Plastics piping systems - Soil and waste discharge systems within the building structure - Performance characteristics for pipes, fittings and their joints

This document specifies performance requirements for non-pressure plastics pipes, fittings and their joints intended for soil and waste applications:
-   inside the building (application area code "B"),
-   buried in ground within the building structure (application area code "BD") and with a diameter greater than or equal to 75 mm,
and gives associated test methods for verification and evaluation of conformity with this document.

Kunststoff-Rohrleitungssysteme - Rohrleitungssysteme zum Ableiten von Abwasser innerhalb der Gebäudestruktur - Eigenschaften für die Gebrauchstauglichkeit von Rohren, Formstücken und deren Verbindungen

Dieses Dokument legt Leistungsanforderungen für drucklos betriebene Rohre, Formstücke und deren Verbindungen aus Kunststoff fest, die vorgesehen sind für:
   Abwasserleitungen innerhalb von Gebäuden (Anwendungskennzeichen B);
   erdverlegte Abwasserleitungen innerhalb der Gebäudestruktur (Anwendungskennzeichen BD) mit einem Durchmesser von  75 mm;
und enthält damit verbundene Prüfverfahren zum Nachweis und zur Bewertung der Konformität mit diesem Dokument.

Systemes de canalisations en plastique - Systemes pour l'évacuation des eaux-vannes et des eaux usées a l'intérieur de la structure des bâtiments - Caractéristiques de performance pour tubes, raccords et leurs assemblages

Le présent document spécifie les exigences de performance pour les tubes, raccords et leurs assemblages en plastique sans pression destinés :
-   aux applications pour eaux-vannes et eaux usées a l'intérieur du bâtiment (marquées par " B ") ;
-   aux applications enterrées dans la structure du bâtiment (marquées par " BD ") de diametre supérieur ou égal a 75 mm,
et indique les méthodes associées pour la vérification et l'évaluation de la conformité au présent document.
NOTE   Pour cette application, la " résistance a l'écrasement ", la " résistance a la pression interne et externe ", la " résistance a la flexion longitudinale ", la " résistance a la température élevée (pour réseaux de chauffage) ", la " résistance au choc ", la " soudabilité (pour réseaux de gaz) ", la " résistance a la pénétration (pour réseaux de gaz) ", le " comportement électrostatique (pour réseaux de fioul) ", la " perméabilité ", les " propriétés thermiques " et l'" isolation thermique (associée a l'économie d'énergie) " ne sont pas traitées.

Cevni sistemi iz polimernih materialov - Odvodni sistemi v zgradbah - Lastnosti cevi, fitingov in njihovih spojev

General Information

Status
Withdrawn
Publication Date
26-Nov-2007
Withdrawal Date
31-Aug-2020
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
25-Aug-2020
Due Date
17-Sep-2020
Completion Date
01-Sep-2020

Relations

Buy Standard

Standard
EN 15012:2008
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Plastics piping systems - Soil and waste discharge systems within the building structure - Performance characteristics for pipes, fittings and their jointsCevni sistemi iz polimernih materialov -
Odvodni sistemi v zgradbah - Lastnosti cevi, fitingov in njihovih spojevSystemes de canalisations en plastique - Systemes pour l'évacuation des eaux-vannes et des eaux usées a l'intérieur de la structure des bâtiments - Caractéristiques de performance pour tubes, raccords et leurs assemblagesKunststoff-Rohrleitungssysteme - Rohrleitungssysteme zum Ableiten von Abwasser innerhalb der Gebäudestruktur - Eigenschaften für die Gebrauchstauglichkeit von Rohren, Formstücken und deren VerbindungenTa slovenski standard je istoveten z:EN 15012:2007SIST EN 15012:2008en,fr,de91.140.80Drenažni sistemiDrainage systems23.040.45Fitingi iz polimernih materialovPlastics fittings23.040.20Cevi iz polimernih materialovPlastics pipesICS:SLOVENSKI
STANDARDSIST EN 15012:200801-januar-2008







