This document gives specific requirements for halogen free polyolefin based sheathing compounds used for halogen free communication cables with improved characteristics in the case of fire.
Compounds, described by this document, are commonly also named HFFR or HFFR-LS (halogen free, flame/fire retardant, low smoke), see also EN 50290 2 20.
It is expected to be read in conjunction with EN 50290 2 20, the product standards EN 50288 series, EN 60794 series and other applicable product standards.
Improved characteristics in the case of fire are demonstrated by specific fire tests on cables for flame/fire retardant applications (e.g. single or bunched cable fire test). Additional tests to prove the characteristics in case of fire, e.g. such as smoke emission test, might also be part of the dedicated product standard or specification.
This document describes the compound types as given in Table 1.
Table 1 — Sheathing compounds
Compound grades   Max. operating temperature   Comment
Type 1   70°C   thermoplastic standard
Type 2   90°C   thermoplastic, higher temperature
Type 3   90°C   crosslinked, higher temperature

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives specific requirements for halogen free polyolefin based sheathing compounds used for halogen free communication cables with improved characteristics in the case of fire.
Compounds, described by this document, are commonly also named HFFR or HFFR-LS (halogen free, flame/fire retardant, low smoke), see also EN 50290 2 20.
It is expected to be read in conjunction with EN 50290 2 20, the product standards EN 50288 series, EN 60794 series and other applicable product standards.
Improved characteristics in the case of fire are demonstrated by specific fire tests on cables for flame/fire retardant applications (e.g. single or bunched cable fire test). Additional tests to prove the characteristics in case of fire, e.g. such as smoke emission test, might also be part of the dedicated product standard or specification.
This document describes the compound types as given in Table 1.
Table 1 — Sheathing compounds
Compound grades   Max. operating temperature   Comment
Type 1   70°C   thermoplastic standard
Type 2   90°C   thermoplastic, higher temperature
Type 3   90°C   crosslinked, higher temperature

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61196-6-5:2020 applies to coaxial communication cables described in IEC 61196-6. It specifies the requirements for type A quad-shield CATV drop cables with screening class A++. These cables are used in CATV distribution systems, surveillance and control systems, satellite television receiving systems and bidirectional hybrid fibre coaxes (HFC). The operating frequency is up to 3000 MHz.
This part of IEC 61196 is to be used in conjunction with IEC 61196-1 and IEC 61196-6:2009.

  • Standard
    15 pages
    English language
    sale 15% off

IEC 61196-6-3:2020 is available as IEC 61196-6-3:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61196-6-3:2020 applies to coaxial communication cables described in IEC 61196-6. It specifies the requirements for 75-5 type CATV drop cables. These cables are used in CATV distribution systems, surveillance & control systems, satellite television receiving systems and as bidirectional hybrid fibre coaxes (HFC). The operating frequency is from 5 MHz to 3 000 MHz. This part of IEC 61196 is to be used in conjunction with IEC 61196-1:2005 and IEC 61196‑6:2009. It determines the layout and style with respect to the model and type. This second edition cancels and replaces the first edition, published in 2018. This edition includes the following significant technical changes with respect to the previous edition:
- designation of variants including construction details,
- consistent screening classes,
- bending test only for flexible cables.

  • Standard
    13 pages
    English language
    sale 15% off

IEC 61196-6-2:2020 is available as IEC 61196-6-2:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61196-6-2:2020 applies to coaxial communication cables described in IEC 61196-6. It specifies the requirements for 75-4 type CATV drop cables. These cables are used in CATV distribution systems, surveillance & control systems, satellite television receiving systems and as bidirectional hybrid fibre coaxes (HFC). The operating frequency is from 5 MHz to 3 000 MHz. This document is to be used in conjunction with IEC 61196-1 and IEC 61196‑6. It determines the layout and style with respect to the model and type. This second edition cancels and replaces the first edition, published in 2018. This edition includes the following significant technical changes with respect to the previous edition:
- designation of variants including construction details
- consistent screening classes,
- bending test only for flexible cables.

