SIGNIFICANCE AND USE
The intent of this guide is to provide information and guidelines for consideration by the designer or applicator of joint seals in, or adjacent to, EIFS. Refer to Specification E2568 for additional information pertaining to specifying Class PB EIFS. Refer to Guide E2511 for additional information pertaining to detailing of EIFS-Clad Wall Assemblies.
Proper selection and use of a sealant is fundamental to its ultimate performance, service life, and durability. A sealant joint subjected to movement and other similar performance factors should be designed for the particular application to avoid compromising its performance capability and causing failures. Refer to C1193 for guidance.
In addition to the design and installation data in this guide, consult the sealant manufacturer about applications for its products and their proper use and installation.
SCOPE
1.1 This guide describes the use of single and multi-component, cold-applied joint sealants, or precured sealant systems for joint sealing applications, or both, in buildings using Exterior Insulation and Finish Systems (EIFS) on one or both sides of the joint. Refer to 10.1 for joint seal geometries.
1.2 The elastomeric sealants described by this guide meet the requirements of Specifications C834, C920, or C1311.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.5 There are no ISO standards similar or equivalent to this ASTM standard.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1481 − 12
Standard Guide for
Use of Joint Sealants with Exterior Insulation and Finish
1
Systems (EIFS)
This standard is issued under the fixed designation C1481; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope C1382 Test Method for DeterminingTensileAdhesion Prop-
erties of Sealants When Used in Exterior Insulation and
1.1 This guide describes the use of single and multi-
Finish Systems (EIFS) Joints
component, cold-applied joint sealants, or precured sealant
C1397 Practice forApplication of Class PB Exterior Insula-
systems for joint sealing applications, or both, in buildings
tion and Finish Systems (EIFS) and EIFS with Drainage
using Exterior Insulation and Finish Systems (EIFS) on one or
C1472 Guide for Calculating Movement and Other Effects
both sides of the joint. Refer to 10.1 for joint seal geometries.
When Establishing Sealant Joint Width
1.2 The elastomeric sealants described by this guide meet
E2110 Terminology for Exterior Insulation and Finish Sys-
the requirements of Specifications C834, C920,or C1311.
tems (EIFS)
E2511 Guide for Detailing of EIFS-Clad Wall Assemblies
1.3 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this E2568 Specification for PB Exterior Insulation and Finish
Systems
standard.
2.2 ANSI Standard:
1.4 This standard does not purport to address all of the
American National Standard for Exterior Insulation and
safety concerns, if any, associated with its use. It is the
3
Finish Systems (EIFS)
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
3. Terminology
bility of regulatory limitations prior to use.
3.1 Definitions:
1.5 There are no ISO standards similar or equivalent to this
ASTM standard. 3.1.1 Refer to Terminology C717 for definitions of the
following terms used in this guide: bicellular sealant backing,
2. Referenced Documents bond breaker, bridge sealant joint, butt sealant joint, chemi-
2 cally curing sealant, closed cell sealant backing, compatibility,
2.1 ASTM Standards:
compatible materials, cure, elastomeric, elongation, fillet seal-
C717 Terminology of Building Seals and Sealants
ant joint, joint, lap sealant joint, latex sealant, modulus,
C719 Test Method for Adhesion and Cohesion of Elasto-
non-sag sealant, open cell sealant backing, precured sealant,
meric Joint Sealants Under Cyclic Movement (Hockman
primer, seal, sealant, sealant backing, shelf-life, solvent-
Cycle)
release sealant, shrinkage, substrate, tooling, tooling time,
C794 TestMethodforAdhesion-in-PeelofElastomericJoint
working life (pot life).
Sealants
3.1.2 Refer to Terminology E2110 for definitions of the
C834 Specification for Latex Sealants
following terms used in this guide: accessories, base coat,
C920 Specification for Elastomeric Joint Sealants
cure, dry, durability, edge wrap, embed, expansion joint,
C1193 Guide for Use of Joint Sealants
exterior insulation and finish system (EIFS), finish coat,
C1311 Specification for Solvent Release Sealants
lamina, nonmetallic reinforcing mesh, primers, reinforced base
coat, substrate, texture, thermal insulation board, wrap.
