Footwear - Test methods for uppers - Water resistance

This European Standard specifies a test method for determining the resistance of a footwear upper material to water penetration on flexing, in order to assess the suitability for the end use.

Schuhe - Prüfverfahren für Obermaterialien - Wasserbeständigkeit

Diese Europäische Norm legt ein Prüfverfahren zur Bestimmung der Beständigkeit eines Werkstoffs für Obermaterialien gegen das Durchdringen von Wasser beim Biegen fest, um die Gebrauchseigenschaften im fertigen Zustand zu bewerten.

Chaussures - Méthodes d'essai des tiges - Résistance à l'eau

Le présent projet de norme spécifie une méthode d'essai permettant de déterminer la résistance d'un matériau composant une tige de chaussure à la pénétration de l'eau à la flexion, afin d'évaluer s'il convient à l'utilisation finale.

Footwear - Test methods for uppers - Water resistance

General Information

Status
Withdrawn
Publication Date
11-Dec-2001
Withdrawal Date
16-Oct-2018
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
17-Oct-2018

Relations

Buy Standard

Standard
EN 13518:2004
English language
10 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Footwear - Test methods for uppers - Water resistanceSchuhe - Prüfverfahren für Obermaterialien - WasserbeständigkeitChaussures - Méthodes d'essai des tiges - Résistance a l'eauFootwear - Test methods for uppers - Water resistance61.060ObuvalaFootwearICS:Ta slovenski standard je istoveten z:EN 13518:2001SIST EN 13518:2004en01-januar-2004SIST EN 13518:2004SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13518December 2001ICS 61.060English versionFootwear - Test methods for uppers - Water resistanceChaussures - Méthodes d'essai des tiges - Résistance àl'eauSchuhe - Prüfverfahren für Schäfte - WasserbeständigkeitThis European Standard was approved by CEN on 16 November 2001.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2001 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13518:2001 ESIST EN 13518:2004

0,5 mm.4.1.3Means of reducing the separation of the cylinders (4.1.1) in each pair by a throw of 2,0 mm ± 0,1 mm;3,0 mm ± 0,2 mm; 4,0 mm ± 0,4 mm; or 6,0 mm ± 0,6 mm and returning them back to their original separation at arate of 50 cycles / min
± 1 cycles / min under a simple harmonic motion.SIST EN 13518:2004

60 mm ±1 mm.4.3Apparatus to measure the stiffness of the test specimen having:4.3.1Two cylinders of diameter (30,0 ± 0,5) mm mounted with their axes aligned and a maximum separation of40,0 mm ± 0,5 mm.4.3.2Means of moving the cylinders (see 4.3.1) together.4.3.3Means of measuring the reduction in distance between the two cylinders (4.3.1) to the nearest 0,5 mm.4.3.4Means of measuring the force resisting movement along the axis of the cylinders (4.3.1) to the nearest 5 N.4.3.5Ring shaped clamps of internal diameter adjustable between 30 mm and 40 mm, to fit around each cylinder(4.3.1).4.4Standard laboratory balance capable of measuring mass to the nearest 10 mg.4.5Abrasive paper, grade 180.4.6Pieces of soft absorbent lint free material.4.7Laboratory timer capable of recording time to the nearest second over a 5 s period.4.8Clock capable of recording time to the nearest minute over a 24 h period.4.9Distilled or deionised water complying with grade 3 of EN ISO 3696.5 Sampling and conditioning5.1Use the knife (see 4.2) to cut two rectangular test specimens 75 mm ± 2 mm
60 mm ± 1 mm. Cut one withits longer edges parallel to the along direction (X-axis as defined in EN13400 for shoe uppers, the backbonedirection for leather and the machine direction for other materials) of the material and cut the other test specimenperpendicular to this.For non-leather materials, cut test specimens from a range of positions across the full usable width and length ofthe sheet material. For a material with a woven structure this will prevent any two specimens containing the samewarp or weft threads.5.2Mark the principal direction of the material on each test specimen.5.3Unless otherwise specified, buff the outer surface of each test specimen lightly by rubbing it with the abrasivepaper (4.5) until the central 50 % of its surface area shows evidence of mild abrasion (scratching and matting)damage.NOTEVery thin surface finishes with low abrasion resistance are likely to be completely removed in some areas by thistreatment whilst thicker and more abrasion resistant finishes and coatings may be scratched and dulled only.5.4Store the test specimens in a conditioned atmosphere as specified in EN 12222 for at least 24 h prior to test.NOTESpecimens can be taken either from materials likely to be used for uppers or from made-up uppers or finishedfootwear.SIST EN 13518:2004
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.