IEC 63171-6:2020, covers 2-way and 4-way (data/power) shielded free and fixed connectors for data transmission with frequencies up to 600 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively. This document specifies several properties overlapping with specifications in the IEC 63171 series which have been drafted later. In case of conflict the specifications within this document prevail. Keywords: Connectors for data transmission

  • Standard
    54 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-28-100:2019 is available as IEC 60512-28-100:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60512-28-100:2019 specifies the test methods for signal integrity and transmission performance for connectors specified in respective parts of IEC 60603-7, IEC 61076-1, IEC 61076-2, and IEC 61076-3 standards for connecting hardware applications up to 2 000 MHz. It is also suitable for testing lower frequency connectors, however, the test methodology specified in the detail specification for any given connector remains the reference conformance test for that connector. The above list of connector series of standards does not preclude referencing this document in other connector manufacturer’s specifications or published standards. Test procedures provided herein are: - insertion loss, test 28a; - return loss, test 28b; - near-end crosstalk (NEXT) test 28c; - far-end crosstalk (FEXT), test 28d; - transverse conversion loss (TCL), test 28f; - transverse conversion transfer loss (TCTL), test 28g. Other test procedures referenced herein are: - transfer impedance (ZT), see IEC 60512-26-100, test 26e. - for coupling attenuation (aC), see IEC 62153 4 12. This second edition cancels and replaces the first edition, issued in 2013, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - The title is revised from 1 000 MHz to 2 000 MHz to reflect the range of frequencies which may be tested. - All tables and requirements have been revised up to 2 000 MHz. Key words: Connectors, Signal Integrity Tests

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-3-123:2019. covers hybrid rectangular connectors with a 3 poles 16 A electric portion for power supply and a duplex fibre optic connector type LC portion for data transmission. These connectors consist of fixed and free connectors, either rewirable or non-rewirable (for both portions) and use the rectangular push-pull housing described in IEC 61076-3-117 with IP65/IP67 degree of protection, for harsh applications. The mating dimensions of such housings allow fulfilling the performance class Category I according to IEC 61753-1-3 in regards to the fibre optic portion of the connector with the exception of the operating temperature range which is –25 °C/+70 °C. The electric portion may have different rated insulation voltages. Male connectors have 3 electric round contacts Ø1,6 mm, with 16 A rated current. The fibre optic portion provides data transmission by using the common mating configurations for all variants of the type LC duplex fibre optic connectors as defined in IEC 61754-20, for dedicated fibre types and fibre termination technology covered therein. The different codings provided by this document prevent the mating of accordingly coded male or female connectors to any other similarly sized interfaces covered by other standards and the cross-mating between the different codings provided by this document. Key words: Rectangular Connectors, Hybrid Connectors, Power Supply and Fiber Optic Data Transmission.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-11-1:2019 when required by the detail (product) specification, is used for testing connectors within the scope of IEC technical committee 48. This test may also be used for similar devices (i.e. when the degradation mechanisms are the same) when specified in a detail (product) specification. The object of this test is to define a standard test method to assess the ability of connectors to function in a specified manner, in a specified environment which might be encountered during normal use, including storage. This document provides a standard composite test method for determining the suitability of connectors when subjected to environmental conditions consisting of a sequence of temperature, humidity and, where required, low air pressure environmental stresses. Key words: Connectors, Climatic Tests

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61076 covers 10-way, shielded, free and fixed rectangular connectors for data transmission with frequencies up to 500 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively. Connectors covered in this document are provided in three codings that differ only for the position of the polarization key and keyway, in view of their differently intended use: - Connectors Type A and C are intended for 10/100 Mbit/s as well as for 1/ 2,5 / 5 /10 Gbit/s Ethernet communication. - Connectors Type B are intended for all other non-Ethernet applications such as signalling, serial or other industrial bus communication systems. A-coding: The 45° cut corner used as polarization key and keyway system is located on the lower left corner of the male fixed connector (viewed from mating face) (Figures 5a, 5b). B-coding: The 45° cut corner is located on the upper left corner of the male fixed connector (Figures 5c, 5d). C-coding: There are two 45° corners located at the upper left and lower left corner (Figures 5e, 5f). In this document, the three codings, A, B, and C are designated as "Type A", "Type B" and .Type C".

