ASTM C1277-09a
(Specification)Standard Specification for Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Fittings
Standard Specification for Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Fittings
ABSTRACT
This specification covers the materials and testing of shield hubless couplings to join hubless cast iron soil pipe and fittings. Gaskets shall comply with the required physical and chemical properties, dimensions, and material specifications. The rubber gasket shall conform to the required physical requirements such as tensile strength, elongation, durometer, accelerated aging, compression set, oil immersion, ozone cracking, tear resistance, and water absorption. The shield and clamp assembly shall be made of material conforming to the requirements such as tensile strength and hardness. All parts shall be made of 300 series stainless steel, namely: Type 301; Type 304; Type 300; Type 301; and Type 305. The material shall also undergo physical tests like deflection, shear, and unstrained hydrostatic tests.
SCOPE
1.1 This specification covers the materials and testing of shielded hubless couplings to join hubless cast iron soil pipe and fittings.
1.2 Several different types of hubless couplings are available for use in hubless cast iron sanitary and storm drain, waste and vent piping applications to connect hubless cast iron soil pipe and fittings by using a sleeve-type, or some other type coupling device. It is the purpose of this specification to furnish information as to the characteristics of one such sleeve type couplings when applied to cast iron soil pipe and fittings manufactured in accordance with Specification A888, latest revision, and CISPI-301, latest revision.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 The committee with jurisdiction over this standard is aware of other comparable standard published by the Cast Iron Soil Pipe Institute, CISPI-310, FM 1680 published by Factory Mutual, and Specification C1540 published by ASTM.
1.5 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1277 – 09a
Standard Specification for
Shielded Couplings Joining Hubless Cast Iron Soil Pipe and
1
Fittings
This standard is issued under the fixed designation C1277; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope Fittings for Sanitary and Storm Drain, Waste, and Vent
Piping Applications
1.1 This specification covers the materials and testing of
C564 Specification for Rubber Gaskets for Cast Iron Soil
shielded hubless couplings to join hubless cast iron soil pipe
Pipe and Fittings
and fittings.
C1540 Specification for Heavy Duty Shielded Couplings
1.2 Several different types of hubless couplings are avail-
Joining Hubless Cast Iron Soil Pipe and Fittings
able for use in hubless cast iron sanitary and storm drain, waste
D3677 TestMethodsforRubber—IdentificationbyInfrared
and vent piping applications to connect hubless cast iron soil
Spectrophotometry
pipe and fittings by using a sleeve-type, or some other type
2.2 CISPI Standard:
couplingdevice.Itisthepurposeofthisspecificationtofurnish
CISPI-301 SpecificationforHublessCastIronSoilPipeand
information as to the characteristics of one such sleeve type
Fittings for Sanitary and Storm Drain, Waste and Vent
couplings when applied to cast iron soil pipe and fittings
3
Piping Applications
manufactured in accordance with Specification A888, latest
CISPI-310 Specification for Couplings for Use in Connec-
revision, and CISPI-301, latest revision.
tion with Hubless Cast Iron Soil Pipe and Fittings for
1.3 The values stated in inch-pound units are to be regarded
Sanitary and Storm Drain, Waste, and Vent Piping Appli-
as standard. The values given in parentheses are mathematical
3
cations
conversions to SI units that are provided for information only
FM 1680 Couplings Used in Hubless Cast Iron Systems for
and are not considered standard.
Drain, Waste or Vent, Sewer, Rainwater or Storm Water
1.4 The committee with jurisdiction over this standard is
System,Above or Below Ground, Industrial, Commercial
aware of other comparable standard published by the Cast Iron
4
and Residential
Soil Pipe Institute, CISPI-310, FM 1680 published by Factory
Mutual, and Specification C1540 published by ASTM.
3. Terminology
1.5 The following precautionary caveat pertains only to the
3.1 Definitions:
test method portion, Section 7, of this specification. This
3.1.1 Definitions of the following terms used in this speci-
standard does not purport to address all of the safety concerns,
fication are found in Terminology A644, elastomeric and
if any, associated with its use. It is the responsibility of the user
durometer.
of this standard to establish appropriate safety and health
3.2 Definitions of Terms Specific to This Standard:
practices and determine the applicability of regulatory limita-
3.2.1 center stop, n—an integral part of the gasket centered
tions prior to use.
on the axial length of the gasket intended to limit the insertion
2. Referenced Documents depth of the pipe to be coupled.
2
3.2.2 clamp assembly, n—that portion of the coupling
2.1 ASTM Standards:
excluding the gasket and shield.
