Specification for masonry units - Part 1: Clay masonry units

This European standard specifies a method for determining the compressive strength of masonry units.

Festlegungen für Mauersteine - Teil 1: Mauerziegel

Spécifications pour éléments de maçonnerie - Partie 1: Briques de terre cuite

Specifikacija za zidake - 1. del: Opečni zidaki

General Information

Status
Not Published
Technical Committee
Current Stage
5060 - Closure of Vote - Formal Approval
Start Date
10-Dec-2014
Due Date
13-Nov-2014
Completion Date
10-Dec-2014

Relations

Buy Standard

Draft
k EN 771-1:2011/kFprA1:2014
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2014
6SHFLILNDFLMD]D]LGDNHGHO2SHþQL]LGDNL
Specification for masonry units - Part 1: Clay masonry units
Festlegungen für Mauersteine - Teil 1: Mauerziegel
Spécifications pour éléments de maçonnerie - Partie 1: Briques de terre cuite
Ta slovenski standard je istoveten z: EN 771-1:2011/FprA1
ICS:
91.100.25 .HUDPLþQLJUDGEHQLL]GHONL Ceramic building products
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
FINAL DRAFT
EN 771-1:2011
NORME EUROPÉENNE
EUROPÄISCHE NORM
FprA1
July 2014
ICS 91.100.25
English Version
Specification for masonry units - Part 1: Clay masonry units
Spécifications pour éléments de maçonnerie - Partie 1: Festlegungen für Mauersteine - Teil 1: Mauerziegel
Briques de terre cuite
This draft amendment is submitted to CEN members for unique acceptance procedure. It has been drawn up by the Technical Committee
CEN/TC 125.
This draft amendment A1, if approved, will modify the European Standard EN 771-1:2011. If this draft becomes an amendment, CEN
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendment
into the relevant national standard without any alteration.

This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language made
by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has
the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 771-1:2011/FprA1:2014 E
worldwide for CEN national Members.

Contents
Page
Foreword .4
1 Modification to the Foreword .5
2 Modification to the Scope .5
3 Modification to Clause 3, Terms and definitions .5
4 Modification to 5.1, General .6
5 Modification to 5.2, LD units .6
6 Modification to 5.2.2.2, Thickness of shells and webs (LD units) .6
7 Modification to 5.2.3.1, Gross dry density (LD units) .6
8 Modification to 5.2.6, Durability (LD units) .6
9 Modification to 5.2.7, Water absorption (LD units) .6
10 Modification to 5.2.8, Active soluble salts content (LD units) .7
11 Modification to 5.2.9, Moisture movement (LD units) .7
12 Addition of a new subclause 5.2.13 .7
13 Modification to 5.3, HD units .7
14 Modification to 5.3.1.1, Dimensions (HD units) .7
15 Modification to 5.3.2, Configuration (HD units) .7
16 Modification to 5.3.3.1, Gross dry density (HD units) .7
17 Modification to 5.3.3.2, Net dry density (HD units) .7
18 Modification to 5.3.4, Compressive strength (HD units) .8
19 Modification to 5.3.9, Active soluble salts content (HD units) .8
20 Addition of a new subclause 5.3.14 .8
21 Modification to Clause 6, Description, designation and classification of clay masonry
units .8
22 Modification to 6.1.1, LD units .8
23 Modification to 6.1.2, HD units .9
24 Addition of a new subclause 6.2 .9
25 Modification to Clause 8, Evaluation of conformity . 12
26 Modification to 8.1, General . 13
27 Modification to 8.2, Initial type testing . 13
28 Modification to 8.3.1, General . 13
29 Modification to 8.3.10, Nonconforming products . 14
30 Modification to Annex A . 14
31 Modification to A.1 . 14
32 Modification to Annex ZA . 17
Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU
Construction Products Regulation . 17
ZA.1 Scope and relevant characteristics . 17
ZA.2 Procedure for AVCP of clay masonry units . 20
ZA.2.1 System(s) of AVCP . 20
ZA.2.2 Declaration of performance (DoP) . 22
ZA.3 CE marking and labelling. 28

Foreword
This document (EN 771-1:2011/FprA1:2014) has been prepared by Technical Committee CEN/TC 125
“Masonry”, the secretariat of which is held by BSI.
This document is currently submitted to the Unique Acceptance Procedure.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Regulation(s).
For relationship with EU Regulation(s), see informative Annex ZA, which is an integral part of this document.
NOTE Due to fact that the Framework Partnership Agreement between the Commission and CEN & CENELEC is not
signed yet, there are currently no New Approach Consultants in place for 2014. Therefore the provisions of CEN-
CENELEC Guide 15 cannot be met.
This shall not prevent the processing of draft standards nor the offering of harmonized standards to the Commission. In
particular, draft standards can be sent to vote without Consultant assessment.
This note will be removed from the Foreword of the finalized publication.

