Standard Performance Specification for Flame Resistant and Arc Rated Textile Materials for Wearing Apparel for Use by Electrical Workers Exposed to Momentary Electric Arc and Related Thermal Hazards

ABSTRACT
This performance specification covers the design characteristics and associated test methods that relate specifically to the flame resistance of textile materials used in the fabrication of basic protection level occupational apparel worn by electrical workers who are exposed to momentary electric arc and related thermal hazards such as exposure to open flame and radiant heat. When evaluated in accordance with the test procedures enlisted herein, knit fabrics and woven fabrics of different fabric weights shall conform to individually specified values of the following properties: colorfastness such as laundering shade change, dry-cleaning shade change, and dimensional change; initial flammability characteristics and flammability characteristics after 25 washes/dry-cleaning such as char length and afterflame time; and arc test rating. Knit fabrics shall additionally be tested and adhere accordingly to bursting strength characteristics. Conversely, woven fabrics shall also be tested and adhere accordingly to breaking load, tear resistance, and seam slippage characteristics.
SCOPE
1.1 This performance specification identifies minimum flame resistance, construction, durability, and labeling requirements of textiles and subassemblies used in the manufacture of protective clothing worn by electrical workers to protect against exposure to momentary electric arc flash and related thermal hazards.  
1.1.1 This performance specification does not address coated or laminated fabrics commonly used for rainwear applications in an arc hazard environment.  
1.2 This performance specification defines minimum garment manufacturing and labeling requirements to allow users to select garments with appropriate electric arc ratings for protection from their determined electric arc flash hazard environment.  
1.2.1 A prior determination of the electric arc flash hazard environment is required in order to select appropriate protective garments. This prior determination is outside the scope of this specification.  
1.2.2 The care and maintenance requirements for electric arc flash protective garments are outside the scope of this standard.  
1.3 This standard should be used to evaluate and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions. It should not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions.  
1.3.1 The results of this evaluation may be used as elements of a fire-risk assessment that takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use.  
1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.  
1.5 The following precautionary caveat pertains only to the test methods portion, Section 7, of this performance specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Oct-2015
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1506-15 - Standard Performance Specification for Flame Resistant and Arc Rated Textile Materials for Wearing Apparel for Use by Electrical Workers Exposed to Momentary Electric Arc and Related Thermal Hazards
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F1506-15 - Standard Performance Specification for Flame Resistant and Arc Rated Textile Materials for Wearing Apparel for Use by Electrical Workers Exposed to Momentary Electric Arc and Related Thermal Hazards
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F1506 −15
Standard Performance Specification for
Flame Resistant and Arc Rated Textile Materials for Wearing
Apparel for Use by Electrical Workers Exposed to
1
Momentary Electric Arc and Related Thermal Hazards
This standard is issued under the fixed designation F1506; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.4 The values stated in SI units are to be regarded as the
standard. The values given in parentheses are for information
1.1 This performance specification identifies minimum
only.
flame resistance, construction, durability, and labeling require-
1.5 The following precautionary caveat pertains only to the
ments of textiles and subassemblies used in the manufacture of
test methods portion, Section 7, of this performance specifica-
protective clothing worn by electrical workers to protect
tion: This standard does not purport to address all of the safety
against exposure to momentary electric arc flash and related
concerns, if any, associated with its use. It is the responsibility
thermal hazards.
of the user of this standard to establish appropriate safety and
1.1.1 This performance specification does not address
health practices and determine the applicability of regulatory
coated or laminated fabrics commonly used for rainwear
limitations prior to use.
applications in an arc hazard environment.
1.2 This performance specification defines minimum gar- 2. Referenced Documents
ment manufacturing and labeling requirements to allow users 2
2.1 ASTM Standards:
to select garments with appropriate electric arc ratings for
D123 Terminology Relating to Textiles
protection from their determined electric arc flash hazard
D434 Test Method for Resistance to Slippage of Yarns in
environment.
Woven Fabrics Using a Standard Seam (Withdrawn
3
1.2.1 A prior determination of the electric arc flash hazard
2003)
environment is required in order to select appropriate protec-
D1424 Test Method for Tearing Strength of Fabrics by
tive garments. This prior determination is outside the scope of
Falling-Pendulum (Elmendorf-Type) Apparatus
this specification.
