91.100.25 - Terracotta building products
ICS 91.100.25 Details
Terracotta building products
Keramische Materialien und Produkte
Produits de construction en ceramique
Gradbeni izdelki iz terakote
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 91.100.25 - Terracotta building products
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
This document specifies a test method to establish the uplift resistance of installed clay or concrete tiles for roofing, complying with the relevant product standard, EN 490 or EN 1304, which are unfixed or mechanically fixed to the substructure.
NOTE The test method has been developed for clay or concrete tiles for roofing, but can apply to other discontinuously laid small elements, such as: slates; fibre cement slates; stones; and, adopted accordingly, to photovoltaic and solar thermal panels.
The test method is applicable to mechanical fixings such as clips, hooks, screws and nails.
The method is not applicable to fixed tiles having fixing patterns with less than every third tile fixed.
The test method is not applicable to under and over tiles. Examples of these tiles are given in Annex G.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method for determining the moisture expansion of ceramic tiles.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method for the determination of lead and cadmium given off by the ceramic tiles surface.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method for determining the moisture expansion of ceramic tiles.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method for the determination of lead and cadmium given off by the ceramic
tiles surface.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method for determining the freeze/thaw resistance of clay masonry units in one of two categories F1 or F2.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies methods for determining the dimensional characteristics (length, width, thickness, straightness of sides, rectangularity, surface flatness) and the surface quality of ceramic tiles.
Tiles with areas less than 4 cm2 are excluded from measurements of length, width, straightness of sides, rectangularity and surface flatness.
NOTE Spacer lugs and glaze blobs and other irregularities of the sides are intended to be ignored when measuring length, width, straightness of sides, rectangularity, if these are subsequently hidden in the joints after fixing (installation).
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method for determining the freeze/thaw resistance of clay masonry units in one of
two categories F1 or F2.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to all liquid-applied water impermeable products, based on polymer modified cementitious mortars, dispersions and reaction resin coatings, used beneath ceramic tiling, for external tile installations on walls and floors and in swimming pools.
This European Standard gives the terminology concerning the products and specifies the test methods and the values of performance requirements for liquid-applied water impermeable products associated with tile adhesives.
This European Standard specifies the evaluation of conformity and the classification and designation of liquid-applied water impermeable products beneath ceramic tiling.
This European Standard does not contain recommendations for the design and installation of ceramic tiles and grouts in combination with water impermeable products.
NOTE 1 Liquid-applied water impermeable products may also be used beneath other types of tiles (natural and agglomerated stones, etc.), where they do not adversely affect these materials.
NOTE 2 The user of this European Standard should be familiar with normal laboratory practice. This European Standard does not purport to address all the safety problems associated with its use. It is the responsibility of the user to establish appropriate health and safety practices and to ensure compliance with any European and national regulatory conditions.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 10545-3:2018 specifies a method for determining water absorption, apparent porosity, apparent relative density and bulk density of ceramic tiles. This method is applicable to classification of tiles and product specifications.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 10545-13:2016 specifies a test method for determining the chemical resistance of ceramic tiles at room temperature. The method is applicable to all types of ceramic tiles.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
TC - clarification of Units
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
TC - clarification of Units
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
In the masonry unit standards and in national legislation, some properties need to be declared based on a certain fractile and confidence level. To demonstrate compliance with that a statistical tool can be used.
The purpose of this Technical Report is to exemplify how a statistical tool can be used in practice. This document should not contradict nor extend the scope of the work and role of a Notified Body, nor impose additional burdens on the manufacturer, beyond those laid down in the Construction Products Regulation and the product standards.
Mechanical and other properties of building materials and components are in the report described by random variables with a certain type of probability distribution. The popular normal distribution (Laplace-Gauss distribution) is given in Annex A. Normal distribution may be used to approximate many actual symmetrical distributions. When a remarkable asymmetry is observed, then another type of distribution reflecting this asymmetry should be considered, leading to a more complex method to demonstrate compliance with the product standard. More information on the normality test of Shapiro-Wilk is given in Annex D.
