Standard Specification for Mineral Fiber Loose-Fill Thermal Insulation

SCOPE
1.1 This specification covers the composition and physical properties of nodulated mineral fiber thermal insulation for use in attics or enclosed spaces in housing and other framed buildings.  
1.2 The values stated in inch-pound units are to be regarded as the standard. The values in parentheses are provided for information only.  
1.3 When the installation and use of thermal insulation materials may expose individuals to health and safety hazards, the manufacturer shall provide the user with appropriate information regarding any known hazards associated with the designated use of its product, and shall recommend the protective measures to be employed in its safe utilization. The user shall establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
1.4 The following precautionary caveat pertains only to the test method portion, Section 12, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Dec-1999
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C764-99 - Standard Specification for Mineral Fiber Loose-Fill Thermal Insulation
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: C 764 – 99
Standard Specification for
1
Mineral Fiber Loose-Fill Thermal Insulation
This standard is issued under the fixed designation C 764; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope C 1304 Test Method for Assessing The Odor Emission of
3
Thermal Insulation Materials
1.1 This specification covers the composition and physical
C 1338 Test Method for Determining Fungi Resistance of
properties of nodulated mineral fiber thermal insulation for use
3
Insulation Materials and Facings
in attics or enclosed spaces in housing and other framed
E 136 Test Method for Behavior of Materials in a Vertical
buildings.
4
Tube Furnace at 750°C
1.2 The values stated in inch-pound units are to be regarded
E 970 Test Method for Critical Radiant Flux of Exposed
as the standard. The values in parentheses are provided for
Attic Floor Insulation Using a Radiant Energy Heat
information only.
4
Source
1.3 This standard does not purport to address all of the
G 1 Practice for Preparing, Cleaning, and Evaluating Cor-
safety concerns, if any, associated with its use. It is the
5
rosion Test Specimens
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
3. Terminology
bility of regulatory limitations prior to use.
3.1 Definitions—For definitions of terms used in this speci-
2. Referenced Documents fication, refer to Terminology C 168.
2.1 ASTM Standards:
4. Classification
B 152 Specification for Copper, Sheet, Strip, Plate, and
2 4.1 The nodulated mineral fiber thermal insulation shall be
Rolled Bar
of the following types and classes:
C 168 Terminology Relating to Thermal Insulating Materi-
3 4.1.1 Type I—Pneumatic application.
als
4.1.2 Type II—Poured application.
C 177 Test Method for Steady-State Heat Flux Measure-
ments and Thermal Transmission Properties by Means of
5. Ordering Information
3
the Guarded Hot Plate Apparatus
5.1 Both types of nodulated mineral fiber thermal insulation
C 236 Test Method for Steady-State Thermal Performance
3 are intended for use as thermal insulation in open spaces, such
of Building Assemblies by Means of a Guarded Hot Box
as attics and enclosed spaces, such as walls, in housing and
C 390 Criteria for Sampling and Acceptance of Preformed
3 buildings at ambient temperatures. Type I is used for pneumatic
Thermal Insulation Lots
application (blown or conveyed by an air stream through a hose
C 518 Test Method for Steady-State Heat Flux Measure-
and discharged over the area to be insulated).Type II is used for
ments and Thermal Transmission Properties by Means of
application by pouring in place.
3
the Heat Flow Meter Apparatus
C 519 Test Method for Density of Fibrous Loose-Fill Build-
6. Materials and Manufacture
3
ing Insulations
6.1 Basic Material— The basic material shall be fibers
C 687 Practice for Determination of Thermal Resistance of
made from mineral substances such as rock, slag, or glass
3
Loose-Fill Type Building Insulation
processed from the molten state into an incombustible fibrous
C 1104/C1104M Test Method for Determining the Water
form.
3
Vapor Sorption of Unfaced Mineral Fiber Insulation
6.2 Manufacture— The fibers shall be mechanically pro-
cessed into nodules, and may be treated to provide improved
1
This specification is under the jurisdiction of ASTM Committee C-16 on
processing and handling characteristics suitable for installation
Thermal Insulation and is the direct responsibility of Subcommittee C16.23 on
Blanket and Loose Fill Insulation. by pouring or pneumatic applications.
Current edition approved December 10, 1999. Published March 2000. Originally
published as C 764 – 73. Last previous edition C 764 – 98.
2
4
Annual Book of ASTM Standards, Vol 02.01.
Annual Book of ASTM Standards, Vol 04.07.
3
5
Annual Book of ASTM Standards, Vol 04.06.
Annual Book of ASTM Standards, Vol 03.02.
Copyright © ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
C 764
7. Physical Properties foreign materials and shall be clean and dry. The insulation
shall not have visible defects that will adversely affect the
7.1 Thermal Characteristics—The standard thermal resis-
service quality.
tance values normally recommended for open application are:
11, 19, 22, 30, and 38 (1.9, 2
...