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15012October 2007ICS 23.040.01; 91.140.80 English VersionPlastics piping systems - Soil and waste discharge systemswithin the building structure - Performance characteristics forpipes, fittings and their jointsSystèmes de canalisations en plastique - Systèmes pourl'évacuation des eaux-vannes et des eaux usées àl'intérieur de la structure des bâtiments - Caractéristiquesde performance pour tubes, raccords et leurs assemblagesKunststoff-Rohrleitungssysteme - Rohrleitungssystemezum Ableiten von Abwasser innerhalb der Gebäudestruktur- Eigenschaften für die Gebrauchstauglichkeit von Rohren,Formstücken und deren VerbindungenThis European Standard was approved by CEN on 23 August 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2007 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15012:2007: E



EN 15012:2007 (E) 2 Contents Page Foreword 3 Introduction 4 1 Scope 5 2 Normative references 5 3 Terms, definitions and symbols 6 4 Performance requirements 6 4.1 Reaction to fire for applications inside building 6 4.2 Dimensional tolerances 6 4.3 Tightness (air and liquid) 6 4.4 Durability 7 4.5 Maximum load for admissible deformation for pipes and fittings for applications buried in ground within the building structure 7 4.6 Dangerous substances 8 5 Test methods 8 5.1 Reaction to fire for applications inside building 8 5.2 Dimensional tolerances 8 5.3 Tightness 8 5.4 Durability 8 5.5 Ring stiffness for applications buried in ground within the building structure 8 6 Evaluation of conformity 8 6.1 General 8 6.2 Initial type testing 9 6.3 Factory production control 10 6.4 One-off products and products produced in very low quantities 13 Annex A (normative)
Mounting and fixing of components in the test apparatus
according to
EN 13823 14 Annex B (normative)
Product standards for soil and waste discharge piping systems in plastics materials 16 Annex C (normative)
Standards for assessment of conformity for soil and waste discharge piping systems in plastics materials 17 Annex ZA (informative)
Clauses of this European Standard addressing the provisions of
the EU Construction Products Directive 18 ZA.1 Scope and relevant characteristics 18 ZA.2 Procedure for attestation of conformity of plastics pipes and fittings 20 ZA.3 CE marking and labelling 23 Bibliography 27



EN 15012:2007 (E) 3 Foreword This document (EN 15012:2007) has been prepared by Technical Committee CEN/TC 155 “Plastics piping systems and ducting systems”, the secretariat of which is held by NEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2008, and conflicting national standards shall be withdrawn at the latest by July 2009. This document has been prepared under Mandate M/131 "Pipes, tanks and ancillaries not in contact with water intended for human consumption" given to CEN by the European Commission and the European Free Trade Association and supports essential requirements of EU Directives. For the relationship with EU Directives, see informative Annex ZA, which is an integral part of this document. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.



EN 15012:2007 (E) 4 Introduction This document contains only the performance characteristics needed to meet the essential requirements of EU Directive(s). It does not cover all characteristics of the products. These are specified in the standards listed in Annex B or in other appropriate product specifications. This harmonised document is part of a family of cluster standards addressing plastics piping systems. The relationship is shown below:
Material independent
Specific solutions
Figure 1



EN 15012:2007 (E) 5 1 Scope This document specifies performance requirements for non-pressure plastics pipes, fittings and their joints intended for soil and waste applications:  inside the building (application area code "B"),  buried in ground within the building structure (application area code "BD") and with a diameter greater than or equal to 75 mm, and gives associated test methods for verification and evaluation of conformity with this document. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 681-1,
Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 1: Vulcanised rubber EN 681-2,
Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 2: Thermoplastic elastomers EN 681-3,
Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 3: Cellular materials of vulcanised rubber EN 681-4,
Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 4: Cast polyurethane sealing elements EN 1053,
Plastics piping systems — Thermoplastics piping systems for non-pressure applications — Test method for watertightness EN 1054,
Plastics piping systems — Thermoplastics piping systems for soil and waste discharge — Test method for airtightness of joints EN 1055,
Plastics piping systems — Thermoplastics piping systems for soil and waste discharge inside buildings — Test method for resistance to elevated temperature cycling EN 13501-1,
Fire classification of construction products and building elements — Part 1: Classification using test data from reaction to fire tests EN 13823,
Reaction to fire tests for building products — Building products excluding floorings exposed to the thermal attack by a single burning item EN ISO 3126,
Plastics piping systems — Plastics components — Determination of dimensions (ISO 3126:2005) EN ISO 9001:2000, Quality management systems — Requirements (ISO 9001:2000) EN ISO 9969, Thermoplastics pipes — Determination of ring stiffness (ISO 9969:1994) ISO 13966, Thermoplastics pipes and fittings — Nominal ring stiffnesses ISO 13967,
Thermoplastics fittings — Determination of ring stiffness