A644 Terminology Relating to Iron Castings
3.2.3 corrugated, n—any method of embossing.
A888 Specification for Hubless Cast Iron Soil Pipe and
3.2.4 coupling, n—the complete assembly.
3.2.5 fitting, n—parts of a pipeline other than straight pipes,
valves, or couplings.
1
This specification is under the jurisdiction of ASTM Committee A04 on Iron
3.2.6 gasket, n—the elastomeric portion of the coupling.
Castings and is the direct responsibility of Subcommittee A04.75 on Gaskets and
3.2.7 joint, n—the point of assembly consisting of the
Coupling for Plumbing and Sewer Piping.
Current edition approved Dec. 1, 2009. Published January 2010. Originally
coupling and the joined pipes or fittings, or both.
approved in 1994. Last previous edition approved in 2009 as C1277 – 09. DOI:
10.1520/C1277-09a.
2 3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Available from Cast Iron Soil Pipe Institute (CISPI), 5959 Shallowford Rd.,
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Suite 419, Chattanooga, TN 37421, http://www.cispi.org.
4
Standards volume information, refer to the standard’s Document Summary page on Available from Factory Mutual Research, 1151 Boston-Providence Turnpike,
the ASTM website. Norwood, MA, 02062.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C1277 – 09a
3.2.8 shield, n—an external metallic protective devi
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C1277–09 Designation: C1277 – 09a
Standard Specification for
Shielded Couplings Joining Hubless Cast Iron Soil Pipe and
1
Fittings
This standard is issued under the fixed designation C1277; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers the materials and testing of shielded hubless couplings to join hubless cast iron soil pipe and
fittings.
1.2 Several different types of hubless couplings are available for use in hubless cast iron sanitary and storm drain, waste and
vent piping applications to connect hubless cast iron soil pipe and fittings by using a sleeve-type, or some other type coupling
device. It is the purpose of this specification to furnish information as to the characteristics of one such sleeve type couplings when
appliedtocastironsoilpipeandfittingsmanufacturedinaccordancewithSpecificationA888,latestrevision,andCISPI-301,latest
revision.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.4 The committee with jurisdiction over this standard is aware of other comparable standard published by the Cast Iron Soil
Pipe Institute, CISPI-310, FM 1680 published by Factory Mutual, and Specification C1540 published by ASTM.
1.5 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification. This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
A644 Terminology Relating to Iron Castings
A888 Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping
Applications
C564 Specification for Rubber Gaskets for Cast Iron Soil Pipe and Fittings
C1540 Specification for Heavy Duty Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Fittings Specification for
Heavy Duty Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Fittings
D3677 Test Methods for RubberIdentification by Infrared Spectrophotometry
2.2 CISPI Standard:
CISPI-301 Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping
3
Applications
CISPI-310 Specification for Couplings for Use in Connection with Hubless Cast Iron Soil Pipe and Fittings for Sanitary and
3
Storm Drain, Waste, and Vent Piping Applications
FM 1680 Couplings Used in Hubless Cast Iron Systems for Drain, Waste or Vent, Sewer, Rainwater or Storm Water System,
4
Above or Below Ground, Industrial, Commercial and Residential
3. Terminology
3.1 Definitions:
3.1.1 Definitions of the following terms used in this specification are found in Terminology A644, elastomeric and durometer.
3.2 Definitions of Terms Specific to This Standard:
1
This specification is under the jurisdiction ofASTM CommitteeA04 on Iron Castings and is the direct responsibility of SubcommitteeA04.75 on Gaskets and Coupling
for Plumbing and Sewer Piping.
Current edition approved Sept.Dec. 1, 2009. Published September 2009.January 2010. Originally approved in 1994. Last previous edition approved in 20082009 as
C1277 – 089. DOI: 10.1520/C1277-09a.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from Cast Iron Soil Pipe Institute (CISPI), 5959 Shallowford Rd., Suite 419, Chattanooga, TN 37421, http://www.cispi.org.
4
Available from Factory Mutual Research, 1151 Boston-Providence Turnpike, Norwood, MA, 02062.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C1277 – 09a
3.2.1 center stop, n—anintegralpartofthegasketcenteredontheaxiallengthofthegasketintendedtolimittheinsertiondepth
of the pipe to be coupled.
3.2.2 clamp assembly, n—that portion of the coupling excluding the gasket and shie
...