1
ThisguideisunderthejurisdictionofASTMCommitteeC24onBuildingSeals
4. Significance and Use
and Sealants and is the direct responsibility of Subcommittee C24.10 on
Specifications, Guides and Practices. 4.1 The intent of this guide is to provide information and
Current edition approved June 1, 2012. Published June 2012. Originally
guidelines for consideration by the designer or applicator of
approved in 2000. Last previous edition approved in 2011 as C1481-11. DOI:
joint seals in, or adjacent to, EIFS. Refer to Specification
10.1520/C1481-12.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
the ASTM website. 4th Floor, New York, NY 10036.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1481 − 12
E2568foradditionalinformationpertainingtospecifyingClass
PB EIFS. Refer to Guide E2511 for additional information
pertaining to detailing of EIFS-Clad Wall Assemblies.
4.2 Proper selection and use of a sealant is fundamental to
its ultimate performance, service life, and durability. A sealant
joint subjected to
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C1481–11 Designation:C1481–12
Standard Guide for
Use of Joint Sealants with Exterior Insulation and Finish
1
Systems (EIFS)
This standard is issued under the fixed designation C1481; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 Thisguidedescribestheuseofsingleandmulti-component,cold-appliedjointsealants,orprecuredsealantsystemsforjoint
sealing applications, or both, in buildings using Exterior Insulation and Finish Systems (EIFS) on one or both sides of the joint.
Refer to 10.1 for joint seal geometries.
1.2 The elastomeric sealants described by this guide meet the requirements of Specifications C834, C920, or C1311.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
1.5 There are no ISO standards similar or equivalent to this ASTM standard.
2. Referenced Documents
2
2.1 ASTM Standards:
C717 Terminology of Building Seals and Sealants
C719 Test Method for Adhesion and Cohesion of Elastomeric Joint Sealants Under Cyclic Movement (Hockman Cycle)
C794 Test Method for Adhesion-in-Peel of Elastomeric Joint Sealants
C834 Specification for Latex Sealants
C920 Specification for Elastomeric Joint Sealants
C1193 Guide for Use of Joint Sealants
C1311 Specification for Solvent Release Sealants
C1382 Test Method for Determining Tensile Adhesion Properties of Sealants When Used in Exterior Insulation and Finish
Systems (EIFS) Joints
C1397 Practice for Application of Class PB Exterior Insulation and Finish Systems (EIFS) and EIFS with Drainage
C1472 Guide for Calculating Movement and Other Effects When Establishing Sealant Joint Width
E2110 Terminology for Exterior Insulation and Finish Systems (EIFS)
E2511 Guide for Detailing of EIFS-Clad Wall Assemblies
E2568 Specification for PB Exterior Insulation and Finish Systems
2.2 ANSI Standard:
3
American National Standard for Exterior Insulation and Finish Systems (EIFS)
3. Terminology
3.1 Definitions:
3.1.1 Refer to Terminology C717 for definitions of the following terms used in this guide: bicellular sealant backing, bond
breaker, bridge sealant joint, butt sealant joint, chemically curing sealant, closed cell sealant backing, compatibility, compatible
materials, cure, elastomeric, elongation, fillet sealant joint, joint, lap sealant joint, latex sealant, modulus, non-sag sealant, open
cell sealant backing, precured sealant, primer, seal, sealant, sealant backing, shelf-life, solvent-release sealant, shrinkage,
substrate, tooling, tooling time, working life (pot life).
3.1.2 Refer to Terminology E2110 for definitions of the following terms used in this guide: accessories, base coat, cure, dry,
1
This guide is under the jurisdiction ofASTM Committee C24 on Building Seals and Sealants and is the direct responsibility of Subcommittee C24.10 on Specifications,
Guides and Practices.
Current edition approved JulyJune 1, 2011.2012. Published August 2011.June 2012. Originally approved in 2000. Last previous edition approved in 20062011 as
C1481-00(2006).C1481-11. DOI: 10.1520/C1481-112.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C1481–12
durability, edge wrap, embed, expansion joint, exterior insulation and finish system (EIFS), finish coat, lamina, nonmetallic
reinforcing mesh, primers, reinforced base coat, substrate, texture, thermal insulation board, wrap.
4. Significance and Use
4.1 The intent of this guide is to provide information and guidelines for consideration by the designer or applicator of joint seals
in, or adjacent to, EIFS. Refer to Specific
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.