Standard Performance Specification for Flame Resistant and Electric Arc Rated Protective Clothing Worn by Workers Exposed to Flames and Electric Arcs

ABSTRACT
This performance specification covers the design characteristics and associated test methods that relate specifically to the flame resistance of textile materials used in the fabrication of basic protection level occupational apparel worn by electrical workers who are exposed to momentary electric arc and related thermal hazards such as exposure to open flame and radiant heat. When evaluated in accordance with the test procedures enlisted herein, knit fabrics and woven fabrics of different fabric weights shall conform to individually specified values of the following properties: colorfastness such as laundering shade change, dry-cleaning shade change, and dimensional change; initial flammability characteristics and flammability characteristics after 25 washes/dry-cleaning such as char length and afterflame time; and arc test rating. Knit fabrics shall additionally be tested and adhere accordingly to bursting strength characteristics. Conversely, woven fabrics shall also be tested and adhere accordingly to breaking load, tear resistance, and seam slippage characteristics.
SCOPE
1.1 This performance specification identifies minimum performance requirements to determine the (a) arc rating of fabrics, (b) flame resistance of fabrics and subassemblies, (c) mechanical durability of the fabrics and subassemblies, (d) the minimum garment construction and performance requirements, and (e) the garment labeling requirements for the completed protective clothing worn by workers exposed to flames and electric arcs.  
1.1.1 The minimum requirements for garment labeling are intended to provide end users with adequate information to select garments with the appropriate arc rating.  
1.1.2 End users are required to perform an assessment to determine the level of hazard and the required arc rating of the protective clothing for their individual hazards.
1.1.2.1 The end user risk assessments are outside the scope of this standard.  
1.2 This performance specification does not address coated or laminated protective clothing commonly used for rainwear applications in an arc hazard environment. Performance requirements related to this category of protective clothing are detailed in Specification F1891.  
1.3 This performance specification does not address hand protection. Performance and test requirements related to hand protection are detailed in OSHA 1910.138, Specification D120, and Test Method F2675/F2675M.  
1.4 The care and maintenance requirements for laundering electric arc flash protective clothing are outside the scope of this standard. Refer to Guides F1449 or F2757 related to industrial or home laundering.  
1.5 This standard should be used to evaluate and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions. It should not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions.  
1.5.1 The results of this evaluation may be used as elements of a fire-risk assessment that takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use.  
1.6 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.  
1.7 The following precautionary caveat pertains only to the test methods portion, Section 7, of this performance specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and...

General Information

Status
Historical
Publication Date
14-Nov-2017
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1506-17be1 - Standard Performance Specification for Flame Resistant and Electric Arc Rated Protective Clothing Worn by Workers Exposed to Flames and Electric Arcs
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F1506-17be1 - Standard Performance Specification for Flame Resistant and Electric Arc Rated Protective Clothing Worn by Workers Exposed to Flames and Electric Arcs
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation:F1506 −17b
Standard Performance Specification for
Flame Resistant and Electric Arc Rated Protective Clothing
1
Worn by Workers Exposed to Flames and Electric Arcs
This standard is issued under the fixed designation F1506; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—In Tables 2 and 3, the right hand column in the last row for Arc Rating was corrected from 7.7.1 to 7.7 in
January 2018.
1. Scope 1.5 This standard should be used to evaluate and describe
the properties of materials, products, or assemblies in response
1.1 This performance specification identifies minimum per-
to heat and flame under controlled laboratory conditions. It
formance requirements to determine the (a) arc rating of
should not be used to describe or appraise the fire hazard or
fabrics, (b) flame resistance of fabrics and subassemblies, (c)
fire risk of materials, products, or assemblies under actual fire
mechanical durability of the fabrics and subassemblies, (d) the
conditions.
minimumgarmentconstructionandperformancerequirements,
1.5.1 The results of this evaluation may be used as elements
and (e) the garment labeling requirements for the completed
of a fire-risk assessment that takes into account all of the
protective clothing worn by workers exposed to flames and
factors that are pertinent to an assessment of the fire hazard of
electric arcs.
a particular end use.
1.1.1 The minimum requirements for garment labeling are
intended to provide end users with adequate information to 1.6 The values stated in SI units are to be regarded as the
select garments with the appropriate arc rating. standard. The values given in parentheses are for information
1.1.2 End users are required to perform an assessment to only.
determine the level of hazard and the required arc rating of the
1.7 The following precautionary caveat pertains only to the
protective clothing for their individual hazards.
test methods portion, Section 7, of this performance specifica-
1.1.2.1 The end user risk assessments are outside the scope
tion: This standard does not purport to address all of the safety
of this standard.
concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety,
1.2 This performance specification does not address coated
health, and environmental practices and determine the appli-
or laminated protective clothing commonly used for rainwear
cability of regulatory limitations prior to use.
applications in an arc hazard environment. Performance re-
1.8 This international standard was developed in accor-
quirements related to this category of protective clothing are
dance with internationally recognized principles on standard-
detailed in Specification F1891.
ization established in the Decision on Principles for the
1.3 This performance specification does not address hand
Development of International Standards, Guides and Recom-
protection. Performance and test requirements related to hand
mendations issued by the World Trade Organization Technical
protectionaredetailedinOSHA1910.138,SpecificationD120,
Barriers to Trade (TBT) Committee.
and Test Method F2675/F2675M.
1.4 The care and maintenance requirements for laundering 2. Referenced Documents
2
electric arc flash protective clothing are outside the scope of
2.1 ASTM Standards:
this standard. Refer to Guides F1449 or F2757 related to
D120 Specification for Rubber Insulating Gloves
industrial or home laundering.
D123 Terminology Relating to Textiles
D1424 Test Method for Tearing Strength of Fabrics by
1
This performance specification is under the jurisdiction of ASTM Committee
F18 on Electrical Protective Equipment for Workers and is the direct responsibility
2
of Subcommittee F18.65 on Wearing Apparel. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Nov. 15, 2017. Published January 2018. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 1994. Last previous edition approved in 2017 as F1506–17a. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/F1506-17BE01. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
´1
F1506−17b
Falling-Pendulum (Elmendorf-Type) Apparatus 3.2.3 arc rating, n—value attributed to materials that de-
D2262 Test Method for Tearing Strength of Woven Fabrics scribes their performance to exposure to an electrical arc
by the Ton
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´1
Designation: F1506 − 17b F1506 − 17b
Standard Performance Specification for
Flame Resistant and Electric Arc Rated Protective Clothing
1
Worn by Workers Exposed to Flames and Electric Arcs
This standard is issued under the fixed designation F1506; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—In Tables 2 and 3, the right hand column in the last row for Arc Rating was corrected from 7.7.1 to 7.7 in
January 2018.
1. Scope
1.1 This performance specification identifies minimum performance requirements to determine the (a) arc rating of fabrics, (b)
flame resistance of fabrics and subassemblies, (c) mechanical durability of the fabrics and subassemblies, (d) the minimum garment
construction and performance requirements, and (e) the garment labeling requirements for the completed protective clothing worn
by workers exposed to flames and electric arcs.
1.1.1 The minimum requirements for garment labeling are intended to provide end users with adequate information to select
garments with the appropriate arc rating.
1.1.2 End users are required to perform an assessment to determine the level of hazard and the required arc rating of the
protective clothing for their individual hazards.
1.1.2.1 The end user risk assessments are outside the scope of this standard.
1.2 This performance specification does not address coated or laminated protective clothing commonly used for rainwear
applications in an arc hazard environment. Performance requirements related to this category of protective clothing are detailed
in Specification F1891.
1.3 This performance specification does not address hand protection. Performance and test requirements related to hand
protection are detailed in OSHA 1910.138, Specification D120, and Test Method F2675/F2675M.
1.4 The care and maintenance requirements for laundering electric arc flash protective clothing are outside the scope of this
standard. Refer to Guides F1449 or F2757 related to industrial or home laundering.
1.5 This standard should be used to evaluate and describe the properties of materials, products, or assemblies in response to
heat and flame under controlled laboratory conditions. It should not be used to describe or appraise the fire hazard or fire risk
of materials, products, or assemblies under actual fire conditions.
1.5.1 The results of this evaluation may be used as elements of a fire-risk assessment that takes into account all of the factors
that are pertinent to an assessment of the fire hazard of a particular end use.
1.6 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.7 The following precautionary caveat pertains only to the test methods portion, Section 7, of this performance specification:
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the
user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D120 Specification for Rubber Insulating Gloves
1
This performance specification is under the jurisdiction of ASTM Committee F18 on Electrical Protective Equipment for Workers and is the direct responsibility of
Subcommittee F18.65 on Wearing Apparel.
Current edition approved Nov. 15, 2017. Published January 2018. Originally approved in 1994. Last previous edition approved in 2017 as F1506–17a. DOI:
10.1520/F1506-17B.10.1520/F1506-17BE01.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
´1
F1506 − 17b
D123 Ter
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.