Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

ABSTRACT
This specification covers faced or unfaced rigid cellular phenolic thermal insulation. Insulations in the form of boards shall be faced or unfaced, while tubular forms shall be unfaced. This specification does not apply to field expanded cellular phenolic materials. Materials covered by this specification are used as roof insulation; sheathing or rigid board for non-load bearing, building material applications; and pipe insulation for use at specified temperature ranges. Type II Grade 1 and Type III Grade 1 materials with an appropriate vapor retarder covering on the warm surface can be used to a lower temperature limit. The thermal insulation shall be of the following types and grades: Type I, for use as roof insulation board and produced without integral vapor retarder facers; Type II, for use as sheathing or rigid panel for non-load bearing applications and produced with integral vapor retarder facers; Type III, for use as pipe insulation and produced without integral vapor retarder facers; Grade 1, closed cell material; and Grade 2, open cell material. Materials shall be sampled, prepared, tested, and conform accordingly to the following physical properties: density; compressive resistance; tensile strength; apparent thermal conductivity; dimension stability; water absorption; water vapor permeance and permeability; flame spread index; and smoke developed index.
SCOPE
1.1 This specification covers faced or unfaced, rigid cellular phenolic thermal insulation. Boards shall be faced or unfaced. Tubular forms covered by this standard shall be unfaced. It does not apply to field expanded cellular phenolic materials.
Note 1: If a facer or vapor retarder is to be used for the tubular form, then refer to Practice C921.  
1.2 Materials covered by this specification are used as roof insulation; sheathing or rigid board for non-load bearing, building material applications; and pipe insulation for use between −40 and 257°F (−40 and 125°C). Type II and Type III materials with an appropriate vapor retarder covering on the warm surface are used to a lower temperature limit of −290°F (−180°C). (See 7.3.)  
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.4 This specification covers closed cell rigid cellular phenolic thermal insulation manufactured using blowing agents with an ozone depletion potential of 0 (ODP 0).  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
For specific precautionary statements, see Section 16.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
31-Oct-2018
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1126-18 - Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C1126-18 - Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1126 −18
Standard Specification for
Faced or Unfaced Rigid Cellular Phenolic Thermal
1
Insulation
This standard is issued under the fixed designation C1126; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 Thisspecificationcoversfacedorunfaced,rigidcellular
C165TestMethodforMeasuringCompressivePropertiesof
phenolic thermal insulation. Boards shall be faced or unfaced.
Thermal Insulations
Tubular forms covered by this standard shall be unfaced. It
C168Terminology Relating to Thermal Insulation
does not apply to field expanded cellular phenolic materials.
C177Test Method for Steady-State Heat Flux Measure-
NOTE 1—If a facer or vapor retarder is to be used for the tubular form,
ments and Thermal Transmission Properties by Means of
then refer to Practice C921.
the Guarded-Hot-Plate Apparatus
1.2 Materials covered by this specification are used as roof
C209Test Methods for Cellulosic Fiber Insulating Board
insulation; sheathing or rigid board for non-load bearing,
C335/C335MTest Method for Steady-State Heat Transfer
building material applications; and pipe insulation for use
Properties of Pipe Insulation
between−40 and 257°F (−40 and 125°C).Type II andType III
C390Practice for Sampling and Acceptance of Thermal
materials with an appropriate vapor retarder covering on the
Insulation Lots
warm surface are used to a lower temperature limit of −290°F
C518Test Method for Steady-State Thermal Transmission
(−180°C). (See 7.3.)
Properties by Means of the Heat Flow Meter Apparatus
C550Test Method for Measuring Trueness and Squareness
1.3 The values stated in inch-pound units are to be regarded
of Rigid Block and Board Thermal Insulation
as standard. The values given in parentheses are mathematical
C585Practice for Inner and Outer Diameters of Thermal
conversions to SI units that are provided for information only
Insulation for Nominal Sizes of Pipe and Tubing
and are not considered standard.
