Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance

Applies to ID connections which are accessible for tests and measurements, and which are made with: -appropriately designed ID terminations -wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter -wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-section.

Lötfreie elektrische Verbindungen - Teil 3: Lötfreie zugängliche Schneidklemmverbindungen - Allgemeine Anforderungen, Prüfverfahren und Anwendungshinweise

Connexions sans soudure - Partie 3: Connexions autodénudantes accessibles sans soudure - Règles générales, méthodes d'essai et guide pratique

Est applicable aux connexions CAD qui sont accessibles pour les essais et les mesures et qui sont composées de: Contacts CAD de conception appropriée; fils à conducteur circulaire massif de diamètre nominal 0,25 mm à 3,6 mm; fils à conducteur divisé de section 0,05 mm2 à 10 mm2.

Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance (IEC 60352-3:1993)

General Information

Status
Withdrawn
Publication Date
10-Oct-1994
Withdrawal Date
14-Jul-1995
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
14-May-2023
Completion Date
14-May-2023

Relations

Buy Standard

Standard
EN 60352-3:2002
English language
36 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2002
Solderless connections - Part 3: Solderless accessible insulation displacement
connections - General requirements, test methods and practical guidance (IEC
60352-3:1993)
Solderless connections -- Part 3: Solderless accessible insulation displacement
connections - General requirements, test methods and practical guidance
Lötfreie elektrische Verbindungen -- Teil 3: Lötfreie zugängliche
Schneidklemmverbindungen - Allgemeine Anforderungen, Prüfverfahren und
Anwendungshinweise
Connexions sans soudure -- Partie 3: Connexions autodénudantes accessibles sans
soudure - Règles générales, méthodes d'essai et guide pratique
Ta slovenski standard je istoveten z: EN 60352-3:1994
ICS:
29.120.20 Spojni elementi Connecting devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

NORME CEI
INTERNATIONALE IEC
352-3
INTERNATIONAL
Première édition
STANDARD
First edition
1993-02
Connexions sans soudure
Partie 3:
Connexions autodénudantes accessibles
sans soudure — Règles générales, méthodes
d'essai et guide pratique
Solderless connections
Part 3:
Solderless accessible insulation displacement
connections — General requirements, test methods
and practical guidance
© CEI 1993 Droits de reproduction réservés — Copyright — all rights reserved
Aucune partie de cette publication ne peut étre reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun pro- any form or by any means, electronic or mechanical,
cédé, électronique ou mécanique, y compris la photocopie et including photocopying and microfilm, without permission
les microfilms, sans l'accord écrit de l'éditeur. in writing from the publisher.
Genève, Suisse
Bureau Central de la Commission Electrotechnique Internationale 3, rue de Varembé
Commission Electrotechnique Internationale CODE PRIX
International Electrotechnical Commission PRICE CODE
IEC MemutyHapoaHaa 3neKtpoîexHH4eceaa IiouHccsn
 Pour prix, voir catalogue en vigueur

For price, see current catalogue

- 3 -
352-3 © IEC: 1993
CONTENTS
Page
FOREWORD 5
INTRODUCTION 7
SECTION 1: GENERAL
Clause
1 Scope 9
2 Object 9
3 Normative references 9
4 Definitions
5 IEC type designation
SECTION 2: REQUIREMENTS
17 6 Workmanship
7 Tools
Insulation displacement terminations (ID terminations) 8
Wires
21 10 Accessible insulation displacement connections (ID connections)
SECTION 3: TESTS
11 Testing
12 Type tests
13 Test schedules
SECTION 4: PRACTICAL GUIDANCE
55 14 Current-carrying capacity
55 15 Tool information
55 16 Termination information
17 Wire information
18 Connection information
352-3 © IEC: 1993 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
SOLDERLESS CONNECTIONS
Part 3: Solderless accessible insulation displacement connections —
General requirements, test methods and practical guidance
FOREWORD
The formal decisions or agreements of the IEC on technical matters, prepared by Technical Committees on
1)
which all the National Committees having a special interest therein are represented, express, as nearly as
possible, an international consensus of opinion on the subjects dealt with.
They have the form of recommendations for international use and they are accepted by the National
2)
Committees in that sense.
In order to promote international unification, the IEC expresses the wish that all National Committees
3)
should adopt the text of the IEC recommendation for their national rules in so far as national conditions will
permit. Any divergence between the IEC recommendation and the corresponding national rules should, as
far as possible, be clearly indicated in the latter.
The IEC has not laid down any procedure concerning marking as an indication of approval and has no
4)
responsibility when an item of equipment is declared to comply with one of its recommendations.
International Standard IEC 352-3 has been prepared by IEC technical committee 48:
Electromechanical components and mechanical structures for electronic equipment.
The text of this standard is based on the following documents:
DIS Report on Voting
48(CO)339
48(CO)331
Full information on the voting for the approval of this standard can be found in the Voting
Report indicated in the above table.