  • Standard
    13 pages
    English language
    sale 15% off

IEC 61196-6-4:2020 is available as IEC 61196-6-4:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61196-6-4:2020 applies to coaxial communication cables described in IEC 61196-6. It specifies the requirements for 75-7 type CATV drop cables. These cables are used in CATV distribution systems, surveillance & control systems, satellite television receiving systems and as bidirectional hybrid fibre coaxes (HFC). The operating frequency is from 5 MHz to 3 000 MHz. This part of IEC 61196 is to be used in conjunction with IEC 61196-1:2005 and IEC 61196‑6:2009. It determines the layout and style with respect to the model and type. This second edition cancels and replaces the first edition, published in 2018. This edition includes the following significant technical changes with respect to the previous edition:
- designation of variants including construction details;
- consistent screening classes;
- bending test only for flexible cables.

  • Standard
    13 pages
    English language
    sale 15% off

20200205: Corrigendum requested by ASD-STAN due to a mistake of the key in Figure 2 (symbols inverted in the original text provided to CCMC). SS

  • Corrigendum
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61196-1-119:2020 is available as IEC 61196-1-119:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61196-1-119:2020 defines the requirements to determine the average power handling capability of a coaxial cable at specified frequencies at ambient temperatures. This second edition cancels and replaces the first edition, published in 2012. This edition includes the following significant technical changes with respect to the previous edition:
- title was changed from: RF power rating to: RF average power rating;
- a test method to determine sufficient duration is included as annex
- the equations used for calculating cable coefficients and RF average power rating are corrected;
- the clauses and subclauses are rearranged.

  • Standard
    14 pages
    English language
    sale 15% off

IEC 61322:2020 applies to installed dose equivalent rate meters, warning assemblies and monitors, as defined below. It covers equipment intended to measure neutron radiation in dose equivalent rates in the energy region between thermal and 20 MeV for the purposes of radiation protection.
Assemblies of this type are commonly defined as area radiation monitors. They are normally employed to determine continuously the radiological situation in working areas in which the radiation field may change with time, for example, nuclear power plants, particle accelerators, high-activity laboratories, fuel reprocessing plants, etc., and provide alarms when the radiation field goes outside predetermined limits.
The assemblies considered in this document comprise at least:
a detector assembly, which may, for example, consist of a detector probe (for thermal neutrons such as BF3 proportional counter, 3He proportional counter, 6LiI(Tl) scintillation detector, etc.) and a moderating and absorbing medium surrounding the detector;
a processing assembly, which may be fitted into a centralized panel, which, in the case of warning assemblies and monitors, provides signal outputs and contacts capable of activating alarm or other trip circuits;
alternatively, the case when all the processing electronics are placed within the detection unit (so called "smart blocks") may be considered. In this case the functions of the processing assembly will be composed of only the indication, the providing signal outputs and contacts.  
This second edition cancels and replaces the first edition published in 1994This edition includes the following significant technical changes with respect to the previous edition:
this document has been updated to take account of the requirements of the relevant IEC standards, IEC 60532:2010 and IEC 61005:2014.

  • Standard
    107 pages
    English and French language
    sale 15% off

This document specifies the required characteristics of a coaxial cable, -50 °C, type WN, for use in aircraft electrical systems at operating temperature between  -55 °C and 200 °C and especially for high frequency up to 6 GHz.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61935-1:2019 specifies reference measurement procedures for cabling parameters and the requirements for field tester accuracy to measure cabling parameters identified in ISO/IEC 11801. References in this standard to ISO/IEC 11801 mean ISO/IEC 11801 or equivalent cabling standards.
This International Standard applies when the cable assemblies are constructed of cables complying with the IEC 61156 family of standards, and connecting hardware as specified in the IEC 60603-7 family of standards or IEC 61076-3-104, IEC 61076-3-110, IEC 61076-2-101 and IEC 61076-2-109. Where cables and/or connectors do not comply with these standards, then additional tests may be required. This edition includes the following significant technical changes with respect to the previous edition:
a) the upper frequency goes up to 2 000 MHz;
b) it introduces a new level of field tester (level VI to 2 000 MHz);
c) error models and requirements for level VI testers are improved and updated.

