Standard Specification for Mineral Fiber Roof Insulation Board

SCOPE
1.1 This specification covers the composition and physical properties of mineral fiber insulation board used principally above structural roof decks as a base for built-up roofing in building construction.
1.2 The use of thermal insulation materials covered by this specification may be regulated by building codes or other agencies that address fire performance, or both. The fire performance of the material should be addressed through standard fire test methods established by the appropriate governing documents.
1.3 The values stated in inch-pound units are to be regarded as the standard. the values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of the regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Nov-2000
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C726-00 - Standard Specification for Mineral Fiber Roof Insulation Board
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: C 726 – 00
Standard Specification for
1
Mineral Fiber Roof Insulation Board
This standard is issued under the fixed designation C 726; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
2
1. Scope Thermal Insulation Lots
C 518 Test Method for Steady-State Heat Flux Measure-
1.1 This specification covers the composition and physical
ments and Thermal Transmission Properties by Means of
properties of mineral fiber insulation board used principally
2
the Heat Flow Meter Apparatus
above structural roof decks as a base for built-up roofing in
C 976 Test Method for Thermal Performance of Building
building construction.
2
Assemblies by Means of a Calibrated Hot Box
1.2 The use of thermal insulation materials covered by this
3
D 312 Specification for Asphalt Used in Roofing
specification may be regulated by building codes or other
D 450 Specification for Coal-Tar Pitch Used in Roofing,
agencies that address fire performance, or both. The fire
3
Dampproofing, and Waterproofing
performance of the material should be addressed through
D 2126 Test Method for Response of Rigid Cellular Plastics
standard fire test methods established by the appropriate
4
to Thermal and Humid Aging
governing documents.
E 84 Test Method for Surface Burning Characteristics of
1.3 The values stated in inch-pound units are to be regarded
5
Building Materials
as the standard. the values given in parentheses are for
information only.
3. Terminology
1.4 This standard does not purport to address all of the
3.1 Definitions—Terms used in this specification are defined
safety concerns, if any, associated with its use. It is the
in Terminology C 168.
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
4. Ordering Information
bility of the regulatory limitations prior to use.
4.1 Orders for material purchased under this specification
shall include:
2. Referenced Documents
4.1.1 Designation of this specification,
2.1 The following standards, of the issue in effect on the
4.1.2 Product name,
date of material purchase, form a part of this specification to
4.1.3 Board dimensions,
the extent specified herein:
4.1.4 Quantity of material, and
2.2 ASTM Standards:
4.1.5 Special packaging or marking, (13.1 and 13.2) if
C 165 Test Method for Measuring Compressive Properties
2 required.
of Thermal Insulations
C 168 Terminology Relating to Thermal Insulating Materi-
5. Materials and Manufacture
2
als
5.1 Mineral fiber roof insulation board shall consist of
C 177 Test Method for Steady-State Heat Flux Measure-
mineral fibers with an organic resin or other suitable binder. It
ments and Thermal Transmission Properties by Means of
2 shall be faced during manufacture on one surface with a cover
the Guarded Hot Plate Apparatus
adequate for the application of Specification D 312 asphalt or
C 203 Test Methods for Breaking Load and Flexural Prop-
2 Specification D 450 coal-tar pitch built-up roofing.
erties of Block-Type Thermal Insulation
2
C 209 Test Methods for Cellulosic Fiber Insulating Board
6. Physical Properties
C 236 Test Method for Steady-State Thermal Performance
6.1 The average thermal resistance, R, of specimens
2
of Building Assemblies by Means of a Guarded Hot Box
sampled in accordance with Criteria C390 shall be as specified
C 390 Criteria for Sampling and Acceptance of Preformed
by the manufacturer.
6.2 Nominal thickness required to obtain the specified
1
This specification is under the jurisdiction of ASTM Committee C-16 on
Thermal Insulation, and is the direct responsibility of Subcommittee C16.20 on
Homogeneous Inorganic Thermal Insulations.
3
Current edition approved Jan. 10, 2000. Published April 2000. Originally Annual Book of ASTM Standards, Vol 04.04.
4
published as C 726 – 72. Last previous edition C 726 – 93. Annual Book of ASTM Standards, Vol 08.01.
2 5
Annual Book of ASTM Standards, Vol 04.06. Annual Book of ASTM Standards, Vol 04.07.
Copyright © ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C 726
resistance or conductance shall be as stated by the manufac- applied cover. Take care that the cover is not partially detached
turer. in the process of cutting specimens.
6.3 Roof insulation boards shall have the limiting property 10.2 Unless otherwise specified, condition samples prior to
values shown in Table 1. cutting specimens for at least 12 h at 73 6 2°F (24 6 1°C), 50
6 5 % relative humidity before testing.
...

Questions, Comments and Discussion