Wood flooring and wood panelling and cladding - Determination of dimensional stability

This European Standard specifies a method of test to determine the dimensional changes and warp of the elements of wood flooring and wood panelling and cladding.

Holzfußböden und Wand- und Deckenbekleidungen aus Holz - Bestimmung der Dimensionsstabilität

Diese Europäische Norm legt ein Verfahren zur Bestimmung der Maßänderungen und Verformungen der Ele¬mente von Holzfußböden sowie Wand- und Deckenbekleidungen aus Holz fest.

Planchers en bois et lambris et bardages en bois - Détermination de la stabilité dimensionnelle

La présente Norme européenne définit une méthode d'essai pour déterminer les variations dimensionnelles et les déformations des éléments de planchers, lambris et bardages en bois.

Lesene talne obloge ter leseni stenski in stropni opaži - Ugotavljanje dimenzijske stabilnosti

Ta evropski standard določa preskusno metodo za ugotavljanje dimenzijskih sprememb in zvijanja lesenih talnih oblog ter stenskih in stropnih opažev.

General Information

Status
Published
Publication Date
26-Apr-2016
Withdrawal Date
30-Oct-2016
Current Stage
9092 - Decision on results of review/2YR ENQ - revise - Review Enquiry
Completion Date
23-Jun-2022

Relations

Buy Standard

Standard
EN 1910:2016
English language
13 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Lesene talne obloge ter leseni stenski in stropni opaži - Ugotavljanje dimenzijske stabilnostiHolzfußböden und Wand- und Deckenbekleidungen aus Holz - Bestimmung der DimensionsstabilitätPlanchers en bois et lambris et bardages en bois - Détermination de la stabilité dimensionnelleWood flooring and wood panelling and cladding - Determination of dimensional stability79.080Polizdelki iz lesaSemi-manufactures of timberICS:Ta slovenski standard je istoveten z:EN 1910:2016SIST EN 1910:2016en,fr,de01-september-2016SIST EN 1910:2016SLOVENSKI
STANDARDSIST EN 1910:20131DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1910
April
t r s x ICS
y {ä r z r Supersedes EN
s { s rã t r s uEnglish Version
Wood flooring and wood panelling and cladding æ Determination of dimensional stability Planchers en bois et lambris et bardages en bois æ Dßtermination de la stabilitß dimensionnelle
Holzfußböden und Wandæ und Deckenbekleidungen aus Holz æ Bestimmung der Dimensionsstabilität This European Standard was approved by CEN on
t r February
t r s xä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey andUnited Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
t r s x CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s { s rã t r s x ESIST EN 1910:2016

Condition No. 1 Condition No. 2 Temperaturea 20 °C 23 °C Relative humidityb Dry climate:
30 % 30 % Humid climate:
H1: or 75 % 75 % H2: 85 % 85 % a The permitted deviation for temperature is ± 2 °C. b The permitted deviation for relative humidity is ± 5 %. It shall be possible to change from one climate to the other within 24 h. 5.3 Trays The trays shall provide non-continuous support to the test specimen in the conditioning and stabilizing rooms. The clearance between supports shall be sufficient to allow the ventilation between the test specimens. 5.4 Measuring equipment All the dimensions shall be measured as defined in EN 13647. 5.5 Scales Scales shall be accurate to 0,1 % of the masses to be measured. 5.6 Oven The oven shall be able to operate at (103 ± 2)°C to bring the test specimens to the dry state. 6 Test specimens 6.1 Dimensions and shape Tests specimens are elements at the time of the first delivery. Measurements are made on the element. Elements more than 2000 mm require no end sealing. Elements between 2000 and 1000 mm shall have one end sealed. Elements less than or equal to 1000 mm shall have both ends sealed. The shortest length of a reduced element is 250 mm. SIST EN 1910:2016
...