  • Standard
    255 pages
    English and French language
    sale 15% off

IEC 61935-1-1:2019 specifies additional reference measurement procedures for level V field testers, transverse conversion loss (TCL) and equal level transverse conversion transfer loss (ELTCTL). The requirements for field tester accuracy to measure these parameters according to the requirements of ISO/IEC 11801-1 are specified in this document.

  • Standard
    26 pages
    English and French language
    sale 15% off

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to coaxial indoor drop cables for analogue and digital signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728 series and with EN 50173 and EN 50174 series.
Cables according to this standard are designed for an operating temperature range from -40 °C and +70 °C  and at frequencies between 5 MHz and 6 000 MHz.
The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, and environmental and fire performance of the cables.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to coaxial indoor drop cables for analogue and digital signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with the EN 60728 series and with the EN 50173 and EN 50174 series.  
Cables according to this standard are designed for an operating temperature range from -40 °C and +70 °C  and at frequencies between 5 MHz and 3 000 MHz.
The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, and environmental and fire performance of the cables.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to distribution and trunk cables for analogue and digital signal transmission e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728 series and with the EN 50173 and EN 50174 series.
Cables according to this standard are designed for an operating temperature range from -40 °C and +70 °C  and at frequencies between 5 MHz and 1 000 MHz.
The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, environmental and fire performance of the cables.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to coaxial indoor drop cables for analogue and digital signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with the EN 60728 series and with EN 50173 and EN 50174 series.
Cables according to this standard are designed for an operating temperature range from -40 °C and +70 °C  and at frequencies between 5 MHz and 1 000 MHz.
The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, and environmental and fire performance of the cables.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60966 specifies requirements for radio frequency coaxial cable assemblies
operating in the transverse electromagnetic mode (TEM) and establishes general
requirements for testing the electrical, mechanical and environmental properties of radio
frequency coaxial cable assemblies composed of cables and connectors. Additional
requirements relating to specific families of cable assemblies are given in the relevant
sectional specifications.
The design of the cables and connectors used will preferably conform to the applicable parts
of IEC 61196 and IEC 61169 respectively.
NOTE 1 This document does not include tests which are normally performed on the cables and connectors
separately. These tests are described in IEC 61196-1 (all parts) and IEC 61169-1 respectively.
NOTE 2 Wherever possible, cables and connectors used in cable assemblies, even if they are not described in
the IEC 61196 or IEC 61169 series, are tested separately according to the tests given in the relevant generic
specification.
NOTE 3 Where additional protection is applied to a cable assembly, the mechanical and environmental tests
described in this document are applicable.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to coaxial outdoor drop cables for analogue and digital signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728 series and with the EN 50173 and EN 50174 series.
Cables according to this standard are designed for an operating temperature range from -40 °C and +70 °C  and at frequencies between 5 MHz and 3 000 MHz.
The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, and environmental and fire performance of the cables.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to distribution and trunk cables for analogue and digital signal transmission e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728 series and with the EN 50173 and EN 50174 series.
Cables according to this standard are designed for an operating temperature range from -40 °C and +70 °C  and at frequencies between 5 MHz and 2 000 MHz.
The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, environmental and fire performance of the cables.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to coaxial outdoor drop cables for analogue and digital signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728 series and with the EN 50173 and EN 50174 series.
Cables according to this standard are designed for an operating temperature range from -40 °C and +70 °C  and at frequencies between 5 MHz and 1 000 MHz.
The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, and environmental and fire performance of the cables.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers coaxial cables for use in analogue and digital systems. This standard should be used in conjunction with EN 50290 1 1.
Coaxial cables covered by this standard operate in transverse electromagnetic mode (TEM) and are suitable for use in a wide range of digital and analogue applications including CATV, radio frequency systems, instrumentation, broadcasting, telecommunications and data network systems. Various constructions and materials provide for indoor and outdoor applications, including underground and overhead installations, and other environmental protection characteristics.
Generally, cables are designed for use in 50 Ohm and 75 Ohm characteristic impedance systems, although other types (e.g. 93/95 Ohm) are also covered.
Coaxial cables defined by this standard may be incorporated into hybrid cable constructions with optical fibre or multi-element cable components.
All cables covered by this standard may be subjected to voltages greater than 50 V AC or 75 V DC according to the relevant sectional or detail specification. However, these cables are not intended for direct connection to the mains electricity supply or other low impedance sources.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60966-1:2019 is available as IEC 60966-1:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60966-1:2019 specifies requirements for radio frequency coaxial cable assemblies operating in the transverse electromagnetic mode (TEM) and establishes general requirements for testing the electrical, mechanical and environmental properties of radio frequency coaxial cable assemblies composed of cables and connectors. Additional requirements relating to specific families of cable assemblies are given in the relevant sectional specifications. This third edition cancels and replaces the second edition published in 1999. This edition includes the following significant technical changes with respect to the previous edition: a) measurement method for screening effectiveness was cancelled; b) give references to relevant test procedures for transfer impedance and screening attenuation

