Standard Practice for Construction of Chain-Link Tennis Court Fence

SCOPE
1.1 This practice covers fencing around tennis courts, built from various types of chain-link fabric and framework materials, and installation practices for same.  
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Jan-2001
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM F969-01 - Standard Practice for Construction of Chain-Link Tennis Court Fence
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F 969–01
Standard Practice for
1
Construction of Chain-Link Tennis Court Fence
This standard is issued under the fixed designation F 969; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope Other Conforming Organic Polymer-Coated Steel Tension
2
Wire Used with Chain-Link Fence
1.1 This practice covers fencing around tennis courts, built
from various types of chain-link fabric and framework mate-
3. Terminology
rials, and installation practices for same.
3.1 Definitions—See Definitions F 552 for definitions of
1.2 This standard does not purport to address all of the
terms used in this practice.
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
4. Summary of Practice
priate safety and health practices and determine the applica-
4.1 This practice is intended primarily to guide those
bility of regulatory limitations prior to use.
responsible for or concerned with the design and installation of
2. Referenced Documents chain-link fencing around tennis courts.
4.2 This practice does not intend to preclude any practice
2.1 ASTM Standards:
that has proven equal to or given better performance under
A 392 Specification for Zinc-Coated Steel Chain-Link
2 varying conditions such as location, weather, intended use, etc.
Fence Fabric
A 491 Specification for Aluminum-Coated Steel Chain-
5. Significance and Use
2
Link Fence Fabric
5.1 Theintendeduseofthispracticeisfor10-or12-ft(3050
A 824 Specification for Metallic-Coated Steel Marcelled
2 or 3660 mm) high chain-link fencing as complete enclosures
Tension Wire for Use with Chain-Link Fence
2 around single or multiple tennis courts, or as backstops at
F 552 DefinitionsofTermsRelatingtoChainLinkFencing
2 either end of tennis courts.
F 567 Practice for Installation of Chain-Link Fence
2 5.2 This practice is not intended for applications where
F 626 Specification for Fence Fittings
fencing higher than 12 ft (3660 mm) is desired for a special
F 668 Specification for Poly(Vinyl Chloride) (PVC) and
application.
Other Organic Polymer-Coated Steel Chain-Link Fence
5.3 Caution Regarding Windscreens— If wind screens are
2
Fabric
to be installed at the time of fence erection or at a later time, it
F 900 Specification for Industrial and Commercial Swing
is advisable to use stronger framework and parts and closer
2
Gates
spacing of posts or back bracing depending upon the type of
F 934 Specification for Standard Colors for Polymer-
screening material to be used, area of fence to be covered, and
2
Coated Chain Link Fence Materials
local wind conditions.
F 1043 Specification for Strength and Protective Coatings
2
on Metal Industrial Chain Link Framework
6. Classification
F 1083 Specification for Pipe, Steel, Hot-Dipped Zinc
6.1 The four types of chain-link fencing described in this
2
Coated (Galvanized) Welded for Fence Structures
practice are classified as follows:
F 1345 Specification for Zinc-5% Aluminum-Mischmetal
2 6.1.1 Type I—Built with aluminum-coated steel chain-link
Alloy-Coated Steel Chain-Link Fence Fabric
fence fabric as specified in Specification A 491.
F 1664 Specification for Poly(Vinyl Chloride) (PVC) and
6.1.2 Type II—Built with zinc-coated steel chain-link fence
fabric as specified in SpecificationA 392, Class 1 coating only.
6.1.3 Type III—Built with zinc-5% aluminum-mischmetal
1
This practice is under the jurisdiction ofASTM Committee F14 on Fences and
alloy-coated steel chain-link fence fabric as specified in Speci-
is the direct responsibility of Subcommittee F14.10 on Specific Applications.
fication F 1345, in a choice of Class 1 or Class 2 coating, as
Current edition approved Jan. 10, 2001. Published March 2001. Originally
selected.
published as F 969 – 86. Last previous edition F 969 – 96.
2
Annual Book of ASTM Standards, Vol 01.06.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
F969–01
6.1.4 Type IV—Built with polymer-coated steel chain-link 8.3.2 All fences shall have a top rail. Fences 12 ft (3660
fence fabric as specified in Specification F 668, in a choice of mm) in height shall have a continuous middle rail. Additional
Class 1, Class 2a, or Class 2b coating, as selected. rails at mid-points or at the bottom of the fence may be
specified.
7. Ordering Information
8.4 Bottom Tension Wire:
7.1 Purchase orders, construction specifications, or detailed
8.4.1 Bottom tension wire shall be used except where
drawings should include the following information:
continuous b
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.