Standard Specification for Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe (Metric)

SCOPE
1.1 This specification covers reinforced elliptically shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts.
1.2 Pipe designed for placement with the major axis horizontal shall be designated as "Horizontal Elliptical Pipe." Pipe designed for placement with the major axis vertical shall be designated as "Vertical Elliptical Pipe."
1.3 This specification is the metric counterpart of Specification C 507.
Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.

General Information

Status
Historical
Publication Date
30-Sep-2005
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C507M-05b - Standard Specification for Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe (Metric)
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 507M – 05b
METRIC
Standard Specification for
Reinforced Concrete Elliptical Culvert, Storm Drain, and
1
Sewer Pipe [Metric]
This standard is issued under the fixed designation C 507M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope A 496/A 496M Specification for Steel Wire, Deformed, for
Concrete Reinforcement
1.1 This specification covers reinforced elliptically shaped
A 497/A 497M Specification for Steel Welded Wire Rein-
concrete pipe to be used for the conveyance of sewage,
forcement, Deformed, for Concrete
industrial wastes, storm water, and for the construction of
A 615/A 615M Specification for Deformed and Plain
culverts.
Billet-Steel Bars for Concrete Reinforcement [Metric]
1.2 Pipe designed for placement with the major axis hori-
C33 Specification for Concrete Aggregates
zontal shall be designated as “Horizontal Elliptical Pipe.” Pipe
C 150 Specification for Portland Cement
designed for placement with the major axis vertical shall be
C 260 Specification forAir-EntrainingAdmixtures for Con-
designated as “Vertical Elliptical Pipe.”
crete
1.3 This specification is the metric counterpart of Specifi-
C 309 Specification for Liquid Membrane-Forming Com-
cation C 507.
pounds for Curing Concrete
NOTE 1—This specification is a manufacturing and purchase specifica-
C 494/C 494M Specification for Chemical Admixtures for
tion only, and does not include requirements for bedding, backfill, or the
Concrete
relationship between field load condition and the strength classification of
C 497M Test Methods for Concrete Pipe, Manhole Sec-
pipe. However, experience has shown that the successful performance of
tions, or Tile [Metric]
this product depends upon the proper selection of the class of pipe, type
C 595 Specification for Blended Hydraulic Cements
of bedding and backfill, and care that the installation conforms to
construction specifications. The owner of the reinforced concrete pipe
C 618 Specification for Coal Fly Ash and Raw or Calcined
specified herein is cautioned that he must correlate the field requirements
Natural Pozzolan for Use in Concrete
with the class of pipe specified and provide inspection at the construction
C 822 Terminology Relating to Concrete Pipe and Related
site.
Products
C 989 Specification for Ground Granulated Blast-Furnace
2. Referenced Documents
Slag for Use in Concrete and Mortars
2
2.1 ASTM Standards:
C 1017/C 1017M Specification for Chemical Admixtures
A 82/A 82M Specification for Steel Wire, Plain, for Con-
for use in Producing Flowing Concrete
crete Reinforcement
C 1116 Specification for Fiber-Reinforced Concrete and
A 185 Specification for Steel Welded Wire Reinforcement,
Shotcrete
Plain, for Concrete
3. Terminology
3.1 Definitions—For definitions of terms relating to con-
1
This specification is under the jurisdiction of ASTM Committee C13 on crete pipe, see Terminology C 822.
Concrete Pipe and is the direct responsibility of Subcommittee C13.02 on
Reinforced Sewer and Culvert Pipe.
4. Classification
Current edition approved Oct. 1, 2005. Published November 2005. Originally
4.1 Pipe manufactured according to this specification shall
approved in 1980. Last previous edition approved in 2005 as C 507M–05a.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or be of five classes each for horizontal elliptical and vertical
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
elliptical pipe with identification as follows:
Standards volume information, refer to the standard’s Document Summary page on
Horizontal Elliptical Pipe Vertical Elliptical Pipe
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C 507M – 05b
shall be determined by the results of the three-edge-bearing
Class HE-A Class VE-II
Class HE-I Class VE-III
tests as defined in 11.3.1; by such material tests as are required
Class HE-II Class VE-IV
in 6.1, 6.2, and 6.4; by an absorption test of the concrete from
Class HE-III Class VE-V
Class HE-IV Class VE-VI the wall of the pipe for each mix design that is used on an
order; and by visual inspection of the finished pipe to deter-
4.2 The strength requirements for horizontal elliptical pipe
mine its conformance with the accepted design prescribed and
are prescribed in Table 1 and for vertical elliptical pipe are
its freedom from defects.
prescribed in Table 2.
5.1.2 Acceptance on the Basis of Material Test and Inspe
...