄2 ft (0.75 m), 3 ⁄2 ft (1.0 m), 5 ft 1, 2
1
Combination Y and ⁄8 bend 36
(1.5 m), 10 ft (3.0 m) lengths
‘H’ branch fitting 37
1 1
Service, 2 ⁄2 ft (0.75 m), 3 ⁄2 ft (1.0 m), 5 ft (1.5 1, 2
m),10ft(3.0m)
Outside dimensions (for detailing) X1.1
1.3 The values stated in inch-pound units are to be regarded
as standard. The values given in parentheses are mathematical
1.2.2 Fittings:
conversions to SI units that are provided for information only
and are not considered standard.
Tables
1 1
⁄4 bends; long ⁄4 bends 3, 4
1
⁄4 bends, long low-hub 5
2. Referenced Documents
1
⁄4 bends, low heel; high heel 6, 7
2
2.1 ASTM Standards:
1
⁄4 bends, short sweep; long sweep 8
1
⁄4 bends, reducing long sweep 9
A 48/A 48M Specification for Gray Iron Castings
1
⁄5 bends 10
A 644 Terminology Relating to Iron Castings
1
⁄6 bends 10
1 1 D 1248 Specification for Polyethylene Plastics Extrusion
⁄8 bends; long ⁄8 bends 11
1
⁄16 bends 11
Materials for Wire and Cable
Y branches 12, 13
E8 Test Methods for Tension Testing of Metallic Materials
1
Y branches, combination ⁄8 bends, single 14
E 2349 Practice for Safety Requirements in Metal Casting
Operations: Sand Preparation, Molding, and Core Making;
1
This specification is under the jurisdiction of ASTM Committee A04 on Iron
2
Castings and is the direct responsibility of Subcommittee A04.12 on Pipes and For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Tubes. contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Current edition approved May 1, 2008. Published June 2008. Originally Standards volume information, refer to the standard’s Document Summary page on
approved in 1917. Last previous edition approved in 2006 as A 74 – 06. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
A74–08
Melting and Pouring; and Cleaning and Finishing 5. Mechanical Properties
3
2.2 Federal Standard:
5.1 Mechanical Tests for Gray Iron—The manufacturer
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
shall perform tests to determine mechanical properties of the
3
2.3 Military Standard:
gray iron used in the manufacture of gray iron soil pipe and
MIL-STD-129 Marking for Shipment and Storage
fittings. Tension test specimens shall be employed. The manu-
4
2.4 ANSI/ASME Standard:
facturer shall maintain a record of mechanical tests for a
B1.20 Pipe Threads
minimum of 7 years.
5.1.1 Tensile Strength Test—The tensile strength shall be
3. Terminology
not less than 21 000 psi (145 MPa).
3.1 Definitions of Terms Specific to This Standard:
5.1.2 Tension test reports shall include breaking loa
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Endorsed by the
Designation:A74–06 Designation: A 74 – 08 Cast Iron Soil Pipe Institute
American Association State
Highway and Transportation Officials Standard
AASHTO No.: M 263-77
Standard Specification for
1
Cast Iron Soil Pipe and Fittings
ThisstandardisissuedunderthefixeddesignationA 74;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope
1.1 This specification covers cast iron soil pipe and fittings for use in gravity flow plumbing, drain, waste and vent sanitary, and
stormwaterapplications.Itestablishesstandardscoveringmaterial,manufacture,mechanicalandchemicalproperties,coating,test
methods, inspection, certification, product markings, dimensions, and dimensional tolerances for extra heavy and service cast iron
soil pipe and fittings. These pipe and fittings are not intended for pressure applications as the selection of the proper size for
sanitary drain, waste, vent, and storm drain systems allows free air space for gravity drainage.
1.2 Thisspecificationcoverspipeandfittingsofthefollowingpatternsand,whensodesignated,shallapplytoanyotherpatterns
that conform with the applicable requirements given in this specification.
1.2.1 Pipe:
Tables
1 1
Extra heavy, 2 ⁄2 ft (0.75 m), 3 ⁄2 ft (1.0 m), 5 ft 1, 2
(1.5 m), 10 ft (3.0 m) lengths
1 1
Service, 2 ⁄2 ft (0.75 m), 3 ⁄2 ft (1.0 m), 5 ft (1.5 1, 2
m),10ft(3.0m)
Outside dimensions (for detailing) X1.1
1.2.2 Fittings:
Tables
1 1
⁄4 bends; long ⁄4 bends 3, 4
1
⁄4 bends, long low-hub 5
1
⁄4 bends, low heel; high heel 6, 7
1
⁄4 bends, short sweep; long sweep 8
1
⁄4 bends, reducing long sweep 9
1
⁄5 bends 10
1
⁄6 bends 10
1 1
⁄8 bends; long ⁄8 bends 11
1
⁄16 bends 11
Y branches 12, 13
1
Y branches, combination ⁄8 bends, single 14
1
Y branches, combination ⁄8 bends, double 14
Sanitary T branches, single 15
Sanitary T branches, double 15
Sanitary T branches, cleanout 16
Tapped sanitary T branches, single 17
Tapped sanitary T branches, double 17
T branches, single and double 18
Tapped T branches, single 19
Tapped T branches, double 19
T branches, cleanout 20
-45° offset fitting 21
Double hubs 22
Long double hubs 22
Reducers 23
Increasers 24, 25
P traps 26, 27
1
This specification is under the jurisdiction of ASTM Committee A04 on Iron Castings and is the direct responsibility of Subcommittee A04.12 on Pipes and Tubes.
Current edition approved Aug. 15, 2006. Published August 2006. Originally approved in 1917. Last previous edition approved in 2005 as A74–05.
Current edition approved May 1, 2008. Published June 2008. Originally approved in 1917. Last previous edition approved in 2006 as A 74 – 06.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
A74–08
Tables
Deep seal P traps 28
Running traps 29
Screw plugs (brass) 30
Blind plugs 31
Iron-body ferrules 32
Side inlets Fig. 3
Closet bends 33
Tapping bosses 34
1
Reducing ⁄4 bend SV 35
1
Combination Y and ⁄8 bend 36
‘H’ branch fitting 37
1.3The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information
only. Metric conversions inTables 1 and 2 are to two decimal places; all other metric conversions are rounded to the nearest whole
number.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
2. Referenced Documents
2
2.1 ASTM Standards:
A 48/A 48M Specification for Gray Iron Castings
A 644 Terminology Relating to Iron Castings
D 1248 Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable
E 8 Test Methods for Tension Testing of Metallic Materials
E 2349 Practice for Safety Requirements in Metal Casting Operations: Sand Preparation, Molding, and Core Making; Melting
and Pouring; and Cleaning and Finishing
3
2.2 Federal Standard:
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
3
2.3 Military Standard:
MIL-STD-129 Marking for Shipment and Storage
4
2.4 ANSI/ASME Standard:
B1.20 Pipe Threads
3. Terminology
3.1 Definitions of Terms Specific to This Standard:
3.2 manufacturer, n—the entity that casts the pipe an
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.