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60512 is used for testing connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power, such as ISO/IEC 11801 Class D (or better), balanced cabling in support of IEEE Std 802.3bt, (PoE Plus - Power over Ethernet Plus). The object of this document is to detail a test schedule to determine the ability of pairs of connectors to withstand a sequence of tests with a total of 100 engagements and separations. The electrical current is passed through the connectors during the separation (unmating) step only, in accordance with IEC 60512-9-3.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60512 defines a standard test method for measuring the shielding effectiveness SE of a shielded connector, or of a connector not provided with integral shield once fitted with a shielding accessory and terminated with a screened cable. The complete assembly has a continuous 360° shielding capability throughout its length. NOTE 1 Practically, continuous 360° shielding is not always achievable based on the geometry of the connector. NOTE 2 Shielding" is used in this document with the same meaning as "screening". This test method can be applied to shielded connectors and to connector accessories with shielding capability. The following different connector designs can be tested: - circular connectors; - rectangular connectors; - connectors for printed boards; - connector shielding accessories. NOTE 3 For the definition of "accessory" see IEV 581-24-10. A shielding accessory i.e. an accessory that confers shielding to a non-inherently shielded connector, may be a suitable set of shielded housings providing electrical continuity, along the mated connector set, between the screen of the (screened) cable at the cable outlet of the free cable connector housing and the metallic mounting surface for the fixed connector housing. The free connector housing is provided with a cable screen clamp. This test method utilizes the principle that the intrinsic shielding property of the connector/accessory/cable assembly is its surface transfer impedance ZT which can be expressed as the longitudinal voltage inside the shield, relative to the current flow on the outside shell. This test method is based on two impedance-matched circuits. See Figure 1 for the measurement principle. The connector specimen under test is integrated into the secondary circuit 02. The impedance-matched injection line of the primary circuit 01, which activates the electromagnetic field, runs parallel to the surface of the specimen under test. This test is also suitable for measuring the shielding effectiveness of a connector fitted with triaxial contacts terminated with shielded, twisted pair cables, as used in data bus systems. NOTE 4 This standard has been adopted by ASD-STAN (formerly known as AECMA) as EN 2591-212.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-1:2018 is available as IEC 60512-1:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60512-1:2018 is intended to be used as a basis for tests and measurements specifications for electrical connectors. It provides guidance and reference for tests and measurements within the IEC 60512 series. It includes the description and the practice of the various phases of tests and measurements (preparation, tests and measurements, requirements, documentation), in addition to basic terms and definitions applicable to any part of the IEC 60512 series. This standard shall be used in conjunction with IEC 60512-1-101 and relevant part(s) of series IEC 60512. Part 60512-1-100 provides the list of the existing test and measuring methods published within series IEC 60512. Detail tests and measurements specifications are applicable to electrical connectors and their components (e.g. connector inserts, connector housings, locking mechanisms, contacts and terminations) within the scope of technical committee 48. They may also be used for similar devices when specified in a detail product specification. Detail tests and measurements specifications are used in conjunction with detail product specifications which prescribe the tests to be used, the required degree of severity for each of them and the permissible performance limits. The detail product specification also specifies the deviations in procedures, which may be required when applying a test to the type of connector or its component under consideration, and it further specifies any special procedures which may be required. This fifth edition cancels and replaces the fourth edition, published in 2001. It constitutes a technical revision. This edition includes the following main technical changes with respect to the previous edition: – in Clause 3, only terms relating to the testing are defined, and IEC 61076-1 is referred to for terms of connectors. – Clause 4 (Numbering of tests and measurement specification) is added. – Subclause 5.1.2 (Calibration) is added. – in Clause 6 (Test), test procedure follows IEC 60068-1. Key words: Connectors, Test Specification

