Aerospace series - Circuit breakers, single-pole, temperature compensated, rated current 20 A to 50 A - Part 001: Technical specification

This standard specifies the single-pole temperature compensated circuit breakers with signal contacts, polarized or not, rated from 20 A to 50 A and used in aircraft on-board circuits. It describes specific environmental, electrical and mechanical characteristics and the stringency of tests to be applied according to test methods of EN 3841-100.
These circuit breakers are intended for use in aircraft with electrical supplies in accordance with EN 2282 (all categories).

Luft- und Raumfahrt - Schutzschalter, einpolig, temperaturkompensiert, Nennströme von 20 A bis 50 A - Teil 001: Technische Lieferbedingungen

Diese Norm legt einpolige, temperaturkompensierte Schutzschalter mit Signalkontakten, polarisiert oder nicht, Nennströme von 20 A bis 50 A, für den Einsatz in Luftfahrzeug Bordnetzen fest. Sie beschreibt die spezifi¬schen Umwelt , elektrischen und mechanischen Eigenschaften und den Umfang der entsprechend den Prüf¬verfahren nach EN 3841 100 durchzuführenden Prüfungen.
Diese Schutzschalter sind für den Einsatz in Luftfahrzeugen mit Stromversorgung nach EN 2282 (alle Katego¬rien) vorgesehen.

Série aérospatiale - Disjoncteurs unipolaires compensés en température, intensités nominales 20 A à 50 A - Partie 001 : Spécification technique

Aeronavtika - Odklopniki, enopolni, temperaturno kompenzirani, nazivni tok od 20 A do 50 A - 001. del: Tehnična specifikacija

General Information

Status
Published
Publication Date
22-Aug-2006
Withdrawal Date
27-Feb-2007
Technical Committee
Drafting Committee
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
01-Jun-2017

Relations

Buy Standard

Standard
EN 3661-001:2009
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luft- und Raumfahrt - Schutzschalter, einpolig, temperaturkompensiert, Nennströme von 20 A bis 50 A - Teil 001: Technische LieferbedingungenSérie aérospatiale - Disjoncteurs unipolaires compensés en température, intensités nominales 20 A à 50 A - Partie 001 : Spécification techniqueAerospace series - Circuit breakers, single-pole, temperature compensated, rated current 20 A to 50 A - Part 001: Technical specification49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 3661-001:2006SIST EN 3661-001:2009en,de01-junij-2009SIST EN 3661-001:2009SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 3661-001August 2006ICS 49.060 English VersionAerospace series - Circuit breakers, single-pole, temperaturecompensated, rated current 20 A to 50 A - Part 001: TechnicalspecificationSérie aérospatiale - Disjoncteurs unipolaires compensés entempérature, intensités nominales 20 A à 50 A - Partie 001: Spécification techniqueLuft- und Raumfahrt - Schutzschalter, einpolig,Temperaturkompensiert, Nennströme von 20 A bis 50 A -Teil 001: Technische LieferbedingungenThis European Standard was approved by CEN on 10 May 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 3661-001:2006: ESIST EN 3661-001:2009

Aerospace series — Copper or copper alloy conductors for electrical cables — Product standard. EN 2282,
Aerospace series — Characteristics of aircraft electrical supplies. EN 2825,
Aerospace series — Burning behaviour of non metallic materials under the influence of radiating heat and flames — Determination of smoke density. 1) EN 2826,
Aerospace series — Burning behaviour of non metallic materials under the influence of radiating heat and flames — Determination of gas components in the smoke.1) EN 3841-100*,
Aerospace series — Circuit breakers — Test Methods — Part 100: General. EN 3844-1,
Aerospace series — Flammability of non metallic materials — Part 1: Small burner test, vertical — Determination of the vertical flame propagation. 1) EN 9133,
Aerospace series — Quality management systems — Qualification Procedure for Aerospace Standards Parts. TR 6083,
Aerospace series — Cut-outs for installation of electrical components.2) MIL-I-81969/1A,
Installing and removal tools, connector electrical contact, type III, class 2, composition C.3) MIL-I-81969/14C,
Installing and removal tools, connector electrical contact, type III, class 2, composition B.3) 3 Terms and definitions For the purposes of this standard, the terms and definitions given in EN 3841-100 apply.  * And all its parts quoted. 1) Published as AECMA Prestandard at the date of publication of this standard. 2) Published as AECMA Technical Report at the date of publication of this standard. 3) Published by: Department of Defense (DOD), the Pentagon, Washington D.C. 20301 USA. SIST EN 3661-001:2009

6.2 Ratings See product standard. 6.3 Nominal voltage of main contacts See product standard. 6.4 Signal contact performances See Table 2. Table 2 — Signal contact performances Type of load 28 V d.c. 5 V d.c. 5 V a.c. a 28 V d.c. Resistive ≤ 0,5 A ≥ 3 mA Not used ≥ 3 mA Signal contact Lamp ≤ 0,2 A Not used 0,23 A Not used a Applicable on version without diode only.
NOTE 1 The circuit breaker status signalling function, open or closed shall be guaranteed after all the tests described in this specification. NOTE 2 In order to avoid any deterioration of the signalization circuit (contact and diode), the reception electrical test could be performed without exceeding the value recommended of 60 mW max. at 28 V d.c. max. (resistive load). SIST EN 3661-001:2009
...