- Technical report54 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method for determining the active soluble salts content of clay masonry units.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 10545-14:2015 specifies a method for determining the resistance to stains of the proper surface of ceramic tiles.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method for determining the active soluble salts content of clay masonry units.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements for masonry units manufactured from clay for which the main intended uses are protected or unprotected masonry structure (see definitions 3.3 and 3.4) (e.g. facing and rendered masonry, loadbearing or non-loadbearing masonry structures, including internal linings and partitions, for building and civil engineering).
(...)
This European Standard includes those clay masonry units of an overall non-rectangular parallelepiped shape.
It defines the performance related to e.g. dimensional tolerances, strength, density measured according to the corresponding test methods contained in separate European Standards.
It provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard.
The marking requirement for products covered by this European Standard is included.
This European Standard does not specify standard sizes for clay masonry units, nor does it specify standard work dimensions, angles and radii of specially shaped clay masonry units. This European Standard does not include method of measurement of angles and radii characteristics of specially shaped clay masonry units.
This European Standard does not cover requirements for the following: units for paving, flue liners and storey height clay masonry units and clay masonry units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire. It does, however, include clay masonry units for external chimney masonry.
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements for masonry units manufactured from clay for which the main intended uses are protected or unprotected masonry structure (see definitions 3.3 and 3.4) (e.g. facing and rendered masonry, loadbearing or non-loadbearing masonry structures, including internal linings and partitions, for building and civil engineering).
(...)
This European Standard includes those clay masonry units of an overall non-rectangular parallelepiped shape.
It defines the performance related to e.g. dimensional tolerances, strength, density measured according to the corresponding test methods contained in separate European Standards.
It provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard.
The marking requirement for products covered by this European Standard is included.
This European Standard does not specify standard sizes for clay masonry units, nor does it specify standard work dimensions, angles and radii of specially shaped clay masonry units. This European Standard does not include method of measurement of angles and radii characteristics of specially shaped clay masonry units.
This European Standard does not cover requirements for the following: units for paving, flue liners and storey height clay masonry units and clay masonry units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire. It does, however, include clay masonry units for external chimney masonry.
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements of calcium silicate masonry units for which the main intended uses are inner walls, outer walls, cellars, foundations and external chimney masonry.
This European Standard is intended to apply to all calcium silicate masonry units, including those of an overall nonrectangular parallelepiped shape, specially shaped and accessory units.
It defines the performance related to e.g. strength, density and dimensional accuracy, measured according to the corresponding test methods contained in separate European Standards.
It provides for the !assessment and verification of constancy of performance (AVCP)" of the product to this European Standard. The marking requirement for products covered by this document is also included.
This European Standard does not specify standard sizes for calcium silicate masonry units, nor standard work dimensions and angles of specially shaped and accessory units.
It does not cover units with more than 60 % volume of voids, nor products made from shale as a major raw material.
It does not cover storey height panels.
It does not cover units intended for use as a damp proof course, nor units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire, nor chimney flue units.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method for determining the compressive strength of masonry units.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 10545-1:2014 specifies rules for batching, sampling, inspection, and acceptance/rejection of ceramic tiles.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 10545-8:2014 defines a test method for determining the coefficient of linear thermal expansion of ceramic tiles.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for clay roofing tiles and fittings for pitched roof coverings and wall cladding and lining. It applies to all tiles and fittings as defined in Clause 3. Clay roofing tiles and clay fittings which conform to this European Standard are suitable for use as roof coverings, vertical wall cladding and lining. This European Standard defines the minimum requirements for a product which if satisfactory at the time of delivery will ensure that the product is able to perform its function in relation to the performance levels declared for it, whilst subjected to the changes that occur in such materials during normal conditions of use. The results obtained according to the European Standard apply to products at the time they are offered for sale.
- National annex2 pagesSlovenian languagesale 10% offe-Library read for1 day
ISO 15045-9:2013 specifies a test method for determining the resistance to thermal shock of all ceramic tiles under normal conditions of use.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for clay roofing tiles and fittings for pitched roof coverings and wall cladding and lining. It applies to all tiles and fittings as defined in Clause 3. Clay roofing tiles and clay fittings which conform to this European Standard are suitable for use as roof coverings, vertical wall cladding and lining. This European Standard defines the minimum requirements for a product which if satisfactory at the time of delivery will ensure that the product is able to perform its function in relation to the performance levels declared for it, whilst subjected to the changes that occur in such materials during normal conditions of use. The results obtained according to the European Standard apply to products at the time they are offered for sale.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for clay roofing tiles and fittings for pitched roof coverings and wall cladding and lining.
