EN 1427:2007
(Main)Bitumen and bituminous binders - Determination of the softening point - Ring and Ball method
Bitumen and bituminous binders - Determination of the softening point - Ring and Ball method
This European Standard specifies a method for the determination of the softening point of bitumen and bituminous binders in the range of 28 °C to 150 °C.
NOTE The method described is also applicable to bituminous binders that have been recovered from bituminous mixes, e.g. by extraction.
WARNING - Use of this European Standard can involve hazardous materials, operations and equipment. This European Standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this European Standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Bitumen und bitumenhaltige Bindemittel - Bestimmung des Erweichungspunktes - Ring- und Kugel-Verfahren
Bitumes et liants bitumineux - Détermination du point de ramollissement - Méthode Bille et Anneau
La présente Norme européenne prescrit une méthode de détermination du point de ramollissement des bitumes et des liants bitumineux, dans la plage des températures de 30 °C à 150 °C.
NOTE Cette méthode peut également s'appliquer pour les liants bitumineux extraits d'enrobés bitumineux.
AVERTISSEMENT - L'utilisation de la présente Norme européenne peut impliquer l'intervention de produits, d'opérations et d'équipements à caractère dangereux. La présente Norme européenne n'est pas censée aborder tous les problèmes de sécurité concernés par son usage. Il est de la responsabilité de l'utilisateur de consulter et d'établir des règles de sécurité et d'hygiène appropriées et de déterminer l'applicabilité des restrictions réglementaires avant utilisation.
Bitumen in bitumenska veziva - Določanje zmehčišča - Metoda prstana in kroglice
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Bitumen and bituminous binders - Determination of the softening point - Ring and Ball methodBitumes et liants bitumineux - Détermination du point de ramollissement - Méthode Bille et AnneauBitumen und bitumenhaltige Bindemittel - Bestimmung des Erweichungspunktes - Ring- und Kugel-VerfahrenTa slovenski standard je istoveten z:EN 1427:2007SIST EN 1427:2007en91.100.50Veziva. Tesnilni materialiBinders. Sealing materials75.140Voski, bitumni in drugi naftni proizvodiWaxes, bituminous materials and other petroleum productsICS:SIST EN 1427:20001DGRPHãþDSLOVENSKI
STANDARDSIST EN 1427:200701-julij-2007
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 1427March 2007ICS 75.140; 91.100.50Supersedes EN 1427:1999
English VersionBitumen and bituminous binders - Determination of the softeningpoint - Ring and Ball methodBitumes et liants bitumineux - Détermination du point deramollissement - Méthode Bille et AnneauBitumen und bitumenhaltige Bindemittel - Bestimmung desErweichungspunktes - Ring- und Kugel-VerfahrenThis European Standard was approved by CEN on 3 February 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2007 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 1427:2007: E
Characteristics of thermometers.13 Bibliography.14
NOTE 1 Applying the release agent coating is easier when the plate is warmed to approximately 40 °C. NOTE2 Instead of a release agent, other materials, e.g. baking paper, can be used. 6 Apparatus 6.1 Ring and Ball apparatus,
NOTE Either manual, semi-automatic or automatic, comprising the elements given in 6.1.1 to 6.1.9. 6.1.1 Rings, two, square-shouldered, in brass and conforming to the dimensions shown in Figure 1. 6.1.2 Pouring plate, flat, smooth, metal, approximately 50 mm × 75 mm and 1,5 mm to 2,0 mm thick with the edges turned down (see Figure 2) or a ceramic tile 5 mm to 6 mm thick. 6.1.3 Balls, stainless steel, two, (9,50 ± 0,05) mm in diameter, each having a mass of (3,50 ± 0,05) g. 6.1.4 Ball centering guides, brass, two for centring the steel balls, one for each ring. An example of ball centring guide is given in Figure 3. 6.1.5 Ring holder and assembly, stainless steel or brass, with a holder (A) to support the two rings in a horizontal position, conforming to the shape and dimensions shown in Figure 4, supported in the assembly shown in Figure 5. The bottom of the shouldered rings in the ring holder shall be (25,0 ± 0,4) mm above the upper surface of the bottom plate (B) (see Figure 6); the upper edge of the rings shall be (50 ± 3) mm below the surface of the bath liquid. 6.1.6 Bath, glass beaker capable of being heated, with not less than an 85 mm inside diameter and not less than a 120 mm depth from the bottom of the beaker, as shown in Figure 5. NOTE A squat form 600 ml beaker is suitable.
The rotation speed of the stirring bar shall be approximately 100 r/min. NOTE The stirrer blade of the propeller stirrer should preferably be placed at a level between the bottom plate of the the assembly and the bottom of the beaker (see Figure 5). WARNING — If the propeller stirrer is electrically driven, ensure that it is safely earthed. 6.1.9 Semi-automatic or automatic equipment Instead of the apparatus described in 6.1.1 to 6.1.8, a semi-automatic or automatic apparatus may be used (after it has been calibrated). The results obtained shall be the same as with the manual method and shall be within the precision of the manual method. If automatic equipment is used, it shall be calibrated as frequently as necessary, but at least once a year. In case of doubt, the referee method shall be the manual one with the apparatus as shown in Figure 5. NOTE When using an automatic apparatus, it is possible for the ball to trigger the interruption of a ray of light at a distance of (25,0 ± 0,4) mm below the underside of the ring, rather than the ball touching the bottom plate. 7 Preparation and preservation of laboratory samples and test samples Take the laboratory sample in accordance with EN 58 taking all necessary safety precautions and ensuring that the test sample is representative of the laboratory sample from which it is taken. Prepare the test sample in accordance with EN 12594. For modified bitumen the quantity of sample shall be adjusted to fill four rings in case the test has to be repeated (see 8.6, a)). Heat the two brass rings but not the pouring plate, to approximately 90 °C above the expected softening point and place them on the pouring plate treated with the release agent (see NOTE 1 in 5.3). Do not use too much of the release agent to avoid particles in the bath liquid that can interfere with the ray of light if used. Pour a slight excess of the heated bituminous binder into each of the rings, then allow the specimens to cool in ambient air for at least 30 min. For materials that are soft at room temperature, cool the test sample for at least 30 min at an air temperature at least 10 °C below the expected softening point. No more than 4 h shall elapse until completion of the test from the time the test samples are poured.
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.