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-15-2:2018 This part of IEC 60512, when required by the detail (product) specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail (product) specification. The object of this document is to detail a standard test method to assess the effectiveness of the retaining system of a connector insert within a connector housing to withstand axial forces likely to be encountered during normal use, i.e. the highest insertion and withdrawal forces into/from a mating counterpart, without the connector insert being dislodged from the connector housing. The test method detailed in this document is a companion to the one detailed in IEC 60512-15-3 This second edition cancels and replaces the first edition, published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: the test method B (pressure method) suitable for testing hermetic connector has been added. This edition reflects IEC 60512-1-101, Blank detail specification.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-8-3:2018 this part of IEC 60512, when required by the detail (product) specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices, when specified in a detail (product) specification. The object of this document is to detail a standard test method to assess the robustness of the actuating lever of a connector mating or release mechanism. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: this edition reflects IEC 60512-1-101, Blank detail specification and Subclause 4.2 (Preparation of specimen) is improved.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-3-119:2017(E) establishes specifications and test requirements for 10-way shielded and unshielded rectangular, free and fixed connectors, with push-pull coupling, for data transmission with frequencies up to 100 MHz and for use in industrial environments. This document specifies free and fixed connectors with round contacts, suitable for screw or crimp terminations. Other terminations techniques, such as solder or printed board connections are upon agreement between manufacturer and user. The free and fixed connectors have a push-pull locking mechanism for IP65 and IP67 protection according to IEC 60529. Connectors according this document are without breaking capacity COC according to 3.9 of IEC 61984:2008, therefore they are not intended to be engaged or disengaged in normal use when live or under load, if not otherwise specified by the manufacturer. Key words: Connectors, Rectangular Connectors, 10 Way Connectors, Push-Pull Coupling

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-111:2017 specifies 4 to 6-way circular connectors with M12 screw-locking with current ratings up to 16 A and voltage ratings of 63 V or 630 V, that are typically used for power supply and power applications in industrial premises. These connectors consist of both, fixed and free connectors either rewireable or non-rewireable, with M12 screw-locking. Male connectors have round contacts Ø1,0 mm and Ø1,5 mm. The different codings provided by this document prevent the mating of accordingly coded male or female connectors to any other similarly sized interfaces, covered by other standards and the cross-mating between the different codings provided by this document. M12 is the dimension of the thread of the screw locking mechanism of these circular connectors. Keywords: Connectors, Circular Connectors, M12.

  • Standard
    77 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-3-104:2017(E) establishes uniform specifications, type testing requirements for 8 way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz, and used as category 7A connectors in class FA cabling systems specified in ISO/IEC 11801-1. It contains all test methods and sequences, severity and preferred values for dimensions and characteristics. This third edition of IEC 61076-3-104 cancels and replaces the second edition, published in 2006, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - the title has been changed to incorporate transmissions with frequencies up to 2 000 MHz; - the drawings of some styles have been corrected for clarification; - Figures 23 and 24 have been updated; - Figure 3 has been updated to include reference dimensions and dimensional format changes; - the dimensions of Figure 7 have been updated; - the type designation and ordering information has been removed for consistency with the most updated sectional specification; - the test schedule was updated to include appropriate IEC 60512 Test Nos; - the electrical performance requirements have been revised for 2 GHz level and interchangeability information has been added for performance categories.

  • Standard
    89 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-3-122:2017 covers 8-way, shielded, free and fixed rectangular connectors for I/O and Gigabit Ethernet applications, suitable for use in harsh environments, and is intended to specify the common dimensions, mechanical, electrical and environmental characteristics and tests for this family of connectors.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-113:2017 describes M12 circular connectors with two data pairs and power contacts with current ratings up to 12 A, that are typically used for data and power applications in industrial premises. These connectors consist of both fixed and free connectors either rewireable or non rewireable, with screw-locking. Male connectors have round contacts diameters of 1,50 mm, 1,00 mm and 0,60 mm. The different codings provided by this document prevent the mating of accordingly coded male or female connectors to any other similarly sized interfaces covered by other standards and the cross-mating between the different codings provided by this document. M12 is the dimension of the thread of the screw locking mechanism of these circular connectors. Key words: Connectors, Circular Connectors, M12.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-3-120:2016 describes a 2 pole 30 A rectangular power connector with snap locking (hereinafter shortly referred to as connector), including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods. The products covered by this detail specification are connectors without breaking capacity according to IEC 61984:2008 which are mainly for use in DC power distribution equipment in the telecommunications field, such as in outdoor telecom modules, distributed frames, etc. Key words: Connectors, Rectangular Connectors, Rewirable, Snap Locking

