EN 14707:2005
(Main)Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature for preformed pipe insulation
Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature for preformed pipe insulation
This European Standard specifies the equipment and procedures for determining the maximum service temperature for preformed pipe insulation. It is applicable to thermal insulating products.
Wärmedämmstoffe für die Haustechnik und für betriebstechnische Anlagen - Bestimmung der oberen Anwendungsgrenztemperatur von vorgeformten Rohrdämmstoffen
Dieses Dokument legt Prüfeinrichtungen und Verfahren zur Bestimmung der oberen Anwendungsgrenz-temperatur
von vorgeformten Rohrdämmstoffen fest. Es gilt für Wärmedämmprodukte.
Produits isolants thermiques pour l'équipement du bâtiment et les installations industrielles - Détermination de la température maximale de service des coquilles isolantes préformées
La présente Norme européenne spécifie l'équipement et les modes opératoires servant à déterminer la température maximale de service des coquilles isolantes préformées. Elle s’applique aux produits isolants thermiques.
Toplotnoizolacijski proizvodi za opremo stavb in industrijske inštalacije – Ugotavljanje najvišje temperature servisiranja predoblikovanih cevnih izolacij
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature for preformed pipe insulationToplotnoizolacijski proizvodi za opremo stavb in industrijske inštalacije – Ugotavljanje najvišje temperature servisiranja
predoblikovanih cevnih izolacijProduits isolants thermiques pour l'équipement du bâtiment et les installations industrielles - Détermination de la température maximale de service des coquilles isolantes préforméesWärmedämmstoffe für die Haustechnik und für betriebstechnische Anlagen - Bestimmung der oberen Anwendungsgrenztemperatur von vorgeformten RohrdämmstoffenTa slovenski standard je istoveten z:EN 14707:2005SIST EN 14707:2006en91.100.60ICS:SLOVENSKI
STANDARDSIST EN 14707:200601-maj-2006
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 14707November 2005ICS 91.100.60 English VersionThermal insulating products for building equipment and industrialinstallations - Determination of maximum service temperature forpreformed pipe insulationProduits isolants thermiques pour l'équipement du bâtimentet les installations industrielles - Détermination de latempérature maximale de service des coquilles isolantespréforméesWärmedämmstoffe für die Haustechnik und fürbetriebstechnische Anlagen - Bestimmung der oberenAnwendungsgrenztemperatur von vorgeformtenRohrdämmstoffenThis European Standard was approved by CEN on 19 October 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2005 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14707:2005: E
Modifications of and additions to the general test method for mineral wool products.13 Annex B (normative)
Modifications of and additions to the general test method for polyethylene foam (PEF) and flexible elastomeric foam (FEF) products.15 Annex C (normative)
Modifications of and additions to the general test method for phenolic foam products.18 Bibliography.20
Key 1 Device for measuring thickness, e. g. electromechanical
device 2a
Test length of the test specimen 2b Test specimen end guard 3 End insulation 4 Small gap
5 Circumferential joints 6 Thermocouples 7 Hot pipe 8 Power supply and temperature control a) General arrangement
All dimensions in millimetres
Key 1 Device for measuring thickness, e.g. electromechanical device 2 Thermocouple 3 Hot pipe
4 Test specimen 5 Flexible metal foil 6 Weights for loading b) Test specimen loading arrangement Figure 1 — Example of an apparatus for determining maximum service temperature
6 Test specimens 6.1 Dimensions of test specimens Length: The test specimen, length (1 000 ± 10) mm, shall be cut at right angles to its length to give two end guards, length each (250 ± 5) mm, and a test length of (500 ± 5) mm. Thickness: The thickness shall be 100 mm or the largest thickness below 100 mm available. Inside diameter: Two sizes shall be tested, one between 25 mm and 65 mm and the other between 85 mm and 220 mm. The dimensions shall be as specified in the relevant product standard or annex to this European Standard. NOTE 1 In the absence of a product standard or any other European Technical Specification, the dimensions may be agreed between parties. NOTE 2 Testing may be performed on multi-layer systems to simulate the conditions existing in the application. If the pipe insulation is cut from a homogeneous, isotropic flat product, then the maximum service temperature can be obtained from tests carried out on the flat product with similar properties in accordance with EN 14706. 6.2 Number of test specimens The number of test specimens shall be as specified in the relevant product standard. If the number is not specified, then at least one test specimen for each size shall be used. NOTE In the absence of a product standard or any other European technical specification the number of test specimens may be agreed between parties. 6.3 Conditioning of test specimens The test specimens shall be stored for at least 6 h at (23 ± 5) °C. In case of dispute they shall be stored at (23 ± 2) °C and (50 ± 5
...