Standard Specification for Lime Putty for Structural Purposes

ABSTRACT
This specification covers lime putty products made from hydrated lime or quicklime products. Lime putty is suitable for use in masonry, plaster and stucco applications. The hydrated lime or quicklime products used to make lime putty shall be tested and shall conform to the chemical composition, plasticity, residue, soaking period, popping and pitting, and density requirements specified.
SCOPE
1.1 This specification covers lime putty products made from hydrated lime or quicklime products. Lime putty is suitable for use in masonry, plaster and stucco applications.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-May-2008
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1489-01(2008)e1 - Standard Specification for Lime Putty for Structural Purposes
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation:C1489 −01(Reapproved 2008)
Standard Specification for
Lime Putty for Structural Purposes
This standard is issued under the fixed designation C1489; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
´ NOTE—A units statement was added editorially as new subsection 1.2 in September 2008.
1. Scope 3.1.1 lime putty—the product obtained by either slaking
quicklime with water according to the direction of the manu-
1.1 This specification covers lime putty products made from
facturer or by mixing hydrated lime and water to the desired
hydrated lime or quicklime products. Lime putty is suitable for
consistency.
use in masonry, plaster and stucco applications.
3.1.2 Unless otherwise specified, for definitions of terms
1.2 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this used in this standard, refer to Terminology C51.
standard.
4. Chemical Composition
1.3 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
4.1 The hydrated lime or quicklime products used to make
responsibility of the user of this standard to establish appro-
lime putty shall conform to the following chemical composi-
priate safety and health practices and determine the applica-
tion requirements:
bility of regulatory limitations prior to use.
Calcium and magnesium oxides (non volatile basis) 92 % min.
Carbon dioxide (presoaked basis)
2. Referenced Documents
If sample is taken at place of manufacture 5 % max.
If sample is taken at other place 7 % max.
2.1 ASTM Standards:
C5 Specification for Quicklime for Structural Purposes
4.2 Chemical composition of putty product of unknown
C25 Test Methods for Chemical Analysis of Limestone,
compositionmustbedeterminedbydryingthesampleinaCO
Quicklime, and Hydrated Lime
free atmosphere by a method such as Test Methods C25,
C50 Practice for Sampling, Sample Preparation, Packaging,
Section 21, (Free Moisture in Hydrated Lime).
and Marking of Lime and Limestone Products
C51 Terminology Relating to Lime and Limestone (as used
5. Plasticity
by the Industry)
5.1 Lime putty shall have a plasticity of not less than 200
C110 Test Methods for Physical Testing of Quicklime,
Emley units when tested by the Emley method prescribed in
Hydrated Lime, and Limestone
Test Methods C110. Vicat consistency of the putty should be
C185 Test Method for Air Content of Hydraulic Cement
adjusted to a penetration of 20 6 5 mm prior to running the
Mortar
Emley test. If penetration results are above 25 mm, the
C206 Specification for Finishing Hydrated Lime
consistency of the putty can be increased by allowing the putty
C207 Specification for Hydrated Lime for Masonry Pur-
to settle and decanting off the excess water or by the use of a
poses
suction pad such as the one used for the water retention test in
3. Terminology
Test Methods C110. If the penetration is below 15 mm, water
should be added to the lime putty to increase the penetration.
3.1 Definitions:
Whenwaterisaddedtotheputty,theputtyshouldbemixedfor
a minimum of 15 s prior to testing the penetration.
This specification is under the jurisdiction of ASTM Committee C07 on Lime
and is the direct responsibility of Subcommittee C07.02 on Specifications and
6. Residue
Guidelines.
Current edition approved June 1, 2008. Published September 2008. Originally
6.1 Residue of lime putty shall not be more than 0.5 % on a
approved in 2001. Last previous edition approved in 2001 as C1489 – 01. DOI:
10.1520/C1489-01R08E01.
30meshsieveonatotalputtyweightbasis.Theresidueoflime
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
putty should be determined by the method in Test Methods
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
C110, Section 5, using an amount of lime putty equivalen
...

Questions, Comments and Discussion