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60603-7-82:2016 covers 8-way, 12 contacts, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7-7, and specifies electrical transmission requirements, including power sum alien (exogenous) crosstalk, for frequencies up to 2 000 MHz. These connectors are typically used as "category 8.2" connectors in "class II" cabling systems specified in ISO/IEC TR 11801-9901 and specified in ISO/IEC 11801-1. These connectors are intermateable and interoperable with other IEC 60603-7 series connectors, i.e. as defined in IEC 60603-7-7 and IEC 60603-7-1. These connectors are backward compatible with other IEC 60603-7 series connectors. Key words: Connectors, 8-way. Shielded Free and Fixed, Data Transmission

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-3-110:2016 This detail specification covers mechanical, electrical and environmental requirements and electrical transmission requirements for frequencies up to 3 000 MHz. These connector's transmission requirements are specifically intended for specific pairs of contacts, which are separated from the other pairs of contacts, such as by means of individual pair shields within the connector. These connectors are similar to, intermateable with, and intended to be used with the IEC 60603-7 series connectors. The IEC 60603-7 series connectors are typically used in ISO/IEC 11801 balanced cabling systems. The ISO/IEC 11801 balanced cabling systems are organized by categories according to frequency range and by basic cabling component types, e.g. according to shielding configurations. A primary common feature among the IEC 60603-7 series connectors is backward compatibility to lower frequency categories. The IEC 61076-3-110 series connectors are backward compatible with IEC 60603-7-7, IEC 60603-7-71 and IEC 60603-7-82 connectors. The IEC 61076-3-110 series connectors are not backward compatible with some IEC 60603-7 series connectors. Key words: Connectors, Free and Fixed Data Transmission, 3000 MHz

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60603-7-81:2015 Covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements, including power sum alien (exogenous) crosstalk, for frequencies up to 2 000 MHz. These connectors are typically used as "category 8.1" connectors in "class I" cabling systems specified in ISO/IEC 11801. These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in Clause 2 of IEC 60603-7. These connectors are backward compatible with other IEC 60603-7 series connectors, except IEC 60603-7-7 and IEC 60603-7-71 connectors. Key words: Connectors, Shielded, Free and Fixed Connectors

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard establishes specifications and test requirements for a high-speed two-part connector with integrated shielding function for use as a printed board connector in industrial environments. The connectors connect a backplane to printed boards.

  • Amendment
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-29-100:2015 specifies the test methods for transmission performance for M12-style connectors up to 500 MHz. It is also suitable for testing lower frequency connectors if they meet the requirements of the detail specifications and of this standard. The test methods provided herein are: - insertion loss, test 29a; - return loss, test 29b; - near-end crosstalk (NEXT) test 29c; - far-end crosstalk (FEXT), test 29d; - transverse conversion loss (TCL), test 29f; - transverse conversion transfer loss (TCTL), test 29g. For the transfer impedance (ZT) test, see IEC 60512-26-100, test 26e. For the coupling attenuation see ISO/IEC 11801. All test methods apply for two and four pair connectors. Key words: Connectors, Signal Integrity, M12 Style Connector

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-104:2014 describes circular connectors M8 screw-locking or with nominal diameter 8 mm snap-locking, typically used for industrial process measurement and control. These connectors consist of fixed and free connectors either rewireable or non-rewireable. Male connectors have round contacts of diameter 0,6 mm, diameter 0,7 mm and diameter 1,0 mm. This second edition cancels and replaces the first edition published in 2008. This edition constitutes a technical revision. The main technical changes with regard to the previous edition are as follows: - three new type ways have been added to the A-coding, including new gauges and contact diameters and - the type designation has been removed. Key words: Connectors, Circular Connectors, Data transmission

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-109:2014 describes circular connectors with IP 65/IP 67 degree of protection and suitable for data transmission with frequencies up to 500 MHz. Applications include, but are not limited to, vision systems and data acquisition. These connectors consist of fixed and free connectors, either rewireable or non-rewireable, with M 12 x 1 screw-locking. Male connectors have round contacts ∅ 0,6 mm. This standard covers two different types of connectors, denominated X and H, with different contact arrangement, not mutually interchangeable, but with common ratings and purposes. Keywords: Connectors, Circular Connectors, Data transmission

