Abstract

In this document, the pozzolanicity of a cement is assessed by comparing the concentration of calcium ion, expressed as calcium oxide, present in the aqueous solution in contact with the hydrated cement, after a fixed period of time, with the quantity of calcium ion capable of saturating a solution of the same alkalinity.

Status
Not Published
Publication Date
21-Aug-2028
Current Stage
4020 - Submission to enquiry - Enquiry
Start Date
03-Sep-2026
Due Date
11-May-2027
Completion Date
11-May-2027

Buy Documents

prEN 196-5 is a CEN draft European Standard for testing the pozzolanicity of pozzolanic cement. It specifies a reference laboratory method that compares calcium ion, expressed as calcium oxide, in solution with the calcium concentration needed to saturate a solution of the same alkalinity.

The document is for laboratories, manufacturers, and quality teams that need a common pass/fail test for pozzolanic cement according to EN 197-1.

What does prEN 196-5 specify?

prEN 196-5 specifies the method for measuring the pozzolanicity of pozzolanic cements according to EN 197-1. It is the reference procedure for this test and it does not apply to Portland pozzolana cements or to pozzolanas.

The document is organized into clauses 1 to 12, covering scope, references, terms, principle, test rules, sample preparation, reagents, apparatus, solution standardization, procedure, results, and reporting.

What are the key requirements of prEN 196-5?

Test basis and acceptance

Clause 4 states that pozzolanicity is judged by comparing the calcium ion concentration in the aqueous phase after a fixed time with the saturation concentration at the same alkalinity. A cement passes when the measured calcium concentration is below the saturation curve, so the result is a laboratory comparison rather than a direct strength or composition test.

Clause 4 also notes that a 20 g cement and 100 ml water mixture at 40 °C typically reaches equilibrium between 8 d and 15 d. If the cement already passes at 8 d, the test does not need to continue to 15 d.

Sampling, test count, and precision handling

Clause 5 sets the minimum number of tests. One test is enough when the determination is part of a statistically controlled series, but two tests are required otherwise and also in case of dispute. This matters because it sets when a single result is acceptable and when averaging is required.

Clause 5 also defines repeatability and reproducibility for this document, and it gives the reporting precision for masses, volumes, and solution factors. Clause 11 later uses repeatability to decide when two results are too far apart and the test must be repeated.

Sample preparation, reagents, and apparatus

Clause 6 requires a homogeneous cement test sample prepared from the laboratory sample taken according to EN 196-7. The sample is sieved, any retained material is ground to pass the sieve, and the prepared sample is stored airtight and handled quickly to limit exposure to ambient air.

Clauses 7 and 8 set the reagent quality and apparatus needed for the method. The procedure uses analytical-grade reagents, low-conductivity water, a thermostatically controlled enclosure at 40 ± 1 °C, a pH meter, a balance, burettes, pipettes, and an absorbance measuring setup at 520 nm or 620 nm for one of the end-point options.

Solution standardization and measurement steps

Clause 9 standardizes the EDTA (ethylenediaminetetra-acetic acid) solution using calcium carbonate, and standardizes the 0.1 mol/l hydrochloric acid solution using sodium carbonate. The EDTA end point may be found photometrically or visually, and this affects how the titration is read in practice.

Clause 10 describes the core test: the cement is stored with freshly decarbonized water in a sealed polyethylene container, kept at 40 °C, then filtered after 8 d or 15 d. The filtrate is titrated first for hydroxyl ion concentration and then for calcium oxide concentration, so the laboratory gets the two values needed for the final assessment.

Result calculation and reporting

Clause 11 requires results to be calculated and expressed to the nearest 0.1 mmol/l. The measured point is plotted against the saturation curve in Figure 1, and the cement passes when the point lies below that curve.

Clause 12 requires all individual results to be recorded and the final report to state whether the cement satisfies or does not satisfy the test for pozzolanicity according to EN 196-5.

What terms does prEN 196-5 use?

  • Pozzolanicity - the property assessed by comparing dissolved calcium in the test solution with the calcium level needed for saturation at the same alkalinity.
  • Pozzolanic cement - the cement product category covered by the method, as identified in EN 197-1.
  • Hydroxyl ion - the alkalinity value measured in the filtrate and used together with calcium oxide in the final plot.
  • Calcium ion expressed as calcium oxide - the calcium result format used throughout the method for comparison and reporting.
  • Repeatability - agreement of results obtained under the same laboratory conditions with the same method, operator, equipment, and short time interval.
  • Reproducibility - agreement of results obtained in different laboratories with different operators and equipment.
  • EDTA - the titrant used to determine calcium in the filtrate after the solution has been adjusted to the required pH.