C921Practice for Determining the Properties of Jacketing
1.4 This specification covers closed cell rigid cellular phe-
Materials for Thermal Insulation
nolic thermal insulation manufactured using blowing agents
C1045Practice for Calculating Thermal Transmission Prop-
with an ozone depletion potential of 0 (ODP 0).
erties Under Steady-State Conditions
C1058/C1058MPractice for Selecting Temperatures for
1.5 This standard does not purport to address all of the
Evaluating and Reporting Thermal Properties of Thermal
safety concerns, if any, associated with its use. It is the
Insulation
responsibility of the user of this standard to establish appro-
C1303/C1303MTest Method for Predicting Long-Term
priate safety, health, and environmental practices and deter-
Thermal Resistance of Closed-Cell Foam Insulation
mine the applicability of regulatory limitations prior to use.
C1363Test Method for Thermal Performance of Building
For specific precautionary statements, see Section 16.
Materials and Envelope Assemblies by Means of a Hot
1.6 This international standard was developed in accor-
Box Apparatus
dance with internationally recognized principles on standard-
C1763Test Method for Water Absorption by Immersion of
ization established in the Decision on Principles for the
Thermal Insulation Materials
Development of International Standards, Guides and Recom-
D1621Test Method for Compressive Properties of Rigid
mendations issued by the World Trade Organization Technical
Cellular Plastics
Barriers to Trade (TBT) Committee.
D1622Test Method for Apparent Density of Rigid Cellular
Plastics
1
This specification is under the jurisdiction of ASTM Committee C16 on
Thermal Insulation and is the direct responsibility of Subcommittee C16.22 on
2
Organic and Nonhomogeneous Inorganic Thermal Insulations. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Nov. 1, 2018. Published December 2018. Originally contactASTM Customer Service at service@astm.org. ForAnnual Book ofASTM
approved in 1989. Last previous edition approved in 2015 as C1126–15. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/C1126-18. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1126−18
D1623Test Method for Tensile and TensileAdhesion Prop- 6.2 Facings—FacingonTypeIImaterialshallbeadheredto
erties of Rigid Cellular Plastics the core stock and suitable for the service intended.They shall
D2126
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1126 − 15 C1126 − 18
Standard Specification for
Faced or Unfaced Rigid Cellular Phenolic Thermal
1
Insulation
This standard is issued under the fixed designation C1126; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers faced or unfaced, rigid cellular phenolic thermal insulation. Boards shall be faced or unfaced.
Tubular forms covered by this standard shall be unfaced. It does not apply to field expanded cellular phenolic materials.
NOTE 1—If a facer or vapor retarder is to be used for the tubular form, then refer to Practice C921.
1.2 Materials covered by this specification are used as roof insulation; sheathing or rigid board for non-load bearing, building
material applications; and pipe insulation for use between −40 and 257°F (−40 and 125°C). Type II and Type III materials with
an appropriate vapor retarder covering on the warm surface are used to a lower temperature limit of −290°F (−180°C). (See 7.3.)
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.4 This specification covers closed cell rigid cellular phenolic thermal insulation manufactured using blowing agents with an
ozone depletion potential of 0 (ODP 0).
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
For specific precautionary statements, see Section 16.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
C165 Test Method for Measuring Compressive Properties of Thermal Insulations
C168 Terminology Relating to Thermal Insulation
C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the
Guarded-Hot-Plate Apparatus
C209 Test Methods for Cellulosic Fiber Insulating Board
C335/C335M Test Method for Steady-State Heat Transfer Properties of Pipe Insulation
C390 Practice for Sampling and Acceptance of Thermal Insulation Lots
C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
C550 Test Method for Measuring Trueness and Squareness of Rigid Block and Board Thermal Insulation
C585 Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe and Tubing
C921 Practice for Determining the Properties of Jacketing Materials for Thermal Insulation
C1045 Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions
C1058/C1058M Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation
C1303/C1303M Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
C1363 Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus
1
This specification is under the jurisdiction of ASTM Committee C16 on Thermal Insulation and is the direct responsibility of Subcommittee C16.22 on Organic and
Nonhomogeneous Inorganic Thermal Insulations.
Current edition approved May 1, 2015Nov. 1, 2018. Published August 2015December 2018. Originally approved in 1989. Last previous edition approved in 20142015
as C1126 – 14.C1126 – 15. DOI: 10.1520/C1126-14.10.1520/C1126-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1126 − 18
C1763 Test Method for Water Absorption by Imm
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.