Classification for Rating Sound Insulation

SIGNIFICANCE AND USE
These single-number ratings correlate in a general way with subjective impressions of sound transmission for speech, radio, television, and similar sources of noise in offices and buildings. This classification method is not appropriate for sound sources with spectra significantly different from those sources listed above. Such sources include machinery, industrial processes, bowling allies, power transformers, musical instruments, many music systems, and transportation noises such as motor vehicles, aircraft and trains. For these sources, accurate assessment of sound transmission requires a detailed analysis in frequency bands. A single-number sound transmission rating for building façade elements is given in Classification E1332.
The single-number ratings obtained can be used to compare the potential sound insulation of partitions or floors tested in laboratory conditions (STC) or the actual sound isolation between different suites in buildings (NNIC, NIC). The rating for a partition built and tested in a building may be lower than that obtained for a partition tested in a laboratory because of flanking transmission or construction errors.
Note 1—A similar rating procedure, described in ISO 717, provides single figure sound insulation ratings with a frequency range that extends from 100 to 3150 Hz with no maximum deficiency specified at individual frequencies. For most partitions, the two ratings differ by only one or two points.
SCOPE
1.1 This classification covers methods of calculating single-number acoustical ratings for laboratory and field measurements of sound attenuation obtained in one-third octave bands.
1.2 The name given to the single-number rating is assigned by the test method that invokes this classification.
1.3 Test methods that invoke this classification include:
1.3.1 Test Method E90—The single-number rating is called sound transmission class (STC).
1.3.2 Test Method E336—Single-number ratings are field sound transmission class (FSTC), noise isolation class (NIC), and normalized noise isolation class (NNIC).
1.3.3 Test Method E596—The single-number rating is called noise isolation class (NIC).
1.3.4 Test Method E1414—The single-number rating is called ceiling attenuation class (CAC).
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

