EN 135000:1992
(Main)Generic Specification: Travelling wave amplifier tubes
Generic Specification: Travelling wave amplifier tubes
Generic specification for travelling wave amplifier tubes.
Fachgrungspezifikation: Wanderfeld-Verstärkerröhren
Spécification générique: Tubes amplificateurs à onde progressive
Splošne specifikacije: ojačevalne elektronke na potujoče valove
General Information
Standards Content (Sample)
SLOVENSKI SIST EN 135000:2004
STANDARD
september 2004
Splošne specifikacije: ojačevalne elektronke na potujoče valove
Generic specification: travelling wave amplifier tubes
ICS 31.100 Referenčna številka
SIST EN 1
...
This May Also Interest You
IEC 62391-2:2025 applies to electric double-layer capacitors for power application. Electric double-layer capacitors for power are intended for applications that require discharge currents in the range from mA to A. The characteristics of the capacitors include such performance as relatively high capacitance and low internal resistance, which is applicable to Class 3 and Class 5 of the measurement classification specified in IEC 62391-1:2022. The object of this document is to specify preferred ratings and characteristics and to select from IEC 62391-1:2022 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this document provide specific test severities and requirements of an equal or higher performance level. The definition of power density and its calculating procedure can be found in Annex A. This edition includes the following significant technical changes with respect to the previous edition: a) the document has been completely restructured to comply with the ISO/IEC Directives, Part 2; b) introduction of a new technical categorization for the test methods; c) reorganization of the test methods have been according to these new categories; d) revision of the tables, figures and references according to changes.
- Draft27 pagesEnglish languagesale 10% offe-Library read for×1 day
- 03-Apr-2025
- 31.060.10
- CLC/TC 40XA
IEC 61557-9:2023 specifies the requirements for the insulation fault location system (IFLS) that localizes insulation faults in any part of the system in unearthed IT AC systems and unearthed IT AC systems with galvanically connected DC circuits having nominal voltages up to 1 000 V AC, as well as in unearthed IT DC systems with voltages up to 1 500 V DC, independent of the measuring principle. IEC 61557-9:2023 cancels and replaces the third edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) new terms and definitions on maximum admissible locating AC and DC currents and voltages; b) the requirements on locating current and locating voltage have been revised; c) performance requirements have been added; d) the test requirements for locating current and locating voltage have been revised; e) the structure of this document has been adapted to that of IEC 61557-1:2019; f) the limit values under Clause A.2 were adapted to fit the changed test methods in 6.2.3.
- Draft32 pagesEnglish languagesale 10% offe-Library read for×1 day
Not available
- Draft8 pagesEnglish languagesale 10% offe-Library read for×1 day
- 03-Apr-2025
- 19-Dec-2022
- 13.110
- 29.020
- 2006/42/EC
- 2014/35/EU
- M/396
- M/511
- CLC/TC 44X
IEC 62657-2:2025 specifies: – the fundamental assumptions, concepts, parameters, and procedures for wireless communication coexistence; – specifies coexistence parameters and how they are used in an application requiring wireless coexistence; – provides guidelines, requirements, and best practices for wireless communication's availability and performance in an industrial automation plant; it covers the life‑cycle of wireless communication coexistence; – helps the work of all persons involved with the relevant responsibilities to cope with the critical aspects at each phase of life-cycle of the wireless communication coexistence management in an industrial automation plant. Life-cycle aspects include: planning, design, installation, implementation, operation, maintenance, administration and training; – provides a common point of reference for wireless communication coexistence for industrial automation sites as a homogeneous guideline to help the users assess and gauge their plant efforts; – deals with the operational aspects of wireless communication coexistence regarding both the static human/tool-organization and the dynamic network self-organization. This document provides a major contribution to national and regional regulations by supporting to fulfil the requirements using coexistence management. This edition includes the following significant technical changes with respect to the previous edition: a) alignment of some definitions and specifications of coexistence parameters in order to facilitate their future inclusion in the IEC Common Data Dictionary (IEC CDD) maintained by the IEC; b) alignment of some definitions and specifications to be consistent with the new IEC 62657-3 and IEC 62657-4; c) edition 3 of this document was published in June 2022. Some comments were made in the last development stages of this document asking for explanations on how the parts of the IEC 62657 series were structured and how they were related to each other. Resolution of these comments was deferred until a next edition, which means this edition.
- Draft114 pagesEnglish languagesale 10% offe-Library read for×1 day
- 03-Apr-2025
- 25.040.40
- 33.040
- 35.100
- CLC/TC 65X
IEC 60269-1:2024 is available as IEC 60269-1:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60269-1:2024 is applicable to fuses incorporating enclosed current-limiting fuse-links with rated breaking capacities of not less than 6 kA, intended for protecting power-frequency AC circuits of nominal voltages not exceeding 1 000 V or DC circuits of nominal voltages not exceeding 1 500 V.
- Draft88 pagesEnglish languagesale 10% offe-Library read for×1 day
- 03-Apr-2025
- 29.120.50
- 2014/35/EU
- M/511
- CLC/SR 32B
IEC 63430:2025 specifies a container format for sensing data and its system requirements. This document applies to edge computing devices such as smartphones, home gateways, multimedia coordinators, etc., and cloud systems. This document describes the following technical specifications: - container format for wearable sensor data; - Schema Repository that defines the parameters and syntax of sensor data; - communication and system requirements between the edge computing device and Schema Repository.
- Draft26 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Mar-2025
- 35.240.50
- 59.080.80
- CLC/TC 100X
IEC 63563-9:2025 defines the architecture and application-level messaging for the Authentication of a Power Transmitter Product by a Power Receiver to ensure that the Power Transmitter Product is both Qi certified and the product of a registered manufacturer.
- Draft91 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Mar-2025
- 29.240.99
- 35.240.99
- CLC/TC 100X
IEC 63563-1:2025 introduces the Qi Specification, which applies to flat surface devices such as mobile phones and tablets that use up to 15 W of power
- Draft17 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Mar-2025
- 29.240.99
- 35.240.99
- CLC/TC 100X
IEC 63563-10:2025 defines MPP (Magnetic Power Profile), an extension to Qi v1.3 BPP (Baseline Power Profile). Manufacturers can use this specification to implement PTx and/or PRx that are interoperable.
- Draft164 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Mar-2025
- 29.240.99
- 35.240.99
- CLC/TC 100X
- Corrigendum3 pagesEnglish and French languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion