Abstract

This document specifies the dimensions, linear resistance, mechanical characteristics, construction and mass of lightweight conductors, normal and tight tolerances, in copper or copper alloy for electrical cables for aerospace applications.
It applies to stranded conductors, with a nominal cross-sectional area of 0,15 mm2 to 14 mm2 inclusive.
The conductors for thermocouple extension and fire-resistant cables are not covered by this document.

Status
Not Published
Publication Date
10-May-2027
Technical Committee
ASD-STAN - Aerospace
Current Stage
4599 - Dispatch of FV draft to CMC - Finalization for Vote
Start Date
28-Sep-2026
Completion Date
28-Sep-2026

Buy Documents

FprEN 4434 is a CEN draft European Standard for aerospace-series lightweight conductors made from copper or copper alloy for electrical cables. It specifies the dimensions, linear resistance, mechanical characteristics, construction and mass of stranded conductors with normal and tight tolerances, so manufacturers, test labs and buyers can describe and verify the same conductor types in the same way.

What does FprEN 4434 specify?

FprEN 4434 specifies stranded lightweight conductors for aerospace electrical cables with a nominal cross-sectional area from 0.15 mm2 to 14 mm2 inclusive. It covers normal and tight tolerances, and it excludes conductors for thermocouple extension and fire-resistant cables.

The standard is organized into these main clauses:

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Conductor materials and construction
  • 5 Required characteristics
  • 6 Test methods
  • 7 Designation
  • 8 Marking, packaging and delivery lengths

That structure matters in practice because it separates what the product is, how it is built, how it is measured, and how it is identified when it is delivered.

What are the key requirements of FprEN 4434?

FprEN 4434 sets the material, construction and acceptance limits for aerospace lightweight conductors. The most important points are in Clauses 4, 5, 6 and 8.

Materials and plating

FprEN 4434 requires strands made from high-conductivity annealed electrolytic copper or copper alloy. For nominal cross-sectional areas 0.15 mm2 and 0.25 mm2, the conductor shall be made from copper alloy.

Individual strands may be uncoated or plated with tin, silver or nickel. Silver and nickel platings have minimum thickness values, and tin plating must be thick enough to pass the specified plating tests. In practice, plating choice affects corrosion behavior, surface protection and suitability for termination.

Mechanical and material properties

FprEN 4434 requires elongation prior to rupture of at least 10% for each copper strand and for stranded copper conductors. It also sets a minimum tensile strength for each copper strand. For the copper alloy sizes 0.15 mm2 and 0.25 mm2, the alloy must meet stated resistivity, tensile strength and elongation limits.

These requirements matter because they control how the conductor behaves during drawing, stranding, stripping and crimping, and they help prevent brittle or weak conductors from entering aerospace wiring.

Construction and lay

FprEN 4434 limits how the strands are laid up. Up to 9 mm2, concentric conductors are used, and for 14 mm2 the conductor may be concentric or bunched. The outer layer shall be left-hand laid.

The standard also requires that conductors be free from joints, although individual strands may contain soldered or brazed joints. For strands of 0.25 mm diameter or more, butt joints are required, and joint spacing within individual strands must exceed 3 m. Compaction that deforms strands or damages plating is not permitted.

Required characteristics and tolerances

FprEN 4434 gives two sets of limits: normal tolerances in Table 1 and tight tolerances in Table 2. If the product standard does not say otherwise, normal tolerances apply.

The tables define the conductor code, strand count, diameter range, linear resistance at 20 °C, breaking load and mass. This is the core selection data for design and purchasing, because it lets a user choose the conductor size that matches the electrical and mechanical need.

Testing, designation, and delivery

FprEN 4434 requires tests to be carried out using EN 3475-100 methods. Delivery identification is completed with the length, date and inspection mark, and conductors are supplied on spools or reels with suitable protection.

That means suppliers need traceable delivery documentation, and users need to check that the supplied lengths and packaging match the order.

What terms does FprEN 4434 define?

FprEN 4434 uses the terms, definitions and symbols given in EN 3475-100 for conductors. The following terms are central to the standard:

  • Conductor - the stranded copper or copper alloy product covered by the standard.
  • Normal tolerances - the default set of dimensional and performance limits in Table 1.
  • Tight tolerances - the narrower set of limits in Table 2.
  • Lay length - the helical length of one strand turn in the conductor construction.
  • Compaction - any action that deforms strands or damages plating, which is not allowed.
  • Plating - a surface coating such as tin, silver or nickel applied to individual strands.
  • AWG - American Wire Gage; the tables give the closest AWG equivalent.

Who uses FprEN 4434?

FprEN 4434 is used by aerospace cable manufacturers, conductor suppliers, aircraft electrical system designers, test laboratories and quality personnel. It is also used by procurement teams that need to specify conductor size, plating, tolerance class and delivery form.

In practice, it supports design selection, incoming inspection, type testing, production control and contract specification for aerospace electrical cables.

What changed in FprEN 4434 from the previous edition?

FprEN 4434 supersedes EN 4434:2005. The draft states three significant technical changes:

  • an added minimum elongation prior to rupture requirement for stranded copper conductor in Clause 4.3
  • an added minimum breaking load of 1000 N for the 9 mm section in Table 1
  • an added minimum breaking load of 1000 N for the 9 mm section in Table 2

Which standards are used with FprEN 4434?

