EN ISO 16811:2014
(Main)Non-destructive testing - Ultrasonic testing - Sensitivity and range setting (ISO 16811:2012)
Non-destructive testing - Ultrasonic testing - Sensitivity and range setting (ISO 16811:2012)
ISO 16811:2012 specifies the general rules for setting the timebase range and sensitivity (i.e. gain adjustment) of a manually operated ultrasonic flaw detector with A-scan display in order that reproducible measurements may be made of the location and echo height of a reflector.
ISO 16811:2012 is applicable to techniques employing a single contact probe with either a single or twin transducers, but excludes the immersion technique and techniques employing more than one probe.
Zerstörungsfreie Prüfung - Ultraschallprüfung - Empfindlichkeits- und Entfernungsjustierung (ISO 16811:2012)
Essais non destructifs - Contrôle par ultrasons - Réglage de la sensibilité et de la base de temps (ISO 16811:2012)
L'ISO 16811:2012 spécifie les règles générales de réglage de l'échelle de la base de temps et de la sensibilité (c'est-à-dire la commande de gain) d'un détecteur de défaut ultrasonore à commande manuelle et à représentation de type A afin de pouvoir effectuer des mesurages reproductibles de la localisation et de la hauteur d'écho du réflecteur.
L'ISO 16811:2012 s'applique aux techniques qui utilisent un traducteur à contact simple avec transducteur unique ou à émetteur et récepteur séparés, mais exclut la technique en immersion et les techniques utilisant plus d'un traducteur.
Neporušitvene preiskave - Ultrazvočne preiskave - Občutljivost in območje nastavitve (ISO 16811:2012)
Standard EN ISO 16811 določa splošna pravila za nastavitev območja in občutljivosti (tj. nastavitev ojačanja) ročno upravljanega ultrazvočnega detektorja napak z A-scan prikazovalnikom z namenom, da se lahko opravi ponovljive meritve na podlagi lokacije in višine odboja. Standard velja tudi za tehnike, ki uporabljajo sondo z enojnim kontaktom z enim ali dvema pretvornikoma, ne velja pa za imerzno tehniko in tehnike, ki uporabljajo več kot eno sondo.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-2014
1DGRPHãþD
SIST EN 583-2:2001
1HSRUXãLWYHQHSUHLVNDYH8OWUD]YRþQHSUHLVNDYH2EþXWOMLYRVWLQREPRþMH
QDVWDYLWYH,62
Non-destructive testing - Ultrasonic testing - Sensitivity and range setting (ISO
16811:2012)
Zerstörungsfreie Prüfung - Ultraschallprüfung - Empfindlichkeits- und
Entfernungsjustierung (ISO 16811:2012)
Essais non destructifs - Contrôle par ultrasons - Réglage de la sensibilité et de la base
de temps (ISO16811:2012)
Ta slovenski standard je istoveten z: EN ISO 16811:2014
ICS:
19.100 Neporušitveno preskušanje Non-destructive testing
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN ISO 16811
NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2014
ICS 19.100 Supersedes EN 583-2:2001
English Version
Non-destructive testing - Ultrasonic testing - Sensitivity and
range setting (ISO 16811:2012)
Essais non destructifs - Contrôle par ultrasons - Réglage de Zerstörungsfreie Prüfung - Ultraschallprüfung -
la sensibilité et de la base de temps (ISO 16811:2012) Empfindlichkeits- und Entfernungsjustierung (ISO
16811:2012)
This European Standard was approved by CEN on 9 February 2014.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 16811:2014 E
worldwide for CEN national Members.
Contents Page
Foreword .3
Foreword
The text of ISO 16811:2012 has been prepared by Technical Committee ISO/TC 135 “Non-destructive testing”
of the International Organization for Standardization (ISO) and has been taken over as EN ISO 16811:2014 by
Technical Committee CEN/TC 138 “Non-destructive testing” the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by September 2014, and conflicting national standards shall be
withdrawn at the latest by September 2014.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 583-2:2001.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Endorsement notice
The text of ISO 16811:2012 has been approved by CEN as EN ISO 16811:2014 without any modification.
INTERNATIONAL ISO
STANDARD 16811
First edition
2012-04-01
Non-destructive testing — Ultrasonic
testing — Sensitivity and range setting
Essais non destructifs — Contrôle par ultrasons — Réglage de la
sensibilité et de la base de temps
Reference number
ISO 16811:2012(E)
©
ISO 2012
ISO 16811:2012(E)
© ISO 2012
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2012 – All rights reserved
ISO 16811:2012(E)
Contents Page
Foreword .v
Introduction .vi
1 Scope.1
2 Normative references.1
3 General.1
3.1 Quantities and symbols.1
3.2 Test objects, reference blocks and reference reflectors.1
3.3 Categories of test objects.1
3.4 Contouring of probes.2
3.4.1 Longitudinally curved probes .3
3.4.2 Transversely curved probes.3
3.4.3 Concave scanning surface.4
4 Determination of probe index and beam angle .4
4.1 General.4
4.2 Flat probes.4
4.2.1 Calibration block technique .4
4.2.2 Reference block technique.4
4.3 Probes curved longitudinally .4
4.3.1 Mechanical determination.4
4.3.2 Reference Block Technique .6
4.4 Probes curved transversely .6
4.4.1 Mechanical determination.6
4.4.2 Reference block technique.7
4.5 Probes curved in two directions.8
4.6 Probes for use on materials other than non-alloy steel .9
5 Time base setting .9
5.1 General.9
5.2 Reference blocks and reference reflectors.9
5.3 Straight beam probes.10
5.3.1 Single reflector technique.10
5.3.2 Multiple reflector technique.10
5.4 Angle beam probes .10
5.4.1 Radius technique.10
5.4.2 Straight beam probe technique .10
5.4.3 Reference block technique.10
5.4.4 Contoured probes.10
5.5 Alternative range settings for angle beam probes .11
5.5.1 Flat surfaces.11
5.5.2 Curved surfaces.11
6 Sensitivity setting and echo height evaluation .13
6.1 General.13
6.2 Angle of impingement.13
6.3 Distance Amplitude Curve (DAC) technique .13
6.3.1 Reference blocks.13
6.3.2 Preparation of a Distance Amplitude Curve .14
6.3.3 Evaluation of signals using a Distance Amplitude Curve.15
6.3.4 Evaluation of signals using a reference height.15
6.4 Distance Gain Size (DGS) technique .16
6.4.1 General.16
6.4.2 Reference blocks.18
6.4.3 Use of DGS diagrams.18
6.4.4 Restrictions on use of the DGS technique due to geometry .20
ISO 16811:2012(E)
6.5 Transfer correction.20
6.5.1 General.20
6.5.2 Fixed path length technique .20
6.5.3 Comparative technique.21
6.5.4 Compensation for local variations in transfer correction .22
Annex A (normative) Quantities and symbols .23
Annex B (normative) Reference blocks and reference reflectors .26
Annex C (normative) Determination of sound path distance and impingement angle in
concentrically curved obj
...
Questions, Comments and Discussion