EN 60044-2:1999
(Main)Instrument transformers - Part 2: Inductive voltage transformers
- BACK
- 15-Mar-1999
- 31-Dec-2001
- 29.180
- 89/336/EEC
- CLC/TC 38
Instrument transformers - Part 2: Inductive voltage transformers
Applies to new inductive voltage transformers for use with electrical measuring instruments and electrical protective devices at frequencies from 15 to 100 Hz. This standard relates basically to transformers with separate windings, but also to autotransformers. It replaces HD 554(92) plus Amendments 1 and 2 only for inductive voltage transformers. HD 554 remains in force for capacitive voltage transformers.
Messwandler - Teil 2: Induktive Spannungswandler
Transformateurs de mesure - Partie 2: Transformateurs inductifs de tension
S'applique aux transformateurs inductifs neufs destinées à être utilisés avec des appareils de mesure électriques et des dispositifs électriques de protection, de fréquence comprise entre 15 Hz et 100 Hz. La norme s'applique principalement aux transformateurs à enroulements séparés, mais aussi aux autotransformateurs. Elle annule et remplace la deuxième édition de la HD 554 et les amendements 1 et 2, pour les transformateurs inductifs de tension. La HD 554 reste encore en viguer pour les transformateurs condensateurs de tension.
Merilni transformatorji - 2. del: Induktivni napetostnik (IEC 60044-2:1997, spremenjen)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-2001
1DGRPHãþD
SIST HD 554 S1:1995
Merilni transformatorji - 2. del: Induktivni napetostnik (IEC 60044-2:1997,
spremenjen)
Instrument transformers -- Part 2: Inductive voltage transformers
Messwandler -- Teil 2: Induktive Spannungswandler
Transformateurs de mesure -- Partie 2: Transformateurs inductifs de tension
Ta slovenski standard je istoveten z: EN 60044-2:1999
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
SIST EN 6004
...
This May Also Interest You
IEC 61558-2-5:2024 is available as IEC 61558-2-5:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61558-2-5:2024 deals with the safety of shaver transformers, power supply units incorporating a shaver transformer, and shaver supply units. Shaver transformers incorporating electronic circuits are also covered by this document. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) adjustment of structure and references in accordance with IEC 61558-1:2017; b) new symbol for power supply unit with linearly regulated output voltage. It has the status of a group safety publication in accordance with IEC Guide 104.
- Draft18 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Mar-2025
- 29.180
- 2014/35/EU
- M/511
- CLC/SR 96
IEC 61558-2-12:2024 is available as IEC 61558-2-12:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61558-2-12:2024 deals with the safety of constant voltage transformers for general applications and power supply units for constant voltage for general applications. Constant voltage transformers incorporating electronic circuits are also covered by this document. This third edition cancels and replaces the second edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) adjustment of structure and references in accordance with IEC 61558-1:2017; b) description of constructions moved to IEC 61558-1:2017; c) new symbol for power supply unit with linearly regulated output voltage. It has the status of a group safety publication in accordance with IEC Guide 104.
- Draft20 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Mar-2025
- 29.180
- 2014/35/EU
- M/511
- CLC/SR 96
IEC 61558-2-20:2022 is available as IEC 61558-2-20:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61558-2-20:2022 deals with the safety of small reactors for general applications. Small reactors incorporating electronic circuits are also covered by this document. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - adjustment of structure and references in accordance with IEC 61558-1:2017. - additional Annex AA with references for characteristic parameter measurements. - additional Annex BB for associated reactors with frequencies above 500 Hz. - additional Annex CC for partial discharge. It has the status of a group safety publication in accordance with IEC Guide 104.
- Draft20 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Mar-2025
- 29.180
- 2014/35/EU
- M/511
- CLC/SR 96
IEC 61558-2-23:2024 is available as IEC 61558-2-23:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61558-2-23:2024 deals with the safety of transformers for construction sites and power supply units incorporating transformers for construction sites. Transformers incorporating electronic circuits are also covered by this document. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) adjustment of structure and references in accordance with IEC 61558-1:2017; b) new symbol for power supply units with linearly regulated output voltage. It has the status of a group safety publication in accordance with IEC Guide 104.