D2262 Test Method for Tearing Strength of Woven Fabrics
1.2.2 The care and maintenance requirements for electric by the Tongue (Single Rip) Method (Constant-Rate-of-
3
arc flash protective garments are outside the scope of this Traverse Tensile Testing Machine) (Withdrawn 1995)
standard. D2724 Test Methods for Bonded, Fused, and Laminated
Apparel Fabrics
1.3 This standard should be used to evaluate and describe
D3786 Test Method for Bursting Strength of Textile
the properties of materials, products, or assemblies in response
Fabrics—Diaphragm Bursting Strength Tester Method
to heat and flame under controlled laboratory conditions. It
D5034 TestMethodforBreakingStrengthandElongationof
should not be used to describe or appraise the fire hazard or
Textile Fabrics (Grab Test)
fire risk of materials, products, or assemblies under actual fire
D6413 Test Method for Flame Resistance of Textiles (Ver-
conditions.
tical Test)
1.3.1 The results of this evaluation may be used as elements
F1449 Guide for Industrial Laundering of Flame, Thermal,
of a fire-risk assessment that takes into account all of the
and Arc Resistant Clothing
factors that are pertinent to an assessment of the fire hazard of
F1959/F1959M TestMethodforDeterminingtheArcRating
a particular end use.
of Materials for Clothing
1 2
This performance specification is under the jurisdiction of ASTM Committee For referenced ASTM standards, visit the ASTM website, www.astm.org, or
F18 on Electrical Protective Equipment for Workers and is the direct responsibility contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
of Subcommittee F18.65 on Wearing Apparel. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Nov. 1, 2015. Published November 2015. Originally the ASTM website.
3
approved in 1994. Last previous edition approved in 2010 as F1506–10a. DOI: The last approved version of this historical standard is referenced on
10.1520/F1506-15. www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1506−15
4
2.2 AATCC Test Methods: 3.2.7 breakopen threshold energy (E ), n—the incident
BT
Method 61 Colorfastness to Washing, Domestic and energy on a material or material system that results in a 50 %
Laundering, Commercial: Accelerated probability of breakopen.
2 2
Method 132 Colorfastness to Dry-Cleaning 3.2.7.1 Dis
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F1506 − 10a F1506 − 15
Standard Performance Specification for
Flame Resistant and Arc Rated Textile Materials for Wearing
Apparel for Use by Electrical Workers Exposed to
1
Momentary Electric Arc and Related Thermal Hazards
This standard is issued under the fixed designation F1506; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This performance specification covers the flame resistance of textile materials to be used for wearing apparel for use
identifies minimum flame resistance, construction, durability, and labeling requirements of textiles and subassemblies used in the
manufacture of protective clothing worn by electrical workers exposed to to protect against exposure to momentary electric arc
flash and related thermal hazards.
NOTE 1—This performance specification does not cover coated fabrics commonly used in rainwear.
1.1.1 This performance specification does not address coated or laminated fabrics commonly used for rainwear applications in
an arc hazard environment.
NOTE 2—At present, a bench scale arc test for laboratory use is not available. It is the intent of the committee to continue the search for an acceptable
laboratory test based on either an electric arc exposure or an acceptable alternative, which will form the basis of a modification of this performance
specification.
1.2 Materials used for basic protection levels are covered.
1.3 Protective properties relate to thermal exposure from momentary arc and associated exposure to open flame and radiant heat.
(See Appendix X1.)
1.2 This performance specification covers wearing apparel design characteristics that relate specifically to protection from
exposure to momentary electric arc and that relate to the utility of the wearing apparel.defines minimum garment manufacturing
and labeling requirements to allow users to select garments with appropriate electric arc ratings for protection from their
determined electric arc flash hazard
NOTE 3—A number of other thermal test methods are under consideration and development and, when evaluated and proved effective by Committee
F18, will be incorporated in either this performance specification or an appropriate alternative test method or specification.environment.
1.2.1 A prior determination of the electric arc flash hazard environment is required in order to select appropriate protective
garments. This prior determination is outside the scope of this specification.
1.2.2 The care and maintenance requirements for electric arc flash protective garments are outside the scope of this standard.
1.3 This standard should be used to evaluate and describe the properties of materials, products, or assemblies in response to
heat and flame under controlled laboratory conditions. It should not be used to describe or appraise the fire hazard or fire risk
of materials, products, or assemblies under actual fire conditions.
1.3.1 The results of this evaluation may be used as elements of a fire-risk assessment that takes into account all of the factors
that are pertinent to an assessment of the fire hazard of a particular end use.
1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.5 The following precautionary caveat pertains only to the test methods portion, Section 7, of this performance specification-
:This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the
user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations
prior to use.
1
This performance specification is under the jurisdiction of ASTM Committee F18 on Electrical Protective Equipment for Workers and is the direct responsibility of
Subcommittee F18.65 on Wearing Apparel.
Current edition approved Oct. 1, 2010Nov. 1, 2015. Published October 2010November 2015. Originally approved in 1994. Last previous edition approved in 2010 as
F1506–10.–10a. DOI: 10.1520/F1506-10A.10.1520/F1506-15.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1506 − 15
2. Referenced Documents
2
2.1 ASTM Standards:
D123 Terminology Relating to Textiles
3
...

Questions, Comments and Discussion