Plastics piping systems - Soil and waste discharge systems within the building structure - Performance characteristics for pipes, fittings and their joints

This document specifies performance requirements for non-pressure plastics pipes, fittings and their joints intended for soil and waste applications:
-   inside the building (application area code "B"),
-   buried in ground within the building structure (application area code "BD") and with a diameter greater than or equal to 75 mm,
and gives associated test methods for verification and evaluation of conformity with this document.

Kunststoff-Rohrleitungssysteme - Rohrleitungssysteme zum Ableiten von Abwasser innerhalb der Gebäudestruktur - Eigenschaften für die Gebrauchstauglichkeit von Rohren, Formstücken und deren Verbindungen

Dieses Dokument legt Leistungsanforderungen für drucklos betriebene Rohre, Formstücke und deren Verbindungen aus Kunststoff fest, die vorgesehen sind für:
   Abwasserleitungen innerhalb von Gebäuden (Anwendungskennzeichen B);
   erdverlegte Abwasserleitungen innerhalb der Gebäudestruktur (Anwendungskennzeichen BD) mit einem Durchmesser von  75 mm;
und enthält damit verbundene Prüfverfahren zum Nachweis und zur Bewertung der Konformität mit diesem Dokument.

Systèmes de canalisations en plastique - Systèmes pour l'évacuation des eaux-vannes et des eaux usées à l'intérieur de la structure des bâtiments - Caractéristiques de performance pour tubes, raccords et leurs assemblages

Le présent document spécifie les exigences de performance pour les tubes, les raccords et leurs assemblages, en plastique, sans pression destinés aux applications pour eaux-vannes et eaux usées :
   à l'intérieur du bâtiment (code de zone d’application «B») ;
   enterrées dans la structure du bâtiment (code de zone d’application «BD») et de diamètre supérieur ou égal à 75 mm ;
et indique les méthodes associées pour la vérification et l’évaluation de la conformité au présent document.

Cevni sistemi iz polimernih materialov - Odvodni sistemi v zgradbah - Lastnosti cevi, fitingov in njihovih spojev

General Information

Status
Withdrawn
Publication Date
23-Oct-2007
Withdrawal Date
14-Apr-2020
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
15-Apr-2020

Relations

Buy Standard

Standard
EN 15012:2008
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Plastics piping systems - Soil and waste discharge systems within the building structure - Performance characteristics for pipes, fittings and their jointsCevni sistemi iz polimernih materialov -
Odvodni sistemi v zgradbah - Lastnosti cevi, fitingov in njihovih spojevSystemes de canalisations en plastique - Systemes pour l'évacuation des eaux-vannes et des eaux usées a l'intérieur de la structure des bâtiments - Caractéristiques de performance pour tubes, raccords et leurs assemblagesKunststoff-Rohrleitungssysteme - Rohrleitungssysteme zum Ableiten von Abwasser innerhalb der Gebäudestruktur - Eigenschaften für die Gebrauchstauglichkeit von Rohren, Formstücken und deren VerbindungenTa slovenski standard je istoveten z:EN 15012:2007SIST EN 15012:2008en,fr,de91.140.80Drenažni sistemiDrainage systems23.040.45Fitingi iz polimernih materialovPlastics fittings23.040.20Cevi iz polimernih materialovPlastics pipesICS:SLOVENSKI
STANDARDSIST EN 15012:200801-januar-2008

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15012October 2007ICS 23.040.01; 91.140.80 English VersionPlastics piping systems - Soil and waste discharge systemswithin the building structure - Performance characteristics forpipes, fittings and their jointsSystèmes de canalisations en plastique - Systèmes pourl'évacuation des eaux-vannes et des eaux usées àl'intérieur de la structure des bâtiments - Caractéristiquesde performance pour tubes, raccords et leurs assemblagesKunststoff-Rohrleitungssysteme - Rohrleitungssystemezum Ableiten von Abwasser innerhalb der Gebäudestruktur- Eigenschaften für die Gebrauchstauglichkeit von Rohren,Formstücken und deren VerbindungenThis European Standard was approved by CEN on 23 August 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2007 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15012:2007: E