Who uses prEN 196-5?

prEN 196-5 is used by cement testing laboratories, cement producers, and quality control staff who need to verify pozzolanicity against a common reference method. It is also relevant to conformity assessment and dispute testing, because the standard sets the test count, precision handling, and reporting format.

What changed in prEN 196-5 from the previous edition?

prEN 196-5:2026 will supersede EN 196-5:2011. The significant technical changes stated for this draft are:

  • redefinition of the introduction
  • introduction of the Calconcarbonic acid indicator
  • modification of the EDTA standardization section to include visual determination of the end point
  • modification of the storage and filtration section
  • modification of the repeatability data in the calcium determination section

Which standards are used with prEN 196-5?

StandardWhat it contributes
EN 196-7Sampling and sample preparation of common cement and its constituents
EN ISO 385Requirements for burettes used in the titrations
EN ISO 835Requirements for graduated pipettes used in the procedure
EN 197-1The cement classification used to identify the pozzolanic cements covered by this method

What does the prEN 196-5 document contain?

The document contains the test principle, laboratory preparation steps, reagent recipes, apparatus requirements, and two solution-standardization procedures. It also includes the storage, filtration, titration, calculation, and pass/fail assessment steps needed to carry out the test.

It provides a saturation curve in Figure 1 for judging the result, plus formulas for solution factors and for calculating hydroxyl ion and calcium oxide concentrations. The reporting clause tells the user what to record and how to state the final conclusion.

Relations

Effective Date
24-Jun-2026

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

prEN 196-5 is a draft published by the European Committee for Standardization (CEN). Its full title is "Methods of testing cement - Part 5: Pozzolanicity test for pozzolanic cement". This standard covers: In this document, the pozzolanicity of a cement is assessed by comparing the concentration of calcium ion, expressed as calcium oxide, present in the aqueous solution in contact with the hydrated cement, after a fixed period of time, with the quantity of calcium ion capable of saturating a solution of the same alkalinity.

In this document, the pozzolanicity of a cement is assessed by comparing the concentration of calcium ion, expressed as calcium oxide, present in the aqueous solution in contact with the hydrated cement, after a fixed period of time, with the quantity of calcium ion capable of saturating a solution of the same alkalinity.

prEN 196-5 is classified under the following ICS (International Classification for Standards) categories: 91.100.10 - Cement. Gypsum. Lime. Mortar. The ICS classification helps identify the subject area and facilitates finding related standards.

prEN 196-5 has the following relationships with other standards: It is inter standard links to EN 196-5:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

prEN 196-5 is associated with the following European legislation: EU Directives/Regulations: 305/2011. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

prEN 196-5 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Principle
  • 5 General requirements for testing
  • 5.1 Number of tests
  • 5.2 Repeatability and reproducibility
  • 5.3 Expression of masses, volumes and factors
  • 5.4 Determination of constant mass
  • 6 Preparation of a test sample of cement
  • 7 Reagents
  • 7.1 General
  • 8 Apparatus
  • 8.2 Wide stem funnel
  • 8.13 Apparatus for measuring the absorbance, at 520 nm and 620 nm of a solution contained
  • 8.16 Temperature recorder - for checking the temperatures inside the uniform temperature
  • 8.17 Chronometer/Timer
  • 9 Standardization of solutions
  • 9.1 Standardization of the EDTA solution
  • 9.2 Standardization of the 0,1 mol/l solution of hydrochloric acid
  • 10 Procedure
  • 10.1 Storage and filtration
  • 10.2 Determination of the hydroxyl ion concentration
  • 10.3 Determination of the calcium oxide concentration
  • 11 Results
  • 11.1 Calculation and expression of results
  • 11.2 Assessment of pozzolanicity
  • 1 Pass
  • 2 Fail
  • 11.3 Repeatability and reproducibility
  • 12 Reporting of results
  • Bibliography

Introduction

In this document, the pozzolanicity of a cement is assessed by comparing the concentration of calcium ion, expressed as calcium oxide, present in the aqueous solution in contact with the hydrated cement, after a fixed period of time, with the quantity of calcium ion capable of saturating a solution of the same alkalinity.

oSIST prEN 196-5:2026 prEN 196-5:2005 (E)

1 Scope

This document specifies the method of measuring the pozzolanicity of pozzolanic cements according to EN 197-1. This document does not apply to Portland pozzolana cements or to pozzolanas.

This method constitutes the reference procedure.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

EN 196-7, Methods of testing cement — Methods for sampling and sample preparation of common cement and its constituents EN ISO 385, Laboratory glassware — Burettes EN ISO 835, Laboratory glassware — Graduated pipettes

3 Terms and definitions

No terms and definitions are listed in this document.