StandardContribution to FprEN 4434
EN 3475-100General test methods, and the terms, definitions and symbols used for conductors
EN 3475-506Plating continuity test
EN 3475-507Plating adherence test
IEC 60344Procedure for calculating resistance for codes 090 and 140
EN 3475-301Formulae for resistance at other temperatures
IEC 60028Material reference for high-conductivity annealed electrolytic copper
EN 2083Matching minimum diameter and mass values to existing stripping and crimping tooling

What does the FprEN 4434 document contain?

FprEN 4434 contains two main product tables, one for normal tolerances and one for tight tolerances. Those tables provide the conductor codes, strand counts, diameter limits, linear resistance, breaking load and mass values that designers and buyers use to select a conductor.

The document also includes construction rules for materials, plating, lay length, joints and compaction, plus test-method references for checking compliance. Clause 7 gives the designation format, and Clause 8 covers marking, packaging and delivery lengths.

It also gives calculation notes for resistance at other temperatures and for the larger code sizes that use the IEC 60344 procedure. That makes the document useful not only for procurement, but also for engineering calculations, conformity assessment and production inspection.

Relations

Effective Date
23-Jul-2025

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

BUREAU VERITAS Certification Germany

Bureau Veritas certification in Germany.

DAKKS Germany Verified

Element Materials Technology

Materials testing and product certification.

UKAS United Kingdom Verified

AQMS Ltd.

AQMS provides ISO certification to SMEs across the UK.

UKAS United Kingdom Verified

Sponsored listings

Frequently Asked Questions

FprEN 4434 is a draft published by the European Committee for Standardization (CEN). Its full title is "Aerospace series - Copper or copper alloy lightweight conductors for electrical cables - Product standard (Normal and tight tolerances)". This standard covers: This document specifies the dimensions, linear resistance, mechanical characteristics, construction and mass of lightweight conductors, normal and tight tolerances, in copper or copper alloy for electrical cables for aerospace applications. It applies to stranded conductors, with a nominal cross-sectional area of 0,15 mm2 to 14 mm2 inclusive. The conductors for thermocouple extension and fire-resistant cables are not covered by this document.

This document specifies the dimensions, linear resistance, mechanical characteristics, construction and mass of lightweight conductors, normal and tight tolerances, in copper or copper alloy for electrical cables for aerospace applications. It applies to stranded conductors, with a nominal cross-sectional area of 0,15 mm2 to 14 mm2 inclusive. The conductors for thermocouple extension and fire-resistant cables are not covered by this document.

FprEN 4434 is classified under the following ICS (International Classification for Standards) categories: 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.

FprEN 4434 has the following relationships with other standards: It is inter standard links to EN 4434:2005. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

FprEN 4434 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2025
Aeronavtika - Lahki vodniki iz bakra ali bakrenih zlitin za električne kable -
Standard za proizvod (običajne in ozke tolerance)
Aerospace series - Copper or copper alloy lightweight conductors for electrical cables -
Product standard (Normal and tight tolerances)
Luft- und Raumfahrt - Leichter Leiter aus Kupfer oder Kupferlegierung für elektrische
Leitungen - Produktnorm (Normale und enge Toleranzen)
Série aérospatiale - Conducteurs a tolérances réduites en cuivre ou alliage de cuivre
pour câbles électriques - Norme de produit (Tolérances normales et réduites)
Ta slovenski standard je istoveten z: prEN 4434
ICS:
29.060.20 Kabli Cables
49.060 Letalska in vesoljska Aerospace electric
električna oprema in sistemi equipment and systems
77.150.30 Bakreni izdelki Copper products
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

DRAFT
EUROPEAN STANDARD
prEN 4434
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2025
ICS 49.060 Will supersede EN 4434:2005
English Version
Aerospace series - Copper or copper alloy lightweight
conductors for electrical cables - Product standard
(Normal and tight tolerances)
Luft- und Raumfahrt - Leichter Leiter aus Kupfer oder
Kupferlegierung für elektrische Leitungen -
Produktnorm (Normale und enge Toleranzen)
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee ASD-
STAN.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 4434:2025 E
worldwide for CEN national Members.

prEN 4434:2025 (E)
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Conductor materials and construction . 4
4.1 Materials . 4
4.2 Metal plating . 4
4.3 Electrolytic copper . 5
4.4 Copper alloy . 5
4.5 Construction of conductors . 5
4.5.1 Lay length . 5
4.5.2 Joints . 6
4.5.3 Compaction . 6
5 Required characteristics . 6
5.1 General. 6
5.2 Normal tolerances . 6
5.3 Tight tolerances . 8
6 Test methods . 8
7 Designation . 9
8 Marking, packaging and delivery lengths . 9
Bibliography . 10

prEN 4434:2025 (E)
European foreword
This document (prEN 4434:2025) has been prepared by ASD-STAN.
After enquiries and votes carried out in accordance with the rules of this Association, this document has
received the approval of the National Associations and the Official Services of the member countries of
ASD-STAN, prior to its presentation to CEN.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 4434:2005.
prEN 4434:2025 includes the following significant technical changes with respect to EN 4434:2005:
— addition of: “The elongation prior to rupture, for stranded copper conductor, shall not be less than
10 %.” in 4.3;
— in Table 1, addition the minimal breaking load for 9 mm section is “1000N”;
— in Table 2, addition the minimal breaking load for 9 mm section is “1000N”.
prEN 4434:2025 (E)
1 Scope
This document specifies the dimensions, linear resistance, mechanical characteristics, construction and
mass of lightweight conductors, normal and tight tolerances, in copper or copper alloy for electrical
cables for aerospace applications.
2 2
It applies to stranded conductors, with a nominal cross-sectional area of 0,15 mm to 14 mm inclusive.
The conductors for thermocouple extension and fire-resistant cables are not covered by this document.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edi
...