352-3 © IEC: 1993 — 7 —
INTRODUCTION
Two standards are available on solderless insulation displacement connections:
Part 3: Solderless accessible insulation displacement connections – General require-
ments, test methods and practical guidance;
Part 4: Solderless non-accessible insulation displacement connections – General
requirements, test methods and practical guidance.
This standard includes requirements, tests and practical guidance information.
Two test schedules are provided:
The Basic Test Schedule applies to insulation displacement connections which

conform to all requirements of section 2.
These requirements are derived from experience with successful applications of such
connections.
– The Full Test Schedule applies to insulation displacement connections which do not
fully conform to all requirements of section 2, for example those which are manu-
factured using materials or surface finishes not included in section 2.
This philosophy permits cost and time effective performance verification using a limited
Basic Test Schedule for established connections and an expanded Full Test Schedule
for connections requiring more extensive performance validation.
NOTE - In this standard the term Insulation displacement" is abbreviated to "ID", for example "ID connec-
tion" , "ID termination".
Accessible ID Non-accessible ID

connection
connection
IEC 026/93
IEC 025193
Figure 1 – Example of accessible and non-accessible insulation displacement connection

Oo
IEC: 1993 352-3 — 9 -
SOLDERLESS CONNECTIONS
Part 3: Solderless accessible insulation displacement connections –
General requirements, test methods and practical guidance
SECTION 1: GENERAL
1 Scope
This part of IEC 352 is applicable to ID connections which are accessible for tests and
measurements according to section 3 and which are made with:
appropriately designed ID terminations;
— wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter;
— 2 cross-section;
wires having stranded conductors of 0,05 mm 2 to 10 mm
for use in telecommunication equipment and in electronic devices employing similar
techniques.
Information on materials and data from industrial experience is included in addition to the
test procedures to provide electrically stable connections under prescribed environmental
conditions.
2 Object
To determine the suitability of accessible ID connections under specified mechanical,
electrical and atmospheric conditions.
There are different designs and materials for ID terminations in use. For this reason only
rformance require-
fundamental parameters of the termination are specified while the pe
ments of the wire and the complete connection are specified in full detail.
To provide a means of comparing test results when the tools used to make the connec-
tions are of different designs or manufacture.
3 Normative references
The following normative documents contain provisions which, through reference in this
text, constitute provisions of this part of IEC 352. At the time of publication, the editions
indicated were valid. All normative documents are subject to revision, and parties to agree-
ments based on this part of IEC 352 are encouraged to investigate the possibility of apply-
ing the most recent editions of the normative documents indicated below. Members of IEC
and ISO maintain registers of currently valid International Standards.
IEC 50(581): 1978, International Electrotechnical Vocabulary (IEV) — Chapter 581: Electro-
mechanical components for electronic equipment

352-3 © IEC: 1993 - 11 -
IEC 68-1: 1988, Environmental testing - Part 1: General and guidance
IEC 68-2-60 TTD: 1989, Environmental testing - Part 2: Tests - Test Ke: Corrosion tests
in artificial atmosphere at very low concentration of polluting gas(es)
IEC 189-3: 1988, Low-frequency cables and wires with PVC insulation and PVC sheath -
Part 3: Equipment wires with solid or stranded conductor, PVC insulated, in singles, pairs
and triples.
Amendment 1 (1989)
IEC 352-4, Solderless connections - Part 4: Solderless non-accessible insulation displace-
ment connections - General requirements, tests methods and practical guidance (under
consideration)
IEC 512-1: 1984, Electromechanical components for electronic equipment; basic testing
1: General.
procedures and measuring methods - Pa rt
Amendment 1 (1988)
Electromechanical components for electronic equipment, basic testing
IEC 512-2: 1985,
procedures and measuring methods - Part 2: General examination, electrical continuity
and contact resistance tests, insulation tests and voltage stress tests
Electromechanical components for electronic equipment; basic testing
IEC 512-4: 1976,
procedures and measuring methods - Part 4: Dynamic stress tests
IEC 512-5: 1992, Electromechanical components for electronic equipment; basic testing
procedures and measuring methods - Part 5: Impact tests (free components), static load
tests (fixed components), endurance tests and overload tests
IEC 512-6: 1984, Electromechanical components for electronic equipment; basic testing
rt 6: Climatic tests and soldering tests
procedures and measuring methods - Pa
Low-frequency miniature equipment wires with solid or stranded conductor,
IEC 673: 1980,
fluorinated polyhydrocarbon type insulation, single.
Amendment 3 (1989)
4 Definitions
Terms and definitions used in and applicable to this part of IEC 352 are included in
IEC 50(581). IEC 512-1 also contains some applicable terms and definitions.