It applies to all tiles and fittings as defined in Clause 3.
Clay roofing tiles and clay fittings which conform to this European Standard are suitable for use as roof coverings, vertical wall cladding and lining.
This European Standard defines the minimum requirements for a product which if satisfactory at the time of delivery will ensure that the product is able to perform its function in relation to the performance levels declared for it, whilst subjected to the changes that occur in such materials during normal conditions of use.
The results obtained according to the European Standard apply to products at the time they are offered for sale.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the test method for the determination of frost resistance of clay roofing tiles and fittings. The test method is applicable in all CEN member countries in accordance with the required performance level of each member state.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the test method for the determination of frost resistance of clay roofing tiles and fittings.
The test method is applicable in all CEN member countries in accordance with the required performance level of each member state.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the methods for determining the geometric characteristics of clay tiles as defined in EN 1304, Clay roofing tiles and fittings Product definitions and specifications.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 10545-16:2010 describes a method for utilizing colour measuring instruments for quantifying the small colour differences between plain coloured ceramic tiles, which are designed to be of uniform and consistent colour. It permits the specification of a maximum acceptable value, which depends only on the closeness of match and not on the nature of the colour difference.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 10545-6:2010 specifies a test method for determining the resistance to deep abrasion of all unglazed ceramic tiles used for floor coverings.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the methods for determining the geometric characteristics of clay tiles as defined in EN 1304, Clay roofing tiles and fittings - Product definitions and specifications.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method of determining the freeze-thaw resistance of calcium silicate masonry units.
- Standard7 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method of determining the overall dimensions, thickness and combined thickness of shells and webs, depth of voids and plane parallelism of the bed faces of masonry units.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for clay/ceramic flue blocks with solid walls or walls with vertical perforations including bonding and non-bonding blocks and their fittings. Non-bonding flue blocks which have insulation in the vertical perforations or attached to the outer walls are also covered by this standard. This standard specifies the performance requirements for factory-made flue blocks.
When they are installed, they will form a part of a multi-wall chimney or a complete chimney which will serve to convey products of combustion from fireplaces or heating appliances to the atmosphere.
This standard includes components used for domestic and industrial chimneys which are not structurally independent (free-standing). Testing, marking and inspection requirements are covered by this standard.
NOTE 1 Flue blocks covered by this standard are manufactured in three forms :
a) single flue ;
b) multi-flue ;
c) flue/ventilation combination.
NOTE 2 Flue blocks may have flues which are either circular, square or rectangular. The joints may have a locating feature such as a rebate.
- Standard59 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for clay/ceramic flue blocks with solid walls or walls with vertical perforations including bonding and non-bonding blocks and their fittings. Non-bonding flue blocks which have insulation in the vertical perforations or attached to the outer walls are also covered by this standard. This standard specifies the performance requirements for factory-made flue blocks.
When they are installed, they will form a part of a multi-wall chimney or a complete chimney which will serve to convey products of combustion from fireplaces or heating appliances to the atmosphere.
This standard includes components used for domestic and industrial chimneys which are not structurally independent (free-standing). Testing, marking and inspection requirements are covered by this standard.
NOTE 1 Flue blocks covered by this standard are manufactured in three forms :
a) single flue ;
b) multi-flue ;
c) flue/ventilation combination.
NOTE 2 Flue blocks may have flues which are either circular, square or rectangular. The joints may have a locating feature such as a rebate.
- Standard59 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard describes two test methods for testing the impermeability to water of clay roof tiles and fittings which can be considered as equivalent.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard describes two test methods for testing the impermeability to water of clay roof tiles and fittings which can be considered as equivalent.