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 50117 which is a sectional specification applies to coaxial indoor drop cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728-1, EN 60728-1-1, EN 60728-101, EN 60728-10, EN 50173-1 and EN 50173-4. This includes also the transmission of BCT signals provided by a CATV, MATV or SMATV cable network. The purpose of this document is to specify the applicable test methods and requirements for the electrical, mechanical and environmental characteristics and for fire performance of the cables.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 50117 which is a sectional specification applies to coaxial indoor drop cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728-1, EN 60728-1-1, EN 60728-101, EN 60728-10, EN 50173-1 and EN 50173-4. This includes also the transmission of BCT signals provided by a CATV, MATV or SMATV cable network. The purpose of this document is to specify the applicable test methods and requirements for the electrical, mechanical and environmental characteristics and for fire performance of the cables.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 50117 which is a sectional specification applies to coaxial distribution and trunk cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728-1, EN 60728-1-1, EN 60728-101, EN 60728-10, EN 50173-1 and EN 50173-4. This includes also the transmission of BCT signals provided by a CATV, MATV or SMATV cable network. The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical and environmental characteristics and for fire performance of the cables.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers coaxial cables for use in analogue and digital systems. This document should be used in conjunction with EN 50290-1-1. Coaxial cables covered by this document operate in transverse electromagnetic mode (TEM) and are suitable for use in a wide range of digital and analogue applications including CATV, radio frequency systems, instrumentation, broadcasting, telecommunications and data network systems. Various constructions and materials provide for indoor and outdoor applications, including underground and overhead installations, and other environmental protection characteristics. Generally, cables are designed for use in 50 Ohm and 75 Ohm characteristic impedance systems, although other types (e.g. 93/95 Ohm) are also covered. Coaxial cables defined by this document may be incorporated into hybrid cable constructions with optical fibre or multi-element cable components. All cables covered by this document may be subjected to voltages greater than 50 V AC or 75 V DC according to the relevant sectional or detail specification. However, these cables are not intended for direct connection to the mains electricity supply or other low impedance sources.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 50117 which is a sectional specification applies to coaxial outdoor drop cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728-1, EN 60728-1-1, EN 60728-101, EN 60728-10, EN 50173-1 and EN 50173-4. This includes also the transmission of BCT signals provided by a CATV, MATV or SMATV cable network. The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical and environmental characteristics and for fire performance of the cables.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 50117 which is a sectional specification applies to coaxial outdoor drop cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728-1, EN 60728-1-1, EN 60728-101, EN 60728-10, EN 50173-1 and EN 50173-4. This includes also the transmission of BCT signals provided by a CATV, MATV or SMATV cable network. The purpose of this document is to specify the applicable test methods and requirements for the electrical, mechanical and environmental characteristics and for fire performance of the cables.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 50117 which is a sectional specification applies to coaxial indoor drop cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728-1, EN 60728-1-1, EN 60728-101, EN 60728-10, EN 50173-1 and EN 50173-4. This includes also the transmission of BCT signals provided by a CATV, MATV or SMATV cable network. These cables are suitable to implement the network type Case D as given in subclause 6.6 of EN 60728-1-1:2014. The purpose of this document is to specify the applicable test methods and requirements for the electrical, mechanical and environmental characteristics and for fire performance of the cables.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 50117 which is a sectional specification applies to coaxial distribution and trunk cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728-1, EN 60728-1-1, EN 60728-101, EN 60728-10, EN 50173-1 and EN 50173-4. This includes also the transmission of BCT signals provided by a CATV, MATV or SMATV cable network. The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical and environmental characteristics and for fire performance of the cables.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60966-1:2019 is available as IEC 60966-1:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60966-1:2019 specifies requirements for radio frequency coaxial cable assemblies operating in the transverse electromagnetic mode (TEM) and establishes general requirements for testing the electrical, mechanical and environmental properties of radio frequency coaxial cable assemblies composed of cables and connectors. Additional requirements relating to specific families of cable assemblies are given in the relevant sectional specifications. This third edition cancels and replaces the second edition published in 1999. This edition includes the following significant technical changes with respect to the previous edition:
a) measurement method for screening effectiveness was cancelled;
b) give references to relevant test procedures for transfer impedance and screening attenuation