352-3 © IEC: 1993 - 13 -
For the purpose of this part of IEC 352, the following additional terms and definitions
shall apply.
4.1
Insulation displacement connection (ID connection)
A solderless electrical connection made by inserting a single wire into a precisely
controlled slot in a termination such that the sides of the slot displace the insulation and
deform the conductor of a solid wire or strands of stranded wire to produce a gas-tight
connection.
Ribbon cable with
stranded conductors
!EC 027193
Figure 2 - Insulation displacement connection
4.1.1
Accessible insulation displacement connection (accessible ID connection)
An ID connection in which it is possible to access test points for carrying out mechanical
tests (for example, transverse extraction force) and electrical measurements (for example,
contact resistance) without deactivation of any design feature intended to establish and/or
maintain the ID connection.
4.1.2
Non-accessible insulation displacement connection (non-accessible ID connection)
(See IEC 352-4, under consideration)
An ID connection in which it is not possible to access test points for carrying out mecha-
nical tests such as transverse extraction force and some electrical measurements (for ex-
ample, contact resistance) without deactivation of any design feature intended to establish
and/or maintain the ID connection, mainly where the ID connection is enclosed in a compo-
nent.
4.2
Insulation displacement termination (ID termination)
A termination designed to accept a wire for the purpose of establishing an ID connection.
4.2.1
Reusable insulation displacement termination (reusable ID termination)
An ID termination that can be used more than once.

352-3 © I EC: 1993 - 15 -
Non-reusable insulation displacement termination (non-reusable ID termination)
4.2.2
An ID termination that can be used only once.
4.3 Slot
Strain relief slot or second
connection slot
!EC 028/93
Figure 3 - Slot
4.3.1 Connection slot
The specially shaped opening in an ID termination suitable to displace the insulation of a
wire and to ensure a gas-tight connection between the termination and the conductor(s) of
the wire.
In certain cases a second connection slot is used to provide for a double connection.
4.3.2 Strain relief slot
The specially shaped opening in an ID termination suitable to provide for strain relief.
4.4 Beam
The specially shaped metallic part of an ID termination on each side of the slot.
Beams
Slot
ID termination
IEC 029/93
Figure 4 - Beam
352-3 © I EC: 1993 - 17 -
4.5 Apparent diameter (of a stranded conductor)
The diameter of the circumscribing circle of the bundle of strands.
4.6 Guiding block (see IEC 352-4)
A specially shaped part of a component, for example, a connector, which guides/inserts
the wire(s) into the slot(s). Additionally it may provide for other mechanical features, for
example, fixing the wire(s) in correct position(s), strain relief of the ID connection(s),
secondary loading on the ID termination(s) or beams.
Guiding block
Ribbon cable or
single wires
ID termination
IEC 030193
Figure 5 - Guiding block
4.7 Wire insertion tool
A hand- or power-operated tool for producing an ID connection by inserting the wire(s) in a
controlled manner to a predetermined position into the slot(s).
4.8 Wire extraction tool
A device for extracting the wire(s) from the ID termination.
5 IEC type designation
Not applicable.
SECTION 2: REQUIREMENTS
6 Workmanship
The connections shall be processed in a careful and workmanlike manner, in accordance
with good current practice.
7 Tools
Tools shall be used and inspected according to the instructions given by the manufacturer.

352-3 ©IEC: 1993 - 19 -
A tool shall be able to make uniformly reliable connections during its useful life.
A tool shall be designed and shall operate in such a manner that any damage to the ID
termination and/or to the wire is avoided.
A tool shall provide for a corre
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.