EN 15012:2007 (E) 6 3 Terms, definitions and symbols For the purposes of this document, the following terms, definitions and symbols apply. 3.1 nominal size (DN) numerical designation of the size of a component, other than a component designated by thread size, which is a convenient round number approximately equal to the manufacturing dimension, in millimetres (mm) NOTE This can apply to either the internal diameter (DN/ID) or external diameter (DN/OD) 3.2 nominal outside diameter dn specified outside diameter, in millimetres, assigned to a nominal size DN 3.3 nominal ring stiffness SN numerical designation of the ring stiffness of a pipe or fitting, which is a convenient round number indicating the minimum required ring stiffness of the pipe or fitting NOTE
It is designated by the letters "SN" followed by the appropriate number. 4 Performance requirements 4.1 Reaction to fire for applications inside building Products conforming to this document shall be classified according to 5.1. 4.2 Dimensional tolerances The manufacturer shall declare the dimensional tolerances for the jointing of the components either by means of: a) reference to an appropriate European product standard given in Annex B, or b) in the absence of a European Standard, reference to a specific European product specification published by a recognized European organization, or c) in the absence of a) and b) reference to an International Standard, or
d) in the absence of a), b), and c), by stating the values of his own specification and associated jointing method. Dimensions shall be measured in accordance with 5.2 and shall be within the declared tolerances. 4.3 Tightness (air and liquid) 4.3.1 Tightness of elastomeric sealing ring joints The tightness of the jointed system shall be tested in accordance with 5.3 for sealing ring joints and the following shall apply:  no water leakage shall occur;  no air leakage shall occur.



EN 15012:2007 (E) 7 4.3.2 Tightness of joints made by using adhesive bonding or fusion techniques Jointing systems using adhesive bonding or fusion techniques shall be deemed to be tight provided the jointing work is executed in accordance with the manufacturer's instructions. Such instructions shall be made available by the manufacturer. 4.4 Durability 4.4.1 Durability of pipes and fittings The durability of the piping components shall be addressed as the resistance to elevated temperature cycling. The resistance to elevated temperature cycling shall be tested in accordance with 5.4. The piping system shall not show any leakage before and after the test. The sagging shall not exceed the following values:  DN ≤ 50:
≤ 3 mm;  DN > 50:
0,05 × dn mm. 4.4.2 Durability of elastomeric sealing joints The tightness of elastomeric sealing joints shall be deemed to be durable if the sealing element conforms to
EN 681-1, EN 681-2, EN 681-3 or EN 681-4, as applicable. 4.5 Maximum load for admissible deformation for pipes and fittings for applications buried in ground within the building structure 4.5.1 General For the intended end use buried in ground within the building structure, the maximum load for admissible deformation shall be addressed as ring stiffness. Ring stiffness shall be determined either by calculation or as described in 4.5.2 and 4.5.3. 4.5.2 Ring stiffness of pipes The ring stiffness of a thermoplastics pipe shall be determined in accordance with 5.5.1 and shall be expressed either as SN 2, SN 4, SN 8 or SN 16 following ISO 13966, as applicable, or as the actual value obtained in the test, expressed in kN/m2. 4.5.3 Stiffness of fittings The stiffness of a fitting made from the same material and having the same wall thickness and design as a corresponding pipe shall because of its geometry be deemed to have at least the same as the stiffness as that pipe. For other constructions the ring stiffness of bends and branches with the largest side branch shall be measured in accordance with 5.5.2. Based on the obtained lowest value of the result other fittings of the same design family can be classified with the same stiffness class. The ring stiffness of a thermoplastics fitting shall be expressed either as SN 2, SN 4, SN 8 or SN 16 following ISO 13966, as applicable, or as the actual value obtained in the test, expressed in kN/m2. The fittings manufacturer shall declare for which pipe stiffness classes the product is suitable. NOTE This clause is only applicable for components intended to be used buried in ground within the building structure and with a nominal outside diameter greater than or equal to 75 mm.