NOTE The methods are not applicable to all fittings, because of their different shapes.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
The aim of this European Prestandard is to give general rules to be followed in the design and installation of ceramic tiling. Therefore this prestandard shall not be considered as a substitute for existing national codes of practice containing more detailed rules specific to the respective countries. This prestandard deals with the design and installation of internal and external wall and floor tiling.
- Technical report25 pagesEnglish languagesale 10% offe-Library read for1 day
Gives a method for determining the resistance to surface abrasion of all glazed ceramic tiles used for floor covering.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard describes the test method used to evaluate the flexural strength of clay roofing tiles as defined in the standard EN YY - 'Clay roofing tiles - Product definitions and specifications'.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies a method for determining the frost resistance of all ceramic tiles intended for use in freezing conditions in the presence of water.
- Standard5 pagesEnglish languagesale 10% offe-Library read for1 day
Defines a test method for determining the crazing resistance of all glazed ceramic tiles except when the crazing is an inherent decorative feature of the product.
- Standard5 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard describes the test method used to evaluate the flexural strength of clay roofing tiles as defined in the standard EN YY - 'Clay roofing tiles - Product definitions and specifications'.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to all liquid-applied water impermeable products, based on polymer modified cementitious mortars, dispersions and reaction resin coatings, used beneath ceramic tiling, for external tile installations on walls and floors and in swimming pools.
This document specifies the essential characteristics, the respective threshold levels and test methods for liquid-applied water impermeable products associated with tile adhesives.
This document specifies the assessment and verification of constancy of performance, of liquid-applied water impermeable products beneath ceramic tiling.
NOTE This document does not contain recommendations for the design and installation of ceramic tiles and grouts in combination with water impermeable products.
- Draft28 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to all liquid-applied water impermeable products, based on polymer modified cementitious mortars, dispersions and reaction resin coatings, used beneath ceramic tiling, for external tile installations on walls and floors and in swimming pools.
This document specifies the essential characteristics, the respective threshold levels and test methods for liquid-applied water impermeable products associated with tile adhesives.
This document specifies the assessment and verification of constancy of performance, of liquid-applied water impermeable products beneath ceramic tiling.
NOTE This document does not contain recommendations for the design and installation of ceramic tiles and grouts in combination with water impermeable products.
- Draft28 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the methods for determining the geometric characteristics of clay tiles as defined in EN 1304, Clay roofing tiles and fittings - Product definitions and specifications.
- Draft19 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the characteristics for clay blocks in concrete ribbed floor systems. It specifies two types of clay blocks:
- clay blocks for load-bearing"structural" use (semi-resisting clay blocks and resisting clay blocks)) with essential characteristics:
- detailing:
- dimensions;
- minimum dimensions;
- configuration;
- density;
- mechanical strength:
- punching (resistance to concentrated loads);
- longitudinal compressive strength;
- bending strength;
- fire:
- resistance to fire;
- reaction to fire;
- thermal conductivity;
and:
- clay blocks for non-load bearing-non-structural or light structural- use (low non-resisting clay blocks or non-resisting clay blocks) with essential characteristics:
- detailing:
- dimensions;
- minimum dimensions;
- configuration;
- density;
- mechanical strength:
- punching (resistance to concentrated loads);
- fire:
- resistance to fire;
- reaction to fire;
- thermal conductivity.
The clay blocks are used with floor plates (EN 13747:2005+A2:2010) and in situ concrete, or only with in situ concrete for the construction of ribbed floor systems.
It includes the test/assessment methods and the way of expressing the test/assessment results.
It provides for the assessment and verification of constancy of performance (AVCP) of the product to maintain the performances related to the declared essential characteristics.
This document does not cover characteristics for clay blocks foreseen for beam-and-block floor systems as covered by EN 15037-3:2009+A1:2011.
- Draft36 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements for non-loadbearing (low non-resisting or non-resisting) or loadbearing (semi-resisting or resisting) clay blocks for the use in floor plates.
It defines the performance related to e.g. dimensional tolerances, strength, density measured according to the corresponding test methods contained in separate European Standards.
It provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard.
This European Standard does not cover requirements for clay blocks foreseen for beam-and-block floor systems.
- Draft36 pagesEnglish languagesale 10% offe-Library read for1 day