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2013-08-05: Publication allocated to cpalagi@cencenelec.eu

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-28-100:2013 specifies the test methods for transmission performance for IEC 60603-7 and IEC 61076-3 series connectors up to 1 000 MHz. It is also suitable for testing lower frequency connectors, however the test methodology specified in the detailed specification for any given connector remains the reference conformance test for that connector. The test methods provided here are: - insertion loss, - return loss, - near-end crosstalk (NEXT), - far-end crosstalk (FEXT), - transverse conversion loss (TCL) and - transverse conversion transfer loss (TCTL). For the transfer impedance (ZT) test, see IEC 60512-26-100. For the coupling attenuation, see IEC 62153-4-12. Keywords: Signal Integrity, Near-end crosstalk, Far-end crosstalk.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-24-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard method to measure the residual magnetism of a connector after exposure to a specified magnetic field.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-99-001:2012 used for the assessment of connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power, such as ISO/IEC 11801 Class D, or better, balanced cabling in support of IEEE Std 802.3at - 2009 (latest edition (PoE Plus - Power over Ethernet Plus). The object of this standard is to detail a test schedule to determine the ability of connectors to withstand a minimal number of engagements and separations when an electrical current is being passed through the connector in accordance with IEC 60512-9-3. Keywords: connectors, engaging and separating connectors

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-101:2012 describes M12 circular connectors typically used for industrial process measurement and control. These connectors consist of fixed and free connectors either rewireable or non-rewireable, with screw-locking. The connectors with glass to metal seal are fixed connectors only which consist of fixed glass to metal sealed styles with rewireable male contacts and are intermateable with corresponding free connectors according to this International Standard. Male connectors have round contacts 0,6 mm, 0,76 mm, 0,8 mm and 1,0 mm. The different codings prevent the mating of these coded male or female connectors to any other interfaces and cross-mating between the different codings. This third edition cancels and replaces the second edition published in 2008 and its corrigendum published in 2010. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - The drawings of some styles have been corrected, - A new style with maximum 17 poles, with A-coding, has been added, as new applications for the industrial process measurement and control require a high number of poles in M12 circular connectors. The existing styles and dimensions which were specified in IEC 61076-2-101 Ed.2 are further applicable for the added interface dimension of the 17 poles versions, - Removal of the type designation and ordering information, former Tables 6 and 7 have been updated accordingly and - Inclusion of the technical content of IEC PAS 61076-2-108, which will be withdrawn after publication of this International Standard. The drawings have been updated and correction to the title of Figure 9 was made. Keywords: M12 connectors, Circular connector

  • Standard
    125 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-16-21:2012 The object of this standard is to define a standard test method to assess the possibility of whisker growth by external mechanical stress on the tin and tin-alloy plated parts of a connector in its application (after wire termination, after soldering, after mounting, mated with counterpart). This standard does not cover internal stress type whisker. This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. Keywords: Whisker growth, external mechanical stress

