ASTM A74-05
(Specification)Standard Specification for Cast Iron Soil Pipe and Fittings
Standard Specification for Cast Iron Soil Pipe and Fittings
SCOPE
1.1 This specification covers cast iron soil pipe and fittings for use in gravity flow plumbing, drain, waste and vent sanitary, and storm water applications. It establishes standards covering material, manufacture, mechanical and chemical properties, coating, test methods, inspection, certification, product markings, dimensions, and dimensional tolerances for extra heavy and service cast iron soil pipe and fittings. These pipe and fittings are not intended for pressure applications as the selection of the proper size for sanitary drain, waste, vent, and storm drain systems allows free air space for gravity drainage.
1.2 This specification covers pipe and fittings of the following patterns and, when so designated, shall apply to any other patterns that conform with the applicable requirements given in this specification.
1.2.1 Pipe TablesExtra heavy, 21/ 2 ft (0.75 m), 31/2ft (1.0 m), 5 ft (1.5 m), 10 ft (3.0 m) lengths 1, 2 Service, 21/2 ft (0.75 m), 31/2ft (1.0 m), 5 ft (1.5 m), 10 ft (3.0 m) 1, 2 Outside dimensions (for detailing)X1.1
1.2.2 Fittings Tables1/4 bends; long 1/4 bends 3, 41/4 bends, long low-hub 51/4 bends, low heel; high heel6, 71/4 bends, short sweep; long sweep81/4 bends, reducing long sweep91/5 bends101/6 bends101/8 bends; long 1/8 bends111/16 bends 11Y branches12, 13Y branches, combination 1/8 bends, single14Y branches, combination 1/8 bends, double14Sanitary T branches, single 15Sanitary T branches, double15Sanitary T branches, cleanout 16Tapped sanitary T branches, single17Tapped sanitary T branches, double17T branches, single and double18Tapped T branches, single 19Tapped T branches, double 19T branches, cleanout 20-45 offset fitting21Double hubs 22Long double hubs22Reducers 23Increasers 24, 25P traps 26, 27Deep seal P traps 28Running traps 29Screw plugs (brass) 30Blind plugs 31Iron-body ferrules 32Side inlets Fig. 3Closet bends 33Tapping bosses 34Reducing 1/4 bend SV35Combination Y and 1/8 bend36H branch fitting37
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. Metric conversions in Tables 1 and 2 are to two decimal places; all other metric conversions are rounded to the nearest whole number.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Endorsed by the
Designation: A 74 – 05 Cast Iron Soil Pipe Institute
American Association State
Highway and Transportation Officials Standard
AASHTO No.: M 263-77
Standard Specification for
1
Cast Iron Soil Pipe and Fittings
ThisstandardisissuedunderthefixeddesignationA 74;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscript
epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope
Tables
Sanitary T branches, double 15
1.1 This specification covers cast iron soil pipe and fittings
Sanitary T branches, cleanout 16
for use in gravity flow plumbing, drain, waste and vent
Tapped sanitary T branches, single 17
Tapped sanitary T branches, double 17
sanitary, and storm water applications. It establishes standards
T branches, single and double 18
covering material, manufacture, mechanical and chemical
Tapped T branches, single 19
properties, coating, test methods, inspection, certification, Tapped T branches, double 19
T branches, cleanout 20
product markings, dimensions, and dimensional tolerances for
-45° offset fitting 21
extra heavy and service cast iron soil pipe and fittings. These
Double hubs 22
pipe and fittings are not intended for pressure applications as
Long double hubs 22
Reducers 23
the selection of the proper size for sanitary drain, waste, vent,
Increasers 24, 25
and storm drain systems allows free air space for gravity
P traps 26, 27
drainage. Deep seal P traps 28
Running traps 29
1.2 This specification covers pipe and fittings of the follow-
Screw plugs (brass) 30
ing patterns and, when so designated, shall apply to any other
Blind plugs 31
patternsthatconformwiththeapplicablerequirementsgivenin Iron-body ferrules 32
Side inlets Fig. 3
this specification.
Closet bends 33
1.2.1 Pipe:
Tapping bosses 34
1
Reducing ⁄4 bend SV 35
1
Combination Y and ⁄8 bend 36
Tables
‘H’ branch fitting 37
1 1
Extra heavy, 2 ⁄2 ft (0.75 m), 3 ⁄2 ft (1.0 m), 5 ft 1, 2
(1.5 m), 10 ft (3.0 m) lengths
1 1
Service, 2 ⁄2 ft (0.75 m), 3 ⁄2 ft (1.0 m), 5 ft (1.5 1, 2
1.3 The values stated in inch-pound units are to be regarded
m),10ft(3.0m)
as the standard. The values given in parentheses are for
Outside dimensions (for detailing) X1.1
information only. Metric conversions in Tables 1 and 2 are to
1.2.2 Fittings:
twodecimalplaces;allothermetricconversionsareroundedto
the nearest whole number.
Tables
1 1
⁄4 bends; long ⁄4 bends 3, 4
2. Referenced Documents
1
⁄4 bends, long low-hub 5
2
1
⁄4 bends, low heel; high heel 6, 7
2.1 ASTM Standards:
1
⁄4 bends, short sweep; long sweep 8
A 48/A 48M Specification for Gray Iron Castings
1
⁄4 bends, reducing long sweep 9
A 644 Terminology Relating to Iron Castings
1
⁄5 bends 10
1
⁄6 bends 10
D 1248 Specification for Polyethylene Plastics Extrusion
1 1
⁄8 bends; long ⁄8 bends 11
Materials For Wire and Cable
1
⁄16 bends 11
E8 Test Methods for Tension Testing of Metallic Materials
Y branches 12, 13
3
1
Y branches, combination ⁄8 bends, single 14 2.2 Federal Standard:
1
Y branches, combination ⁄8 bends, double 14
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
Sanitary T branches, single 15
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
1
This specification is under the jurisdiction of ASTM Committee A04 on Iron contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Castings and is the direct responsibility of Subcommittee A04.12 on Pipes and Standards volume information, refer to the standard’s Document Summary page on
Tubes. the ASTM website.
3
Current edition approved June 1, 2005. Published June 2005. Originally Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,
approved in 1917. Last previous edition approved in 2004 as A 74 – 04a. Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
A74–05
3
2.3 Military Standard: 6. Chemical Test for Gray Iron
MIL-STD-129 Marking for Shipment and Storage
6.1 The manufacturer shall perform tests to determine the
4
2.4 ANSI/ASME Standard:
significant chemical constituents of the gray iron used in the
B1.20 Pipe Threads
manufacture of gray iron soil pipe and fittings. Analysis shall
be performed at the minimum of once per lot as defined in this
3. Terminology
specification. The manufacturer shall maintain a record of
3.1 Definitions of Terms Specific to This Standard:
chemical tests performed for a minimum of 7 years. The test
3.2 manufacturer, n—the entity that casts the pipe and
results shall conform to t
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.