EN 15012:2007 (E) 8 4.6 Dangerous substances Attention is drawn to NOTE 1 and NOTE 2 in ZA.1. NOTE Mandate M/366 “Development of horizontal standardised assessment methods for harmonised approach relating to dangerous substances under the Construction Products Directive (CPD)“ as issued by the European Commission, will require specifications relating to dangerous substances once applicable to the covered products. 5 Test methods 5.1 Reaction to fire for applications inside building Classification shall be in accordance with EN 13501-1. Mounting and fixing of pipes shall conform to Annex A. If no pipes are available, testing of fittings may be done in form of a linear assembly, e.g. couplers. NOTE In case where e.g. the given dimensions do not exist the choice of dimensions and the mounting and fixing should be agreed between the manufacturer and the notified body. 5.2 Dimensional tolerances The dimensions shall be measured in accordance with EN ISO 3126. 5.3 Tightness The piping system shall be tested according to EN 1053 and EN 1054, whereby the sampling procedure is free and the number of test pieces is one (see 6.1). 5.4 Durability The piping system shall be tested according to EN 1055. 5.5 Ring stiffness for applications buried in ground within the building structure 5.5.1 Ring stiffness of thermoplastics pipes For thermoplastics pipes the ring stiffness shall be determined in accordance with EN ISO 9969. 5.5.2 Stiffness of thermoplastics fittings For thermoplastics fittings with structured wall the ring stiffness of bends and branches shall be determined in accordance with ISO 13967. 6 Evaluation of conformity 6.1 General The conformity of pipes and fittings with the requirements of this European Standard and with the declared values (including classes) shall be demonstrated by:  initial type testing;



EN 15012:2007 (E) 9  factory production control by the manufacturer, including product assessment. For the purposes of testing, pipes and fittings may be grouped into families, where it is considered that the results for one or more characteristics from any product within the family are representative for the same characteristics for all products within that family. NOTE A product can be in more than one family for different characteristics. For type testing the following family groups apply: a) Size groups for pipes and fittings as given in Table 1. Table 1 — Size groups Size group Range of nominal diameters, dn 1 32 < dn ≤ 63 2 63 < dn ≤ 180 3 dn > 180
b) Type groups for thermoplastics piping components as given in Table 2. Table 2 — Type groups Type group Thermoplastics piping components 1 Bends 2 Branches 3 Other fittings
6.2 Initial type testing 6.2.1 General Relevant type tests shall be carried out on new products and whenever there is a change in design, in material and/or in production method, other than routine in-process adjustment and extension of the product range (see Table 3). A change of supplier of a material or stabiliser does not lead to a change in performance if the chemical composition remains the same. Material modifications within certain limits are not considered as a change of material. Guidance for these limits can be found in the documents given in Annex C. For tests previously performed in accordance with the provisions of the standards listed in Annex B, or the recognized European specification, as applicable, (same product, same characteristic(s), same test method, same system of attestation etc.) the results may be taken into account. All characteristics given in Clause 4 shall be subject to calculation and/or initial type testing, except 4.4.2 where the characteristics of the components used have already been determined by the component manufacturer on the basis of conformity with other product standards. However this does not relieve the manufacturer of the piping system from the responsibility of ensuring that the system conforms to the requirements of this document.



EN 15012:2007 (E) 10 6.2.2 Initial type test requirements The initial type testing of the characteristics according to Clause 4 shall be performed in accordance with the sampling procedure given under type tests (TT) of the applicable product specific standards for assessment of conformity as given in Annex C. If the standard does not contain one or more of the characteristics, then testing as given in Table 3 shall apply. For products where no such standard exists Table 3 shall apply. Table 3 — Type testing of pipes and fittings Testing relevant to a Essential characteristics Requirement clause of this document I M E Sampling procedure (minimum sampling) Acceptance Reaction to fire 4.1 + b + b — Once/compound or formulation c See classification in EN 13501-1 Dimensional tolerances 4.2 + + + Once/size/fitting/ compound or formulation Pass/fail Tightness of joints 4.3 + — + d One diameter/size group/joint design Pass/fail Durability 4.4 + + + Once/compound or formulation Pass/fail Maximum load for admissible deformation e – pipes
– fittings 4.5
+
+
+
+
+
+
One pipe sample/size group/SN class for each material
Once/size/fitting group 1 (largest angle of bend of the size) and 2 (45° branch) Pass/fail a I is initial type test in case of new system
M is change of material
E is extension of the product range with new size group or fitting group.
+ denotes testing relevant for the characteristic-occurrence-combination. b Only obligatory if subject to regulatory requirements applicable in the place of use (see also Table ZA.3). c In case of single burning item (SBI) test the vertical part shall be size 110 and the horizontal part size 40, which will then be representative for all dimensions. In case where the given dimensions do not exist the choice of dimensions and the mounting and fixing should be agreed between the manufacturer and the notified body. d
Only in case of dimension extension. e
Only for components intended to be used buried in ground within the building structure and with a nominal outside diameter equal or greater than 75 mm.
Test reports shall be kept by the manufacturer for at least 10 years after discontinuation of the product. 6.3 Factory production control 6.3.1 General The manufacturer shall establish, document and maintain an FPC system to ensure that the products placed on the market conform to the stated performance characteristics. The FPC system shall consist of procedures, regular inspections and tests and/or assessments and the use of the results to control raw and other incoming materials or components, equipment, the production process and the product.



