SIGNIFICANCE AND USE
4.1 The toluene discoloration value provides an estimate of toluene-soluble discoloring residues present on the carbon black.
SCOPE
1.1 This test method covers the measurement of the degree of toluene discoloration by carbon black extractables and is useful in controlling the reaction processes for production of carbon black. This test method may not be applicable to carbon blacks with high extractables.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Relations
Buy Standard
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D1618 − 23
Standard Test Method for
Carbon Black Extractables—Transmittance of Toluene
1
Extract
This standard is issued under the fixed designation D1618; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 3.1.1 carbon black toluene discoloration, n— the
transmittance, at 425 nm, of the filtrate obtained from the
1.1 This test method covers the measurement of the degree
toluene extract of carbon black, compared to that of pure
of toluene discoloration by carbon black extractables and is
toluene.
useful in controlling the reaction processes for production of
carbon black. This test method may not be applicable to carbon
4. Significance and Use
blacks with high extractables.
4.1 The toluene discoloration value provides an estimate of
1.2 The values stated in SI units are to be regarded as
toluene-soluble discoloring residues present on the carbon
standard. No other units of measurement are included in this
black.
standard.
1.3 This standard does not purport to address all of the
5. Apparatus and Reagent
safety concerns, if any, associated with its use. It is the
5.1 Spectrophotometer, with tungsten filament lamp, 20-nm
responsibility of the user of this standard to establish appro-
maximum spectral bandpass, capable of measuring percent
priate safety, health, and environmental practices and deter-
transmittance at a 425-nm wavelength. The instrument is to be
mine the applicability of regulatory limitations prior to use.
operated in accordance with the manufacturer’s directions for
1.4 This international standard was developed in accor-
optimum performance.
dance with internationally recognized principles on standard-
5.2 Cuvets, rectangular, with an optical light path of 10 mm.
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
5.3 Balance, analytical, with a sensitivity of 60.01 g.
mendations issued by the World Trade Organization Technical
5.4 Oven, gravity-convection type, capable temperature
Barriers to Trade (TBT) Committee.
regulation within 61°C at 125°C and temperature uniformity
2. Referenced Documents within 65°C.
2 3
2.1 ASTM Standards: 5.5 Pipet, automatic, bottle-type, 20 cm , with a repeatabil-
D1799 Practice for Carbon Black—Sampling Packaged ity of 60.1.
Shipments 3
5.6 Erlenmeyer Flasks, 125 cm with ground-glass stopper.
D1900 Practice for Carbon Black—Sampling Bulk Ship-
5.7 Filter Paper, qualitative grade, 150-mm diameter, pore
ments
size of 2 to 3 μm.
D4483 Practice for Evaluating Precision for Test Method
Standards in the Rubber and Carbon Black Manufacturing
5.8 Glass Filtering Funnels, 75-mm inside diameter at the
Industries
top.
3
5.9 Beakers, 50 or 100 cm , with pouring lips.
3. Terminology
5.10 Wiping Paper, lint-free.
3.1 Definitions:
5.11 Cotton Swabs.
1
This test method is under the jurisdiction of ASTM Committee D24 on Carbon
5.12 Fume Hood, fully enclosed on three sides, with spark-
Black and is the direct responsibility of Subcommittee D24.31 on Non-Carbon
proof fan and motor.
Black Components of Carbon Black.
Current edition approved Nov. 1, 2023. Published November 2023. Originally
5.13 Toluene, analytical reagent grade.
approved in 1965. Last previous edition approved in 2018 as D1618 – 18. DOI:
10.1520/D1618-23.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or 6. Sampling
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
6.1 Samples shall be taken in accordance with Practice
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. D1799 or Practice D1900.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
D1618 − 23
7. Standardization of Apparatus 8.9 Check standardization of the spectrophotometer at 425
nm in accordance with Section 7.
7.1 Turn on the spectrophotometer and allow it to warm for
the length of time specified by the manufacturer. 8.10 Pour a portion of filtrate out of the stoppered flask into
a beaker with a pouring lip.
7.2 Check the zero reading of the spectrophotometer in
accordance with the manufacturer’s instructions, and adjust if 8.11 Using a cuvet matched to the one in 7.5, or the same
necessary. cuvet as used in 7.5, rinse and fill the cuvet in the same manner
as in 7.5 and 7.6.
7.3 Place the funnel wi
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D1618 − 18 D1618 − 23
Standard Test Method for
Carbon Black Extractables—Transmittance of Toluene
1
Extract
This standard is issued under the fixed designation D1618; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers the measurement of the degree of toluene discoloration by carbon black extractables and is useful in
controlling the reaction processes for production of carbon black. This test method may not be applicable to carbon blacks with
high extractables.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D1799 Practice for Carbon Black—Sampling Packaged Shipments
D1900 Practice for Carbon Black—Sampling Bulk Shipments
D4483 Practice for Evaluating Precision for Test Method Standards in the Rubber and Carbon Black Manufacturing Industries
3. Terminology
3.1 Definitions:
3.1.1 carbon black toluene discoloration, n— the transmittance, at 425 nm, of the filtrate obtained from the toluene extract of
carbon black, compared to that of pure toluene.
4. Significance and Use
4.1 The toluene discoloration value provides an estimate of toluene-soluble discoloring residues present on the carbon black.
1
This test method is under the jurisdiction of ASTM Committee D24 on Carbon Black and is the direct responsibility of Subcommittee D24.31 on Non-Carbon Black
Components of Carbon Black.
Current edition approved June 1, 2018Nov. 1, 2023. Published July 2018November 2023. Originally approved in 1965. Last previous edition approved in 20172018 as
D1618 – 17.D1618 – 18. DOI: 10.1520/D1618-18.10.1520/D1618-23.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
D1618 − 23
5. Apparatus and Reagent
5.1 Spectrophotometer, with tungsten filament lamp, 20-nm maximum spectral bandpass, capable of measuring percent
transmittance at a 425-nm wavelength. The instrument is to be operated in accordance with the manufacturer’s directions for
optimum performance.
5.2 Cuvets, rectangular, with an optical light path of 10 mm.
5.3 Balance, analytical, with a sensitivity of 60.01 g.
5.4 Oven, gravity-convection type, capable temperature regulation within 61°C at 125°C and temperature uniformity within
65°C.
3
5.5 Pipet, automatic, bottle-type, 20 cm , with a repeatability of 60.1.
3
5.6 Erlenmeyer Flasks, 125 cm with ground-glass stopper.
5.7 Filter Paper, qualitative grade, medium retention, medium-fast filter speed, 150-mm diameter. 150-mm diameter, pore size of
2 to 3 μm.
5.8 Glass Filtering Funnels, 75-mm inside diameter at the top.
3
5.9 Beakers, 50 or 100 cm , with pouring lips.
5.10 Wiping Paper, lint-free.
5.11 Cotton Swabs.
5.12 Fume Hood, fully enclosed on three sides, with spark-proof fan and motor.
5.13 Toluene, analytical reagent grade.
6. Sampling
6.1 Samples shall be taken in accordance with Practice D1799 or Practice D1900.
7. Standardization of Apparatus
7.1 Turn on the spectrophotometer and allow it to warm for the length of time specified by the manufacturer.
7.2 Check the zero reading of the spectrophotometer in accordance with the manufacturer’s instructions, and adjust if necessary.
3
7.3 Place the funnel with the filter paper into an Erlenmeyer flask. Filter approximately 30 cm of toluene into the
...
Questions, Comments and Discussion