  • Standard
    107 pages
    English and French language
    sale 15% off

IEC 61935-1-2:2018 specifies additional reference measurement procedures for measurement of resistance unbalance with field test instrumentation, and the requirements for field tester accuracy to measure resistance unbalance according to the requirements of ISO/IEC 11801-1.

  • Standard
    20 pages
    English and French language
    sale 15% off

This European Standard specifies the required characteristics of a light weight coaxial cable, 50 Ω, type KX
for use in aircraft electrical systems at operating temperature between − 55 °C and 200 °C and specially for
high frequency up to 6 GHz. Nevertheless, if needed, − 65 °C is also acceptable as shown by rapid change of
temperature test.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62153-4-17:2018 applies to the testing of the reduction factor of multi-element metallic cables used in analogue and digital communication and control. The described method is generally applicable to all screened metallic cables.
The reduction factor describes the screening effectiveness of a cable screen at frequencies below 1 kHz with a ratio of voltages describing the screened and unscreened situation. During the measurement, the cable under test is connected to a specific current loop arrangement.

  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 62153-4-8:2018 is also available as IEC 62153-4-8:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62153-4-8:2018 specifies a test method for determining the capacitive coupling admittance, the capacitive coupling impedance and the coupling capacitance by the use of a triaxial set-up in a similar manner as for the measurement of the transfer impedance (see IEC 62153-4-3). Most cables have negligible capacitive coupling; however, in the case of cables with loose single-braids, the coupling through the holes in the screen shall be determined by the measurement of the capacitive coupling admittance. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) use of the triaxial set-up in a similar manner as for the measurement of the transfer impedance (see IEC 62153-4-3),
b) use of vector network analyser instead of capacitance bridge or pulse generator.