4 Principle

The pozzolanicity is assessed by comparing the concentration of calcium ion, expressed as calcium oxide, present in the aqueous solution in contact with the hydrated cement, after a fixed period of time, with the quantity of calcium ion capable of saturating a solution of the same alkalinity. The cement is considered to satisfy the test, i.e. gives a positive result, if the concentration of calcium ion in the solution is lower than the saturation concentration. NOTE Experiment has shown that a mixture of 20 g of cement and 100 ml of water at 40 °C achieves equilibrium after a period of between 8 d and 15 d. If the cement satisfies the test at 8 d (see 11.2) it is not necessary to continue to 15 d.

5 General requirements for testing

5.1 Number of tests

Where the determination is one of a series subject to statistical control, determination by a single test shall be the minimum required.

Where the determination is not part of a series subject to statistical control, the number of tests shall be two (see also 11.1) In the case of dispute, the number of tests shall be two.

oSIST prEN 196-5:2026 prEN 196-5:2026 (E)

5.2 Repeatability and reproducibility

Repeatability - Precision under repeatability conditions where independent test results are obtained with the same method on identical test items (material) in the same laboratory by the same operator using the same equipment within short intervals of time. Reproducibility - Precision under reproducibility conditions where test results are obtained with the same method on identical test items (material) in different laboratories with different operators using different equipment.

Repeatability and reproducibility in this document are expressed as repeatability standard deviation(s) and reproducibility standard deviation(s).

5.3 Expression of masses, volumes and factors

Express masses in grams to the nearest 0,000 1 g and volumes from the burette in millilitres to the nearest 0,05 ml. Express the factors of solutions, given by the mean of three determinations, to three decimal places.

5.4 Determination of constant mass

Determine constant mass by drying for successive periods at the stated temperature, or making successive 15 min ignitions, followed each time by cooling and then weighing. Constant mass is reached when the difference between two successive weightings is less than 0,000 5 g.

6 Preparation of a test sample of cement

Before starting the determinations, treat the laboratory sample, taken in accordance with EN 196-7, as follows to obtain a homogenous test sample.

Take approximately 100 g of the sample using a sample divider or by quartering. Sieve this portion on a 150 µm or 125 µm sieve until the residue remains constant. Grind the retained material so that it completely passes the 150 µm or 125 µm sieve. Transfer the sample to a clean dry container with an airtight closure and shake vigorously to mix it thoroughly Carry out all operations as quickly as possible to ensure that the sample is exposed to ambient air only for the minimum time

7 Reagents

7.1 General

Use only reagents of analytical quality. References to water mean distilled or de-ionized water having an electrical conductivity ≤ 0,5 mS/m. The quantities of reagents listed are to indicate concentrations; actual quantities to be prepared shall be adjusted according to the amounts required. Attention to tolerances when weighing.

Unless otherwise stated (%) means percent by mass.

3 3 7.1.1 Concentrated hydrochloric acid (HCl), (ρ = 1,18 g/cm to 1,19 g/cm ).

7.1.2 Dilute hydrochloric acid, about 0,1 mol/l, prepared by adding 8,5 ml of concentrated

hydrochloric acid (7.1.1), measured using the 50 ml burette (8.8), to a 1 l volumetric flask (8.10) containing about 500 ml of water and making up to 1 000 ml with water Alternatively, it may be used a dilute hydrochloric acid 0,1 mol/l RPE-NORMEX for analysis

oSIST prEN 196-5:2026 prEN 196-5:2005 (E)

7.1.3 Dilute hydrochloric acid (1 + 2), prepared by adding 250 ml of concentrated

hydrochloric acid (7.1.1) to 500 ml water.

7.1.4 Methyl orange, (dimethylaminoazobenzene p-sodium sulfonate).

7.1.5 Methyl orange indicator, prepared by dissolving (0,020 ± 0,002) g of methyl orange

(7.1.4) in water and making up to 1 000 ml.

7.1.6 Sodium hydroxide, (NaOH).

7.1.7 Sodium hydroxide solution 2 mol/l - Dissolve (80 ± 1) g of sodium hydroxide in

distilled water and make up to 1000 ml (store in a polyethylene bottle).

7.1.8 Calcium carbonate, (CaCO ), dried to constant mass at (200 ± 10) °C (purity greater than

99,9 %).

7.1.9 Sodium chloride, (NaCl), dried to constant mass at (110 ± 5) °C. 7.1.1O Murexide, (ammonium purpurate).

7.1.11 Murexide indicator, prepared by grinding (1,0 ± 0,1) g of murexide with (100 ± 1) g of

dry sodium chloride (NaCl).

7.1.12 EDTA, (dihydrated disodium salt of ethylenediaminetetra-acetic acid).

...