General Information

Status
Historical
Publication Date
31-Aug-2010
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E413-10 - Classification for Rating Sound Insulation
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM E413-10 - Classification for Rating Sound Insulation
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:E413 −10
Classificationfor
1
Rating Sound Insulation
This standard is issued under the fixed designation E413; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope E1332 Classification for Rating Outdoor-Indoor Sound At-
tenuation
1.1 This classification covers methods of calculating single-
E1414 Test Method for Airborne Sound Attenuation Be-
number acoustical ratings for laboratory and field measure-
tween Rooms Sharing a Common Ceiling Plenum
ments of sound attenuation obtained in one-third octave bands.
3
2.2 ISO Standard:
1.2 The name given to the single-number rating is assigned
ISO 717 Rating of Sound Insulation for Dwellings
by the test method that invokes this classification.
3. Terminology
1.3 Test methods that invoke this classification include:
1.3.1 Test Method E90—The single-number rating is called
3.1 The following terms used in this classification are
sound transmission class (STC).
defined in Terminology C634:
1.3.2 Test Method E336—Single-number ratings are field
airborne sound,
sound transmission class (FSTC), noise isolation class (NIC),
field sound transmission class,
and normalized noise isolation class (NNIC).
level,
1.3.3 TestMethodE596—Thesingle-numberratingiscalled
noise isolation class,
noise isolation class (NIC).
noise reduction,
1.3.4 Test Method E1414—The single-number rating is
normalized noise isolation class,
called ceiling attenuation class (CAC).
one-third octave band,
sound insulation,
1.4 The values stated in SI units are to be regarded as
sound isolation, and
standard. No other units of measurement are included in this
sound transmission loss.
standard.
4. Significance and Use
2. Referenced Documents
4.1 These single-number ratings correlate in a general way
2
2.1 ASTM Standards:
with subjective impressions of sound transmission for speech,
C634 Terminology Relating to Building and Environmental
radio, television, and similar sources of noise in offices and
Acoustics
buildings. This classification method is not appropriate for
E90 Test Method for Laboratory Measurement of Airborne
sound sources with spectra significantly different from those
Sound Transmission Loss of Building Partitions and
sources listed above. Such sources include machinery, indus-
Elements
trial processes, bowling allies, power transformers, musical
E336 Test Method for Measurement of Airborne Sound
instruments, many music systems, and transportation noises
Attenuation between Rooms in Buildings
such as motor vehicles, aircraft and trains. For these sources,
E596 Test Method for Laboratory Measurement of Noise
accurate assessment of sound transmission requires a detailed
Reduction of Sound-Isolating Enclosures
analysis in frequency bands. A single-number sound transmis-
sion rating for building façade elements is given in Classifica-
tion E1332.
1
This classification is under the jurisdiction of ASTM Committee E33 on
4.2 The single-number ratings obtained can be used to
Building and Environmental Acoustics and is the direct responsibility of Subcom-
mittee E33.03 on Sound Transmission.
compare the potential sound insulation of partitions or floors
Current edition approved Sept. 1, 2010. Published October 2010. Originally
tested in laboratory conditions (STC) or the actual sound
approved in 1970. Last previous edition approved in 2004 as E413 – 04. DOI:
isolation between different suites in buildings (NNIC, NIC).
10.1520/E0413-10.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
the ASTM website. 4th Floor, New York, NY 10036, http://www.ansi.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E413−10
The rating for a partition built and tested in a building may be less than the reference contour this is a deficiency; only
lower than that obtained for a partition tested in a laboratory deficiencies are counted in the fitting procedure. Continue to
because of flanking transmission or construction errors. increase the reference contour values to the highest level that
NOTE 1—A similar rating procedure, described in ISO 717, provides
will satisfy the following conditions:
single figure sound insulation ratings with a frequency range
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E413 – 10
Classification for
1
Rating Sound Insulation
This standard is issued under the fixed designation E413; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope
1.1 This classification covers methods of calculating single-number acoustical ratings for laboratory and field measurements of
sound attenuation obtained in one-third octave bands.
1.2 The name given to the single-number rating is assigned by the test method that invokes this classification.
1.3 Test methods that invoke this classification include:
1.3.1 Test Method E90—The single-number rating is called sound transmission class (STC).
1.3.2 Test Method E336—Single-number ratings are field sound transmission class (FSTC), noise isolation class (NIC), and
normalized noise isolation class (NNIC).
1.3.3 Test Method E596—The single-number rating is called noise isolation class (NIC).
1.3.4 Test Method E1414—The single-number rating is called ceiling attenuation class (CAC).
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
2. Referenced Documents
2
2.1 ASTM Standards:
C634 Terminology Relating to Building and Environmental Acoustics
E90 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
E336 Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
E596 Test Method for Laboratory Measurement of Noise Reduction of Sound-Isolating Enclosures
E1332 Classification for Rating Outdoor-Indoor Sound Attenuation
E1414 Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum
3
2.2 ISO Standard:
ISO 717 Rating of Sound Insulation for Dwellings
3. Terminology
3.1 The following terms used in this classification are defined in Terminology C634:
airborne sound,
field sound transmission class,
level,
noise isolation class,
noise reduction,
normalized noise isolation class,
one-third octave band,
sound insulation,
sound isolation, and
sound transmission loss.
4. Significance and Use
4.1 These single-number ratings correlate in a general way with subjective impressions of sound transmission for speech, radio,
1
This classification is under the jurisdiction ofASTM Committee E33 on Building and EnvironmentalAcoustics and is the direct responsibility of Subcommittee E33.03
on Sound Transmission.
Current edition approved Sept. 1, 2010. Published September 2010. Originally approved in 1970. Last previous edition approved in 2004 as E413 – 04. DOI:
10.1520/E0413-10.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book ofASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
E413 – 10
television,andsimilarsourcesofnoiseinofficesandbuildings.Thisclassificationmethodisnotappropriateforsoundsourceswith
spectrasignificantlydifferentfromthosesourceslistedabove.Suchsourcesincludemachinery,industrialprocesses,bowlingallies,
power transformers, musical instruments, many music systems, and transportation noises such as motor vehicles, aircraft and
trains. For these sources, accurate assessment of sound transmission requires a detailed analysis in frequency bands. A
single-number sound transmission rating for building façade elements is given in Classification E1332.
4.2 The single-number ratings obtained can be used to compare the potential sound insulation of partitions or floors tested in
laboratory conditions (STC) or the actual sound isolation between different suites in buildings (NNIC, NIC). The rating for a
partition built and tested in a building may be lower than that obtained for a partition tested in a laboratory because of flanking
transmission or construction errors.
NOTE 1—A similar rating procedure, described in ISO 717, provides single figure sound insulation ratings with a frequ
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.