1 Modification to the Foreword
th th
Replace the 5 and 6 paragraphs with the following:
"This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports basic requirements for construction works of the EU
Construction Products Regulation (Regulation (EU) No 305/2011).
For relationship with EU Regulation/Directive(s), see informative Annex ZA, which is an integral part of this
document.".
2 Modifications to the Scope
st
Replace the 1 paragraph with the following:
“This European Standard specifies the characteristics and performance requirements for masonry units
manufactured from clay for which the main intended uses are protected or unprotected masonry structure (see
definitions 3.3 and 3.4) (e.g. facing and rendered masonry, loadbearing or non-loadbearing masonry
structures, including internal linings and partitions, for building and civil engineering).”.
nd
Delete the whole 2 paragraph.
th
Replace the 5 paragraph with the following:
“It provides for the assessment and verification of constancy of performance (AVCP) of the product to this
European Standard.”.
th
Replace the last sentence in the 7 paragraph with the following:
“This European Standard does not include method of measurement of angles and radii characteristics of
specially shaped clay masonry units.”.
3 Modification to Clause 3, Terms and definitions
Replace the existing definition 3.3 with:
“masonry which is protected against water penetration and is not in contact with soil and ground water
Note 1 to entry: It can either be masonry in external walls which is protected, (e.g. by a layer of suitable render or by
cladding), or it can be the inner leaf of a cavity wall or it can be an internal wall. It may or may not be loadbearing.”.
Add the following new term and definition and renumber accordingly.
“3.4
unprotected masonry
masonry which may be exposed to rain, freeze/thaw and/or may be in contact with soil and ground water
without a suitable protection
Note 1 to entry: It can either be masonry in external walls which is fully unprotected, or which is intended to be
provided by a limited protection (e.g. by a thin layer of render). It may or may not be loadbearing”.
Replace the existing term and definition 3.5 (former 3.4) with:
“P unit
clay masonry unit for use in protected masonry”.
Replace the existing term and definition 3.6 (former 3.5) with:
“U unit
clay masonry unit for use in unprotected masonry”.
Add the following term and definition:
“3.39
product type
the set of representative performance levels or classes of a construction product, in relation to its essential
characteristics, produced using a given combination of raw materials or other elements in a specific
production process”.
4 Modification to 5.1, General
In the NOTE, replace “3.10 and 3.11” with “3.11 and 3.12”.
Add a new paragraph after the NOTE:
“In general, for specially shaped masonry units it will be satisfactory to declare the properties as that
determined on units of a rectangular parallelepiped shape and of the same product type which has been
subjected to a similar manufacturing process.”.
st nd
In the 1 sentence of the 2 paragraph, replace “initial type testing” with “product type determination”.
5 Modification to 5.2, LD units
Throughout the standard replace “LD” with “P” and “HD” with “U”.
Replace the title “LD units” with “P units: intended to be used in protected masonry”.
6 Modification to 5.2.2.2, Thickness of shells and webs (LD units)
In the NOTE, replace “intended” with “foreseen”.
7 Modification to 5.2.3.1, Gross dry density (LD units)
st
3”.
In the 1 paragraph, delete “and shall be equal to or less than 1 000 kg/m
8 Modification to 5.2.6, Durability (LD units)
Replace the whole clause with:
“When the intended use of the product provides a complete protection against water penetration, no reference
to freeze/thaw resistance is required (F0).
In countries where there is a requirement for freeze/thaw resistance, it shall be evaluated and declared
according to the provisions valid in the intended place of use of the units.”.
9 Modification to 5.2.7, Water absorption (LD units)
Replace the whole clause with:
“Because of the intended use of P masonry units there are no requirements regarding water absorption.”.
10 Modification to 5.2.8, Active soluble salts content (LD units)
st
Replace the 1 paragraph, Table 1 an
...

Questions, Comments and Discussion