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-4-116:2012 establishes specifications and test requirements for a high-speed two-part connector with integrated shielding function for use as a printed board connector in industrial environments. The connectors connect a backplane to printed boards. Keywords: Connector, Printed board connector.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-1-100:2012 provides a listing of the 60512 series of standards for specific tests that are created for connectors. Further it gives cross-references with the former (60)512 standards, where different test numbers were used. The connector tests as such are mainly identical with the previously published standards; minor changes may be introduced due to technical developments (e.g. other soldering temperatures in soldering tests, resulting from the introduction of lead-free soldering). The former issues were in booklets, with several related tests in one document, while the present issues are leaflets, each featuring one single test. This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision. This new edition reflects the status of publications in the IEC 60512 series as of September 1st 2011.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60352-5:2012 is applicable to solderless press-in connections for use in telecommunication equipment and in electronic devices employing similar techniques. The press-in connection consists of a termination having a suitable press-in zone which is inserted into a plated-through hole of a double-sided or multilayer printed board. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this part of IEC 60352 is to determine the suitability of press-in connections under mechanical, electrical and atmospheric conditions as specified by the manufacturer of the press-in termination and to provide a means of comparing test results when the tools used to make the connections are of different designs or manufacture. This fourth edition cancels and replaces the third edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - enhancement of Annex A and further application remarks are added; - editorial changes throughout the standard to prevent the document from being misunderstood as specification for establishing press-in connection in total; - deletion of all tables with hole dimensions. Historically the hole dimensions were constrained because of the dimensions of the wire wrap and clip connections posts. Since these connection technologies are no longer commonly used, the design requirements are no longer practical; - inclusion of additional figures and one table in 4.4.4 to define tolerance ranges for holes in test-boards and to illustrate them; - inclusion of a requirement for the thickness of the test-board in 4.4.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-27-100:2011 specifies the test methods for transmission performance for IEC 60603-7 series connectors up to 500 MHz. It is also suitable for testing lower frequency connectors if they meet the requirements of the detail specifications and of this standard. The test methods provided are: - insertion loss, - return loss, - near-end crosstalk (NEXT), - far-end crosstalk (FEXT), - transverse conversion loss (TCL) and - transverse conversion transfer loss (TCTL). For the transfer impedance (Zt) test, see IEC 60512-26-100 and for the coupling attenuation, see IEC 62153-4-12.

  • Standard
    68 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-9-2:2011 when required by the detail specification, this part of IEC 60512, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the ability of a connector to withstand elevated temperatures with electrical loading. This standard cancels and replaces Test 9b of IEC 60512-5, issued in 1992.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-7-2:2011 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the ability of a free connector on the end of a cable or wire bundle to withstand impacts it could receive when dropped onto a hard surface.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60603-7 covers 8-way unshielded free and fixed connectors, it is intended to specify the common dimensions, mechanical, electrical and environmental characteristics and tests for the family of IEC 60603-7-x connectors. These connectors are intermateable (according to IEC 61076-1 level 2) and interoperable with other IEC 60603-7 series connectors.

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-106:2011 describes circular connectors with IP40 or IP65/67 protection degree, typically used for industrial process measurement and control. These connectors consist of fixed and free connectors, either rewireable or non-rewireable, with M16 x 0,75 screw-locking. Male connectors have round contacts Ø 1,5 mm or Ø 1,0 mm.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-001:2011 This blank detail product specification is a supplementary document to the sectional product specification IEC 61076-2 and contains requirements for style, layout and content of detail product specifications for circular connectors. It should be used in conjunction with the following publications: IEC 61076-1 and IEC 61076-2 for product requirements as well as IEC 62197-1 for quality requirements. The sample pages can be used like a template when preparing a detail product specification within the scope of this document. This document is not intended to replace the templates and guidance notes of IEC, but to assist in their application. All users are reminded to adhere to relevant directives and guidelines of the IEC when preparing a standard. This second editon cancels and replaces the first edition of IEC 61076-2-001 (2001). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - This International Standard no longer includes the quality assessment procedures. As described in IEC 61076-1 and IEC 62197-1, a new document structure has been established. IEC 61076-2-001 has been revised to reflect this updated structure. - Subclause 3.2, Systems of levels has been introduced. - The subclause IEC type designation has been removed. - Clauses 4 Dimensional information and 5 Characteristics have been added. - Some clauses and test groups have been rearranged. Test group HP has been added.