EN 15012:2007 (E) 11 If the manufacturer has the component designed, manufactured, assembled, packed, processed and labelled by subcontracting, FPC of the original manufacturer may be taken into account. However, where subcontracting takes place, the manufacturer shall retain the overall control of the component and ensure that he receives all the information that is necessary to fulfil his responsibilities according to this European Standard. The manufacturer who subcontracts all of his activities may in no circumstances discharge himself of his responsibilities to a subcontractor. All the elements, requirements and provisions adopted by the manufacturer shall be documented in a systematic manner in the form of written policies and procedures. This production control system documentation shall ensure a common understanding of conformity evaluation and enable the achievement of the required component characteristics and the effective operation of the production control system to be checked. Factory production control therefore brings together operational techniques and all measures allowing maintenance and control of the conformity of the component with its technical specifications. Its implementation may be achieved by controls and tests on raw materials and constituents, processes, manufacturing equipment and finished components, including material properties in components, and by making use of the results thus obtained. The results of inspections, tests or assessments requiring action shall be recorded, as shall any action taken. The action to be taken when control values or criteria are not met shall be recorded and retained for the period specified in the manufacturers FPC procedures. The specifications of all incoming raw materials and components shall be documented, and the inspection scheme for ensuring their conformity shall be established. Manufacturers operating a quality system, which conforms to or is no less stringent than the relevant requirements of EN ISO 9001:2000 and which is made specific to products covered by this European Standard shall be deemed to satisfy the FPC requirements of this European Standard. 6.3.2 FPC requirements The FPC of the characteristics according to Clause 4 shall be performed in accordance with the sampling procedure given under batch release tests (BRT) of the applicable product specific standards for assessment of conformity as given in Annex C. If the standard does not contain one or more of the characteristics, then testing as given in Table 4 shall apply. For products where no such standard exists Table 4 shall apply.



EN 15012:2007 (E) 12 Table 4 — Factory production control of pipes and fittings Essential characteristics Requirement clause of this European Standard Test method Sampling procedure (minimum sampling) Acceptance Reaction to fire a 4.1 Identification of compound or formulation Once/batch See classification in EN 13501-1 Dimensional tolerances 4.2 EN ISO 3126 or accor-ding to the manufac-turer's quality plan Once/batch Pass/fail Tightness of joints 4.3 Indirect testing: see dimensional tolerances Once/batch Pass/fail Durability 4.4 Indirect testing: see 4.4.1 and check of compound or formulation Once/batch Pass/fail a Only obligatory if subject to regulatory requirements applicable in the place of use.
6.3.3 FPC system requirements 6.3.3.1 Personnel The responsibility, authority and the relationship between personnel that manages, performs or verifies work affecting product conformity, shall be defined. This applies in particular to personnel that need to initiate actions preventing product non-conformities from occurring, actions in case of non-conformities and to identify and register product conformity problems. Personnel performing work affecting product conformity shall be competent on the basis of appropriate education, training, skills and experience for which records shall be maintained. 6.3.3.2 Equipment All weighing, measuring and testing equipment necessary to achieve, or produce evidence of, conformity shall be calibrated or verified and regularly inspected according to documented procedures, frequencies and criteria. Control of monitoring and measuring devices shall comply with the appropriate clause of EN ISO 9001:2000. All equipment used in the manufacturing process shall be regularly inspected and maintained to ensure use, wear or failure does not cause inconsistency in the manufacturing process. Inspections and maintenance shall be carried out and recorded in accordance with the manufacturer’s written procedures and the records retained for the period defined in the manufacturer's FPC procedures. 6.3.3.3 Raw materials and components The specifications of all incoming raw materials and components shall be documented, as shall the inspection scheme for ensuring their conformity. The verification of conformity of the raw material with the specification shall be in accordance with EN ISO 9001:2000, 7.4.3.