Mounting and fixing of components in the test apparatus
according to
EN 13823 14 Annex B (normative)
Product standards for soil and waste discharge piping systems in plastics materials 16 Annex C (normative)
Standards for assessment of conformity for soil and waste discharge piping systems in plastics materials 17 Annex ZA (informative)
Clauses of this European Standard addressing the provisions of
the EU Construction Products Directive 18 ZA.1 Scope and relevant characteristics 18 ZA.2 Procedure for attestation of conformity of plastics pipes and fittings 20 ZA.3 CE marking and labelling 23 Bibliography 27

Material independent
Specific solutions
Figure 1
Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 1: Vulcanised rubber EN 681-2,
Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 2: Thermoplastic elastomers EN 681-3,
Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 3: Cellular materials of vulcanised rubber EN 681-4,
Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 4: Cast polyurethane sealing elements EN 1053,
Plastics piping systems — Thermoplastics piping systems for non-pressure applications — Test method for watertightness EN 1054,
Plastics piping systems — Thermoplastics piping systems for soil and waste discharge — Test method for airtightness of joints EN 1055,
Plastics piping systems — Thermoplastics piping systems for soil and waste discharge inside buildings — Test method for resistance to elevated temperature cycling EN 13501-1,
Fire classification of construction products and building elements — Part 1: Classification using test data from reaction to fire tests EN 13823,
Reaction to fire tests for building products — Building products excluding floorings exposed to the thermal attack by a single burning item EN ISO 3126,
Plastics piping systems — Plastics components — Determination of dimensions (ISO 3126:2005) EN ISO 9001:2000, Quality management systems — Requirements (ISO 9001:2000) EN ISO 9969, Thermoplastics pipes — Determination of ring stiffness (ISO 9969:1994) ISO 13966, Thermoplastics pipes and fittings — Nominal ring stiffnesses ISO 13967,
Thermoplastics fittings — Determination of ring stiffness

It is designated by the letters "SN" followed by the appropriate number. 4 Performance requirements 4.1 Reaction to fire for applications inside building Products conforming to this document shall be classified according to 5.1. 4.2 Dimensional tolerances The manufacturer shall declare the dimensional tolerances for the jointing of the components either by means of: a) reference to an appropriate European product standard given in Annex B, or b) in the absence of a European Standard, reference to a specific European product specification published by a recognized European organization, or c) in the absence of a) and b) reference to an International Standard, or
d) in the absence of a), b), and c), by stating the values of his own specification and associated jointing method. Dimensions shall be measured in accordance with 5.2 and shall be within the declared tolerances. 4.3 Tightness (air and liquid) 4.3.1 Tightness of elastomeric sealing ring joints The tightness of the jointed system shall be tested in accordance with 5.3 for sealing ring joints and the following shall apply:  no water leakage shall occur;  no air leakage shall occur.

≤ 3 mm;  DN > 50:
0,05 × dn mm. 4.4.2 Durability of elastomeric sealing joints The tightness of elastomeric sealing joints shall be deemed to be durable if the sealing element conforms to
EN 681-1, EN 681-2, EN 681-3 or EN 681-4, as applicable. 4.5 Maximum load for admissible deformation for pipes and fittings for applications buried in ground within the building structure 4.5.1 General For the intended end use buried in ground within the building structure, the maximum load for admissible deformation shall be addressed as ring stiffness. Ring stiffness shall be determined either by calculation or as described in 4.5.2 and 4.5.3. 4.5.2 Ring stiffness of pipes The ring stiffness of a thermoplastics pipe shall be determined in accordance with 5.5.1 and shall be expressed either as SN 2, SN 4, SN 8 or SN 16 following ISO 13966, as applicable, or as the actual value obtained in the test, expressed in kN/m2. 4.5.3 Stiffness of fittings The stiffness of a fitting made from the same material and having the same wall thickness and design as a corresponding pipe shall because of its geometry be deemed to have at least the same as the stiffness as that pipe. For other constructions the ring stiffness of bends and branches with the largest side branch shall be measured in accordance with 5.5.2. Based on the obtained lowest value of the result other fittings of the same design family can be classified with the same stiffness class. The ring stiffness of a thermoplastics fitting shall be expressed either as SN 2, SN 4, SN 8 or SN 16 following ISO 13966, as applicable, or as the actual value obtained in the test, expressed in kN/m2. The fittings manufacturer shall declare for which pipe stiffness classes the product is suitable. NOTE This clause is only applicable for components intended to be used buried in ground within the building structure and with a nominal outside diameter greater than or equal to 75 mm.
...