  • Standard
    78 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2:2011 establishes uniform specifications and technical information for circular connectors. It should be used in conjunction with the generic specification IEC 61076-1:2006 for product requirements and with IEC 62197-1 for quality requirements as the basis for preparation of consistent detail product specifications for circular connectors. In the event of conflict between this sectional specification and the detail product specification, it is intended that the requirements of the detail product specification prevail. This second edition cancels and replaces the first edition of IEC 61076-2 (1998). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. This International Standard no longer includes the quality assessment procedures. As described in IEC 61076-1 and IEC 62197-1, a new document structure has been established. IEC 61076-2 has been revised to reflect this updated structure. Subclause 3.2, Systems of levels has been introduced. The subclause on IEC type designation has been removed. Clauses 4 Dimensional information and 5 Characteristics have been added. Some clauses and test groups have been rearranged. Test group HP has been added.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-9-3:2011 defines a standard test method to assess the mechanical and electrical operational endurance, i.e. engaging and separating cycles, of a connector in an operating mode which includes a specified electrical load. This second edition cancels and replaces Test 9c of IEC 60512-5, issued in 1992, and constitutes a technical revision. The main technical changes with regard to the previous edition are as follows: - An additional requirement to 4.1 stating that if more than one electrical circuit is wired for testing, the wiring shall be carried out in a parallel electrical circuit. - Subclauses 4.3 through 4.7 were removed and replaced by 4.2 through 4.4. This publication is to be read in conjunction with IEC 60512-1:2001 and IEC 60512-1-100:2006.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60603-7-1:2011 covers 8-way shielded free and fixed connectors. It specifies the dimensions, mechanical, electrical and environmental characteristics and tests, in relation to the shield, additional to those in IEC 60603-7. These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in IEC 60603-7. This third edition cancels and replaces the second edition, published in 2009, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - the correction, or inclusion, of technical references; - the harmonization of terminology with other parts of the IEC 60603-7 series and other referenced documents; - the modification of screen dimensions so as to include connectors on the market; - the inclusion of two new test groups (EP and FP) that provides the necessary cascading and references to other parts of the IEC 60603-7 series, and satisfies the requirements of ISO/IEC 11801 to enable correct referencing.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-17-2:2011 when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard method to assess the ability of a cable-clamping device to allow rotary movement of the cable/wire bundle without damage to the external surface of the cable/wire bundle, the cable-clamping device, the connector or the sub-assembly. This standard cancels and replaces Test 17b of IEC 60512-5, issued in 1992, and constitutes a technical revision. This publication is to be read in conjunction with  IEC 60512-1:2001 and IEC 60512-1-100:2006.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-8-2:2011 when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to determine the ability of a fixed connector to withstand a steady axial force which might occur during normal use. This standard cancels and replaces Test 8b of IEC 60512-5, issued in 1992, and constitutes a technical revision. This publication is to be read in conjunction with IEC 60512-1:2001 and IEC 60512-1-100:2006.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-9-4:2011 when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the ability of a connector to withstand stresses caused by repeated extraction and insertion of contacts during maintenance. This standard cancels and replaces Test 9d of IEC 60512-5, issued in 1992, and constitutes a technical revision. This publication is to be read in conjunction with  IEC 60512-1:2001 and IEC 60512-1-100:2006.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60512 specifies the test and measurements and the related measurement setup and reference arrangements for interoperability and backward compatibility tests for the development and qualification of 8-way, free and fixed connectors for data transmission.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60139-9:2011 relates to circular connectors for radio and associated sound equipment. This fourth edition cancels and replaces the third edition of IEC 60130-9, published in 2000, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- the scope has been amended to clarify its separation through its field of application, from IEC 61076-2-106;
- 8-pole connector styles 60130-9 IEC-22 through 60130-9 IEC-25 with screw locking have been deleted as obsolete and overlapping with some styles of IEC 61076-2-106;
- application and connections in Table 1 have been deleted because of referencing obsolete sound equipment. Titles of the dimension sheets and the clause headlines of Annex A have been amended accordingly;
- the reference to safety requirements according to IEC 60065 has been deleted.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60352-8:2011 Is applicable to compression mount connections with metallic spring contacts for use in telecommunication equipments and in other electronic devices employing similar techniques. Information on materials and data from industrial experience are included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this part of IEC 60352 is to determine the suitability of compression mount connections under specified electrical, mechanical and atmospheric conditions and to provide a means of comparing test results when the tools used to make the connectors are of different designs or manufacture.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60603-7-71:2010 covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements, including power sum alien (exogenous) crosstalk, for frequencies up to 1 000 MHz. These connectors are typically used as category 7A connectors in class FA cabling systems specified in ISO/IEC 11801. These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in Clause 2 of IEC 60603-7-1 and IEC 60603-7-7. These connectors are backward compatible with other IEC 60603-7 series connectors.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day