  • Standard
    28 pages
    English and French language
    sale 15% off

IEC 62153-4-9:2018 is also available as IEC 62153-4-9:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62153-4-9:2018 applies to metallic communication cables. It specifies a test method for determining the coupling attenuation aC of screened balanced cables. Due to the concentric outer tube, measurements are independent of irregularities on the circumference and external electromagnetic fields. A wide dynamic and frequency range can be applied to test even super screened cables with normal instrumentation from low frequencies up to the limit of defined transversal waves in the outer circuit at approximately 4 GHz. However, when using a balun, the upper frequency is limited by the properties of the balun. Measurements can be performed with standard tube procedure (respectively with standard test head) according to IEC 62153-4-4 or with open tube (open test head) procedure.
The procedure described herein to measure the coupling attenuation aC is based on the procedure to measure the screening attenuation aS according to IEC 62153-4-4. This second edition cancels and replaces the first edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
– two test procedures, open head and standard head procedure;
– measuring with balun or with multiport respectively mixed mode VNA;
– extension of frequency range up to and above 2 GHz.

  • Standard
    56 pages
    English and French language
    sale 15% off

IEC 61196-6-3:2018(E) applies to coaxial communication cables described in IEC 61196-6. It specifies the requirements for 75-5 type CATV drop cables. These cables are used in CATV distribution systems, surveillance and control systems, satellite television receiving systems and as bidirectional hybrid fibre coax (HFC). The operating frequency is from 5 MHz to 3 000 MHz.
This part of IEC 61196 is to be used in conjunction with IEC 61196-1:2005 and IEC 61196 6:2009. It determines the layout and style with respect to the model and type.

  • Standard
    12 pages
    English language
    sale 15% off

IEC 61196-6-2:2018(E) applies to coaxial communication cables described in IEC 61196-6. It specifies the requirements for 75-4 type CATV drop cables. These cables are used in CATV distribution systems, surveillance and control systems, satellite television receiving systems and as bidirectional hybrid fibre coax (HFC). The operating frequency is from 5 MHz to 3 000 MHz.
This part of IEC 61196 is to be used in conjunction with IEC 61196-1:2005 and IEC 61196 6:2009. It determines the layout and style with respect to the model and type.

  • Standard
    12 pages
    English language
    sale 15% off

IEC 61196-6-4:2018(E) applies to coaxial communication cables described in IEC 61196-6. It specifies the requirements for 75-7 type CATV drop cables. These cables are used in CATV distribution systems, surveillance and control systems, satellite television receiving systems and as bidirectional hybrid fibre coax (HFC). The operating frequency is from 5 MHz to 3 000 MHz.
This part of IEC 61196 is to be used in conjunction with IEC 61196-1:2005 and IEC 61196 6:2009. It determines the layout and style with respect to the model and type.

  • Standard
    13 pages
    English language
    sale 15% off

IEC 61196-1-113:2018(E) applies to coaxial communications cables. It specifies a test method for determining the attenuation constant of coaxial cables for use in communications systems. The test is applicable preferably at frequencies ≥ 5 MHz, but also for lower frequencies if the magnitude of the complex characteristic impedance is approximately equal to the nominal characteristic impedance of the specimen or if a form fitting function is applied.
This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition: diverse form fitting equations are provided.

  • Standard
    10 pages
    English language
    sale 15% off

IEC 61196-5:2018(E), which is a sectional specification, applies to coaxial cables for analogue and digital one- and two-way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with IEC 60728-1, IEC 60728-1-1, IEC 60728-101, IEC 60728-10, ISO/IEC 11801-1 and ISO/IEC 11801-4. This includes also the transmission of BCT signals provided by a CATV, MATV or SMATV cable networks.
This document specifies the test procedures and requirements for trunk and distribution cables for temperatures between −40 °C and +65 °C and in the frequency range of 5 MHz to 2 000 MHz.
This third edition cancels and replaces the second edition published in 2012. This edition constitutes a technical revision.
This edition includes the following significant technical change with respect to the previous edition:
a) 1 Scope: revised, frequency range extended to 2 000 MHz;
b) 4.3 Dielectric: life expectancy of the dielectric is proved by oxidative induction time (OIT) test before and after ageing according to IEC 60811-410;
c) Annex A: Table A.1, Cable types added.

  • Standard