EN 15012:2007 (E) 13 6.3.3.4 In-process control The manufacturer shall plan and carry out production under controlled conditions. Compliance with EN ISO 9001:2000, 7.5.1 and 7.5.2 shall be deemed to satisfy the requirements of this subclause. 6.3.3.5 Traceability and marking Individual products and product batches shall be identifiable and traceable with regard to their production origin. The manufacturer shall have written procedures ensuring that processes related to affixing traceability codes and/or markings (see ZA.3) are inspected regularly. Compliance with EN ISO 9001:2000, 7.5.3 shall be deemed to satisfy the requirements of this subclause. 6.3.3.6 Non-conforming products The manufacturer shall have written procedures which specify how non-conforming products shall be dealt with. Any such events shall be recorded as they occur and these records shall be kept for the period defined in the manufacturer’s written procedures. Compliance with EN ISO 9001:2000, 8.3 shall be deemed to satisfy the requirements of this subclause. 6.3.3.7 Corrective action The manufacturer shall have documented procedures that instigate action to eliminate the cause of non-conformities in order to prevent recurrence. Compliance with EN ISO 9001:2000, 8.5.2 shall be deemed to satisfy the requirements of this subclause. 6.3.3.8 Handling, storage and packaging The manufacturer shall have procedures providing methods of product handling and shall provide suitable storage areas preventing damage or deterioration. 6.4 One-off products and products produced in very low quantities Products produced as a one-off and products produced in very low quantities (less than 20 per year) are assessed as follows. For initial type assessment, the provisions of Table 3 apply, with the following exception:  for reaction to fire the classification of other products made out of the same compound or formulation may be used. The FPC system of one-off products and products produced in very low quantities shall ensure that raw materials and/or components are sufficient for the product; the provisions of Table 4 applying only where appropriate. The manufacturer shall maintain records allowing traceability of the product.



EN 15012:2007 (E) 14 Annex A (normative)
Mounting and fixing of components in the test apparatus
according to EN 13823 Dimensions in millimetres
Key 1 metallic bracket under socket Figure A.1 — Mounting and fixing of components



EN 15012:2007 (E) 15 Dimensions in millimetres
Figure A.2 — Details of mounting and fixing of components



EN 15012:2007 (E) 16 Annex B (normative)
Product standards for soil and waste discharge piping systems in plastics materials EN 1329-1,
Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 1: Specifications for pipes, fittings and the system EN 1451-1,
Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure — Polypropylene (PP) — Part 1: Specifications for pipes, fittings and the system EN 1453-1,
Plastics piping systems with structured wall-pipes for soil and waste discharge (low and high temperature) inside buildings — Unplasticized poly(vinyl chloride) (PVC-U) — Part 1: Specifications for pipes and the system EN 1455-1,
Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure — Acrylonitrile-butadiene-styrene (ABS) — Part 1: Requirements for pipes, fittings and the system EN 1519-1,
Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure — Polyethylene (PE) — Part 1: Specifications for pipes, fittings and the system EN 1565-1,
Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure — Styrene copolymer blends (SAN+PVC) — Part 1: Specifications for pipes, fittings and the system EN 1566-1,
Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure — Chlorinated poly(vinyl chloride) (PVC-C) — Part 1: Specifications for pipes, fittings and the system NOTE This list represents the situation at the time this document was published. At the next revision, it can be amended once new standards are developed.



EN 15012:2007 (E) 17 Annex C (normative)
Standards for assessment of conformity for soil and waste discharge piping systems in plastics materials This annex is normative as far as the assessment of conformity information contained in the listed standards and referred to in Clause 6 for the essential characteristics is concerned. Otherwise it has the status of an informative annex. ENV 1329-2:2001,
Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 2: Guidance for the assessment of conf
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.