EN ISO 6940:1995
(Main)Textile fabrics - Burning behaviour - Determination of ease of ignition of vertically oriented specimens (ISO 6940:1984, including Amendment 1:1993)
Textile fabrics - Burning behaviour - Determination of ease of ignition of vertically oriented specimens (ISO 6940:1984, including Amendment 1:1993)
This standard specifies a method for measurement of ease of ignition of vertically oriented textile fabrics in the form of single or multi-component fabrics.
Textilien - Brennverhalten - Bestimmung der Entzündbarkeit vertikal angeordneter Proben (ISO 6940:1984, einschließlich Änderung 1:1993)
Die vorliegende internationale Norm beschreibt eine Methode zur Bestimmung der Entzündbarkeit von senkrecht angeordneten textilen Flächengebilden, die für Bekleidung, Vorhänge und Gardinen bestimmt sind. Es kann sich dabei um Einzel- oder Verbundtextilien (beschichtet, gesteppt, mehrlagig, Sandwich-konstruktionen und ähnliche Kombinationen) handeln.
Textiles - Comportement au feu - Détermination de la facilité d'allumage d'éprouvettes orientées verticalement (ISO 6940:1984, amendement 1:1993 inclus)
La CEI 60335-2-107:2012 traite de la sécurité des tondeuses à gazon robotisées à axe vertical alimentées par batterie, la tension assignée maximale de la batterie étant de 75 V c.c. La charge de la batterie s'effectue sur le secteur et/ou par énergie solaire. La présente Norme internationale ne s'applique pas aux machines non robotisées telles que les coupe-gazon, coupe-bordure de gazon, coupe-bordure, tondeuses autoportées ou tondeuses à gazon à conducteur à pied. La présente norme ne s'applique pas à la CEM et aux dangers environnementaux (à l'exception du bruit). La présente norme traite des phénomènes dangereux courants, présentés par les tondeuses à gazon robotisées alimentées par batterie, en ce qui concerne leur utilisation dans l'environnement immédiat de la maison ou pour des fins analogues. Les exigences relatives aux batteries sont couvertes par la CEI 62133. La présente norme internationale n'est pas applicable aux machines qui sont fabriquées avant la date de publication de ce document par la CEI.
Cette publication doit être lue conjointement avec la CEI 60335-1:2001.
Tekstilije - Gorljivost - Ugotavljanje vnetljivosti navpično nameščenih preskušancev (ISO 6940:1984, vključno z dopolnilom 1:1993)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN ISO 6940:1999
01-marec-1999
7HNVWLOLMH*RUOMLYRVW8JRWDYOMDQMHYQHWOMLYRVWLQDYSLþQRQDPHãþHQLK
SUHVNXãDQFHY,62YNOMXþQR]GRSROQLORP
Textile fabrics - Burning behaviour - Determination of ease of ignition of vertically
oriented specimens (ISO 6940:1984, including Amendment 1:1993)
Textilien - Brennverhalten - Bestimmung der Entzündbarkeit vertikal angeordneter
Proben (ISO 6940:1984, einschließlich Änderung 1:1993)
Textiles - Comportement au feu - Détermination de la facilité d'allumage d'éprouvettes
orientées verticalement (ISO 6940:1984, amendement 1:1993 inclus)
Ta slovenski standard je istoveten z: EN ISO 6940:1995
ICS:
13.220.40 Sposobnost vžiga in Ignitability and burning
obnašanje materialov in behaviour of materials and
proizvodov pri gorenju products
59.080.30 Tkanine Textile fabrics
SIST EN ISO 6940:1999 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN ISO 6940:1999
---------------------- Page: 2 ----------------------
SIST EN ISO 6940:1999
---------------------- Page: 3 ----------------------
SIST EN ISO 6940:1999
---------------------- Page: 4 ----------------------
SIST EN ISO 6940:1999
---------------------- Page: 5 ----------------------
SIST EN ISO 6940:1999
---------------------- Page: 6 ----------------------
SIST EN ISO 6940:1999
International Standard
INTERNATIONAL ORGANIZATION FOR STANDARDIZATlON.MEXfiYHAPOfiHAR OPrAHM3AUMR I-IO CTAH~APTM3ALWl.ORGANlSATlON INTERNATIONALE DE NORMALISATION
Textile fabrics - Burning behaviour - Determination
of ease of ignition of vertically oriented specimens
Textiles - Comportemen t au feu - Dktermina tion de la faciiit6 d’allumage d%prouvettes orient&es verticalemen t
First edition - 1984-09-15
UDC 677.064 : 620.1 : 677.017.56 Ref. No. IS0 6940-1984 (E)
Descriptors : textiles, fabrics, tests, fire tests, determination, ignition, test equipment, burners.
