Aerospace series - Circuit breakers, single-pole, temperature compensated, rated currents 1 A to 25 A, switching capacity 65 /n/1000 A max. - Part 001: Technical specification

This standard specifies the required characteristics for single-pole, temperature compensated circuit breakers, rated currents from 1 A to 25 A, switching capacity 65 In/ 1000 A max., for use in aircraft electrical systems, at temperatures between - 55°C and 125°C and at a maximum altitude of Z = 22 000 m. It shall be used together with EN 2350. These circuit breakers are intended for use in aircraft with electrical supplies in accordance with EN 2282.

Luft- und Raumfahrt - Schutzschalter, einpolig, temperaturkompensiert, Nennströme von 1 A bis 25 A, Schaltvermögen 65 /n/1000 A max. - Teil 001: Technische Lieferbedingungen

Diese Norm legt die Anforderungen an temperaturkompensierte, einpolige, Schutzschalter mit Nennströmen von 1 A bis 25 A, Schaltvermögen 65 In/ 1000 A max., für den Einsatz in elektrischen Bordnetzen im Temperaturbereich zwischen - 55°C und 125°C bis zu einer maximalen Höhe von Z = 22 000 m fest. Sie ist in Verbindung mit EN 2350 anzuwenden. Diese Schutzschalter sind zum Einsatz in Luftfahrzeugen mit elektrischer Stromversorgung nach EN 2282 bestimmt.

Série aérospatiale - Disjoncteurs unipolaires compensés en température, intensités nominales 1 A à 25 A, pouvoir de coupure 65 /n/1000 A max. - Partie 001: Spécification technique

La présente norme spécifie les caractéristiques requises des disjoncteurs unipolaires compensés en température, d'intensités nominales 1 A à 25 A, pouvoir de coupure 65 In/ 1000 A max., utilisés dans les circuits électriques d'aéronefs, à des températures comprises entre - 55°C et 125°C et à une altitude maximale Z = 22 000 m. Elle doit être utilisée conjointement avec EN 2350. Ces disjoncteurs sont prévus pour être utilisés avec des alimentations électriques définies par EN 2282.

Aerospace series - Circuit breakers, single-pole, temperature compensated, rated currents 1 A to 25 A, switching capacity 65 /n/1000 A max. - Part 001: Technical specification

General Information

Status
Withdrawn
Publication Date
22-Jun-1999
Withdrawal Date
07-Oct-2014
Technical Committee
Drafting Committee
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
30-Jun-2017

Relations

Buy Standard

Standard
EN 3773-001:2002 - je enak SIST EN 3773-1:2001
English language
7 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Aerospace series - Circuit breakers, single-pole, temperature compensated, rated currents 1 A to 25 A, switching capacity 65 /n/1000 A max. - Part 001: Technical specificationLuft- und Raumfahrt - Schutzschalter, einpolig, temperaturkompensiert, Nennströme von 1 A bis 25 A, Schaltvermögen 65 /n/1000 A max. - Teil 001: Technische LieferbedingungenSérie aérospatiale - Disjoncteurs unipolaires compensés en température, intensités nominales 1 A a 25 A, pouvoir de coupure 65 /n/1000 A m
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.