ASTM C1281-03(2009)
(Specification)Standard Specification for Preformed Tape Sealants for Glazing Applications
Standard Specification for Preformed Tape Sealants for Glazing Applications
ABSTRACT
This specification describes preformed tape sealants for use in glazing applications. These materials are generally used to serve as components of glazing systems. They are intended to serve as a water and air barrier. The preformed tape sealant shall be composed of appropriate raw materials conformed to the requirements specified. The preformed tape sealant shall be of uniform dimensions and consistency. When properly applied, this material shall form a seal to prevent air and water from entering the system. Different test methods shall be performed in order to determine the following properties: low temperature flexibility, weight loss, vehicle migration, backing removal, yield strength, compression or recovery, water absorption, and flow.
SIGNIFICANCE AND USE
This specification describes only preformed tape sealants for glazing applications. Their use is specific under glazing systems to serve as a water and air barrier. The test methods chosen are to determine their efficiency in this use. This specification does not describe all required properties of the preformed tape sealants. It should be recognized by the purchaser and design professional that not all preformed tape sealants meeting this specification are suitable for all applications. In some instances, additional requirements will be agreed to by the supplier and user.
SCOPE
1.1 This specification describes preformed tape sealants for use in glazing applications. These materials are generally used to serve as components of glazing systems. They are intended to serve as a water and air barrier.
1.2 This specification is not intended for preformed foam tape sealants.
1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are provided for information purposes only.
1.4 The subcommittee with jurisdiction is not aware of any similar ISO standard.
1.5 The following precautionary statement pertains only to the test method section of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1281 −03(Reapproved 2009)
Standard Specification for
Preformed Tape Sealants for Glazing Applications
This standard is issued under the fixed designation C1281; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope C972 Test Method for Compression-Recovery of Tape Seal-
ant
1.1 This specification describes preformed tape sealants for
C1016 Test Method for Determination of Water Absorption
use in glazing applications. These materials are generally used
of Sealant Backing (Joint Filler) Material
to serve as components of glazing systems. They are intended
C1266 Test Method for Flow Characteristics of Preformed
to serve as a water and air barrier.
Tape Sealants
1.2 This specification is not intended for preformed foam
tape sealants.
3. Terminology
1.3 The values stated in SI units are to be regarded as the
3.1 Definitions—Thedefinitionsofthefollowingtermsused
standard. The values in parentheses are provided for informa-
in this specification are found in Terminology C717: compres-
tion purposes only.
sion seal, glazing, tape sealant.
1.4 The subcommittee with jurisdiction is not aware of any
similar ISO standard.
4. Materials and Manufacturers
1.5 The following precautionary statement pertains only to
4.1 The preformed tape sealant shall be composed of
the test method section of this specification. This standard does
appropriate raw materials to result in conformance to this
not purport to address all of the safety concerns, if any,
specification.
associated with its use. It is the responsibility of the user of this
4.2 The preformed tape sealant shall be of uniform dimen-
standard to establish appropriate safety and health practices
sions and consistency.
and determine the applicability of regulatory limitations prior
to use.
4.3 When properly applied, this material shall form a seal to
prevent air and water from entering the system.
2. Referenced Documents
2.1 ASTM Standards:
5. Requirements
C717 Terminology of Building Seals and Sealants
5.1 The tape sealant in the original unopened container shall
C765 Test Method for Low-Temperature Flexibility of Pre-
meet the requirements of this specification and remain suitable
formed Tape Sealants
for use for a minimum of 12 months from the date of
C771 Test Method for Weight Loss After Heat Aging of
manufacture when stored at a temperature of 26.6°C (80°F)
Preformed Tape Sealants
maximum.
C772 Test Method for Oil Migration or Plasticizer Bleed-
Out of Preformed Tape Sealants
5.2 Physical Properties—The physical properties of the
C879 Test Methods for Release Papers Used with Preformed
material shall conform to the requirements specified in Table 1.
Tape Sealants
C908 Test Method for Yield Strength of Preformed Tape
6. Significance and Use
Sealants
6.1 This specification describes only preformed tape seal-
ants for glazing applications. Their use is specific under
This specification is under the jurisdiction of ASTM Committee C24 on
glazing systems to serve as a water and air barrier. The test
Building Seals and Sealants and is the direct responsibility of Subcommittee C24.10
methods chosen are to determine their efficiency in this use.
on Specifications, Guides and Practices.
This specification does not describe all required properties of
Current edition approved Jan. 1, 2009. Published March 2009. Originally
the preformed tape sealants. It should be recognized by the
approved in 1994. Last previous edition approved in 2003 as C1281 – 03. DOI:
10.1520/C1281-03R09.
purchaser and design professional that not all preformed tape
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
sealants meeting this specification are suitable for all applica-
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
tions.Insomeinstances,additionalrequirementswillbeagreed
Standards volume information, refer to the standard’
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C1281–99 Designation: C 1281 – 03 (Reapproved 2009)
Standard Specification for
Preformed Tape Sealants for Glazing Applications
This standard is issued under the fixed designation C 1281; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification describes preformed tape sealants for use in glazing applications. These materials are generally used to
serve as components of glazing systems. They are intended to serve as a water and air barrier.
1.2 This specification is not intended for preformed foam tape sealants.
1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are provided for information
purposes only.
1.4
1.4 The subcommittee with jurisdiction is not aware of any similar ISO standard.
1.5 The following precautionary statement pertains only to the test method section of this specification. This standard does not
purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to
establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:
C 717 Terminology of Building Seals and Sealants
C 765 Test Method for Low-Temperature Flexibility of Preformed Tape Sealants
C 771 Test Method for Weight Loss After Heat Aging of Preformed Tape Sealants
C 772 Test Method for Oil Migration or Plasticizer Bleed-Out of Preformed Tape Sealants
C 879 Test Methods for Release Papers Used with Preformed Tape Sealants
C 908 Test Method for Yield Strength of Preformed Tape Sealants
C 972 Test Method for Compression-Recovery of Preformed Tape Sealants Sealant
C 1016 Test Method for Determination of Water Absorption of Sealant Backing (Joint Filler) Material
C 1266 Test Method for Flow Characteristics of Preformed Tape Sealants
3. Terminology
3.1 Definitions—The definitions of the following terms used in this specification are found in Terminology C 717: compression
seal, glazing, tape sealant.
4. Materials and Manufacturers
4.1 The preformed tape sealant shall be composed of appropriate raw materials to result in conformance to this specification.
4.2 The preformed tape sealant shall be of uniform dimensions and consistency.
4.3 When properly applied, this material shall form a seal to prevent air and water from entering the system.
5. Requirements
5.1 The tape sealant in the original unopened container shall meet the requirements of this specification and remain suitable for
use for a minimum of 12 months from the date of manufacture when stored at a temperature of 26.6°C (80°F) maximum.
5.2 Physical Properties—The physical properties of the material shall conform to the requirements specified in Table 1.
This specification is under the jurisdiction ofASTM Committee C24 on Building Seals and Sealants and is the direct responsibility of Subcommittee C24.20 on General
Sealant Standards.
Current edition approved Jan. 10, 1999. Published April 1999. Originally published as C 1281–94. Last previous edition C 1281–94.
This specification is under the jurisdiction of ASTM Committee C24 on Building Seals and Sealants and is the direct responsibility of Subcommittee C24.10 on
Specifications, Guides and Practices.
Current edition approved Jan. 1, 2009. Published March 2009. Originally approved in 1994. Last previous edition approved in 2003 as C 1281 – 03.
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
, Vol 04.07.volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
C 1281 – 03 (2009)
TABLE 1 Material Requi
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.