0
m
- Price based on 9 pages
---------------------- Page: 7 ----------------------
SIST EN ISO 6940:1999
Foreword
IS0 (the International Organization for Standardization) is a worldwide federation of
national standards bodies (IS0 member bodies). The work of preparing International
Standards is normally carried out through IS0 technical committees. Every member
body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, govern-
mental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the technical committees are circulated to
the member bodies for approval before their acceptance as International Standards by
the IS0 Council. They are approved in accordance with IS0 procedures requiring at
least 75 % approval by the member bodies voting.
International Standard IS0 6940 was prepared by Technical Committee lSO/TC 38,
Textiles.
0 International Organization for Standardization, 1984
Printed in Switzerland
---------------------- Page: 8 ----------------------
SIST EN ISO 6940:1999
IS0 6940-1984 (E)
INTERNATIONAL STANDARD
- Burning behaviour - Determination
Textile fabrics
of ease of ignition of vertically oriented specimens
1 Scope and field of application 6 Apparatus and materials
This International Standard specifies a method for the measure-
6.1 Construction of testing equipment
ment of ease of ignition of vertically oriented textile fabrics in-
tended for apparel, curtains and draperies in the form of single-
Some products of combustion are corrosive. The equipment
or multi-component (coated, quilted, multilayered, sandwich
should be constructed of material which will not be adversely
construction and similar combinations) fabrics.
affected by the fumes.
This method should be used solely to assess the proper-
ties of materials or systems in response to heat and flame
6.2 Location of test
under controlled conditions. Results may not apply to
situations where there is restricted air supply or pro-
A location in which the air movement is less than 02 m/s at the
longed exposure to large sources of intense heat as in a
commencement of the test and is not further influenced by
conflagration.
mechanical devices operating during the test is required. The
volume of air surrounding the test location shall be such that
the test is not affected by any reduction of oxygen concen-
2 References
tration. Where an open-fronted cabinet is used for the test,
provision shall be made to permit the specimen to be mounted
IS0 139, Textiles - Standard atmospheres for conditioning
at least 300 mm from any wall.
and testing.
IS0 4880, Burning behaviour of textiles and textile products -
6.3 Templates
Vocabulary.
Flat rigid templates made of suitable material and of a size
I S 0 49 16, Textiles - Seam types - Classification and ter-
corresponding to the size of the specimens shall be used. Holes
minolog y.
approximately 2 mm diameter are drilled in each corner of the
template and positioned so that the distances between the
centres of the holes correspond to the distances between the
3 Definition
pins on the frame (see figure 1). The holes shall be located
equidistant about the vertical centrelines of the template (see
For the purpose of this International Standard, the following
the note in 7.2).
definition applies (see IS0 4880) :
3.1 minimum ignition time: Minimum time of exposure of
6.4 Specimen holders
a material to an ignition source to obtain sustained combustion
under specified test conditions.
6.4.1 Two specimen holders, each consisting of a metal frame
on which are mounted 4 pins to support the test specimen (see
figure 1). One specimen holder (No. 1) is for specimens
4 Principle
80 mm x 80 mm, the other specimen holder (No. 2) is for
specimens 200 mm x 80 mm. The pins for supporting the
A defined ignition flame from a specified burner is applied to
textile specimens which are vertically oriented. The time specimen have a maximum diameter of 2 mm and a minimum
length of 27 mm for locating the specimen in a plane at least
necessary to achieve ignition is determined as the mean of the
20 mm away from the frame.
measured times for ignition of the fabric.
NOTE - Attention is drawn to annex C regarding quality of ex-
NOTE - For the purpose of locating the specimen in a plane away
perimental techniques.
from the frame, spacer stubs 2 mm diameter may be provided adjacent
to the pins.
5 Health and safety of test operators
6.4.2 If provision is made for multiple testing of specimens on
the No. 1 specimen holder, the location of the pins shall be
Burning of textiles may produce smoke and toxic gases which
such that a space of 10 mm is provided between adjacent
can affect the health of operators. The testing area should be
mounted specimens.
cleared of smoke and fumes by suitable means.
1
---------------------- Page: 9 ----------------------
SIST EN ISO 6940:1999
IS0 69404984 (E)
8 Procedure
6.5 Gas burner
A gas burner as described in annex A.
8.1 Carry out the test in an atmosphere having a temperature
between 10 and 30 OC and a relative humidity between 15 %
NOTE - Small differences in the design and dimensions of the burner and 80 % .
can influence the configuration of the burner flame and so affect the
results of the tests.
8.2 Light the burner and preheat it for 2 min. Adjust the
flame height to 40 & 2 mm measured as the distance between
6.6 Gas
the top of the burner tube and the tip of the yellow part of the
flame when the burner is vertically oriented and the flame is
Commercial grade propane or butane gas.
viewed in dim light.
6.7 Timing device
8.3 Begin testing each specimen within 2 min of removing it
from the conditioning atmosphere. If testing is not being per-
A timing device to control and measure the application time of
formed immediately, place the specimens in sealed containers
the flame accurate to 0,2 s or better. The device shall have pro-
until testing begins.
vision for setting time intervals of 1,0 s or less.
8.4 Place the specimen on the pins of the test frame making
certain that the pins pass through the points marked off from
7 Test specimens
the template and that the specimen is at least 20 mm removed
from the frame. Fit the frame on the support so that the
7.1 Size
specimen is vertical. (See 7.2.)
The size of each specimen shall be as follows (see 8.6) :
8.5 For all fabrics, position the burner as described in 8.5. I.
Where a fabric intended for curtains and drapes fails to ignite in
a) for frame 1 : 80 mm x 80 mm, tolerance +z
the position of the burner described in 8.5.1, the fabric may be
(Figure 1, dimension X = 70)
ignited by the method described in 8.5.2.
b) for frame 2: 200 mm x 80 mm, tolerance +z
8.5.1 Surface ignition : Position the burner perpendicular to
the surface of the specimen such that the axis of the burner is
(Figure 1, dimension XI = 190)
20 mm above the line of the lower pins in line with the vertical
centreline of the face of the specimen [see figure 2a)l. The end
7.2 Pin location marks
of the burner is 17 mm from the face of the specimen.
Place the template (see 6.3) for the appropriate specimen size
8.5.2 Edge ignition : Position the burner in front of and below
centrally on top of the specimen and, by using the holes in the
the specimen such that it lies in a plane passing through the
template, mark the position through which the pins must pass.
vertical centreline of the specimen and perpendicular to its face
NOTE - Where the fabric is of open construction (e.g. scrim, gauze), [see figure 2b)3, such that the longitudinal axis is inclined up-
small pieces of adhesive tape may be affixed to the fabric at the pin wards at 30° to the vertical towards the lower edge of the
sites and the pin positions marked on the tape.
specimen. The distance between the tip of the burner and the
lower edge of the specimen is 20 mm.
7.3 Number
NOTE - The edge of the specimen should bisect the flame.
A sufficient number of specimens shall be tested until at least
8.6 Apply the flame to the 80 mm x 80 mm specimen on
five cases of ignition and five cases of non-ignition occur for
each of the length direction and width direction on the size of frame No. 1 for a time period which preliminary testing in-
dicates will approximate to the minimum ignition time. Ignition
frame used for the fabric under test (see 8.8). For surface igni-
shall be deemed to have occurred if either the flame on the
tion, where the two surfaces of the specimen are dissimilar or
preliminary examination indicates it (see annex C), each face of specimen persists for a period of at least 5 s after removal of
the igniting flame, or if the specimen burns to the top or to the
the sample shall be tested in this manner (see 8.8 and 8.9).
vertical edges of the specimen, after removal of the igniting
flame.
7.4 Conditioning of test specimens
8.7 If the specimen burns to the top edge of the specimen
Condition test specimens in one of the following ways:
during application of the igniting flame, or within 5 s of remov-
a) in the standard temperate atmosphere of 20 & 2 OC
ing the igniting flame, retest the sample using a
and (65 fI 2) % rh in accordance with IS0 139;
200 mm x 80 mm specimen on frame No. 2.
b) drying in an oven at 105 + 2 OC for not less than 1 h,
NOTE - Care should be taken to observe the burning behaviour of tex-
then cooling in a desiccator for at least 30 min; or
tiles which have been given flame-retardant treatments or which melt.
any other conditioning atmosphere as agreed by the in-
c)
It may be necessary to commence testing such textiles from 1 s flame
terested parties. application time.
---------------------- Page: 10 ----------------------
SIST EN ISO 6940:1999
IS0 69404984 (El
10 Test report
8.8 Record the timer setting and whether the test specimen
ignites. Extinguish any flame on the specimen if ignition has oc-
The test report shall include the following particulars:
curred then reduce the timer setting by 1 s. If ignition has not
occurred increase the time setting by 1 s up to a maximum time
a) a statement that the test was carried out in accordance
of 20 s, or as indicated in the applicable product standard.
with this International Standard and details of alterations to
Repeat each
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.