- Draft20 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Mar-2025
- 29.180
- 2014/35/EU
- M/511
- CLC/SR 96
This part of IEC 61558 deals with safety of isolating transformers for medical IT systems for the supply of medical locations. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers isolating transformers for medical IT systems for the supply of medical locations. This document is applicable to isolating transformers, single-phase or three-phase, air-cooled (natural or forced) dry-type transformers for the supply of medical IT system for group 2 medical locations, designed to be permanently connected to the fixed wiring and intended to form the medical IT system on the secondary side. The windings can be encapsulated or non encapsulated. NOTE 2 IT systems are defined in IEC 60364-1. The installation rules for medical IT system for group 2 medical locations are covered by IEC 60364-7-710. Transformers covered by this document are intended for medical IT systems for the supply of medical locations. All other transformers or equipments connected downstream from the transformer are not covered by this document. The rated supply voltage does not exceed 1 000 V AC. The rated supply frequency and internal operational frequency do not exceed 500 Hz. The rated output does not be less than 0,5 kVA and does not exceed 10 kVA for single-phase and three-phase transformers for medical IT system for group 2 medical locations. This document may be applicable to isolating transformers intended to supply other medical installations that are not group 2 medical locations without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. NOTE 3 Transformers intended to supply distribution networks other than medical IT systems are not included in the scope. The no-load output voltage and the rated output voltage does not exceed 250 V AC for single-phase or three-phase transformer (phase-to-phase voltage). This document does not cover power supply units and is not intended to be used in conjunction with IEC 61558-2-16 for switch mode power supply units. This document is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers. Transformers covered by this document are used in applications where double or reinforced insulation between circuits is required by the installation rules or by the appliance specification. NOTE National installation rules of some countries have different or additional requirements listed in Annex C of IEC 60364-7-710:2021. Attention is drawn 193 to the following: - for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.); - measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing; - the different conditions for transportation, storage, and operation of the transformers; - additional requirements in accordance with other appropriate standards and national rules may be applicable to transformers intended for use in special environments. This GROUP SAFETY PUBLICATION focusing on SAFETY guidance is primarily intended to be used as a PRODUCT SAFETY STANDARD for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products similar to those mentioned in the scope of this GROUP SAFETY PUBLICATION, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51. One of the RESPONSIBILITIES of a TC is, wherever applicable, to make use of BSPs and/or GSPs in the preparation of its publications.
- Draft20 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Mar-2025
- 03-Jan-2023
- 29.180
- 2014/35/EU
- M/511
- CLC/SR 96
IEC 61558-2-8:2024 is available as IEC 61558-2-8:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61558-2-8:2024 deals with the safety of bell and chime transformers and power supply units incorporating bell and chime transformers. Transformers incorporating electronic circuits are also covered by this document. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) adjustment of structure and references in accordance with IEC 61558-1:2017; b) new symbol for power supply unit with linearly regulated output voltage. It has the status of a group safety publication in accordance with IEC Guide 104.
- Draft17 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Mar-2025
- 29.180
- 2014/35/EU
- M/511
- CLC/SR 96
This part of IEC 61558 deals with the safety of variable transformers for general applications and power supply units incorporating variable transformers for general applications. Variable transformers incorporating electronic circuits are also covered by this document. NOTE 1 Safety includes electrical, thermal, mechanical and chemical aspects. Unless otherwise specified, from here onward, the term transformer covers variable transformers for general applications and power supply units incorporating variable transformers for general applications. For power supply units (linear) this document is applicable. For switch mode power supply units, IEC 61558-2-16 is applicable together with this document. Where two requirements are in conflict, the most severe take precedence. This document does not apply to transformers covered by IEC 60076-11. This document is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated variable dry-type transformers. - variable auto-transformers; - variable separating transformers; - variable isolating transformers; - variable safety isolating transformers. The windings can be encapsulated or non-encapsulated. The rated supply voltage does not exceed 1 000 V AC and the rated supply frequency and the internal operational frequencies do not exceed 500 Hz. The rated output does not exceed: - 40 kVA for single-phase variable auto-transformers; - 200 kVA for poly-phase variable auto-transformers; - 1 kVA for single-phase variable separating transformers; - 5 kVA for poly-phase variable separating transformers; - 25 kVA for single-phase variable isolating transformers; - 40 kVA for poly-phase variable isolating transformers; - 10 kVA for single-phase variable safety isolating transformers; - 16 kVA for poly-phase variable safety isolating transformers. This document is applicable to variable transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. NOTE 2 Transformers intended to supply distribution networks are not included in the scope. [...]
- Draft20 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Mar-2025
- 29.180
- 2014/35/EU
- M/511
- CLC/SR 96
This part of IEC 61558 deals with the safety of auto-transformers for general applications and power supply units incorporating auto-transformers for general applications. Transformers incorporating electronic circuits are also covered by this document. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers auto-transformers for general applications and power supply units incorporating auto-transformers for general applications. For power supply units (linear) this document is applicable. For switch mode power supply units IEC 61558-2-16 is applicable. This document is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated dry- type transformers. The windings may be encapsulated or non-encapsulated. The rated supply voltage does not exceed 1 000 V AC, and the rated supply frequency and the internal operating frequencies do not exceed 500 Hz. The core power does not exceed: - 2 kVA for single-phase transformers; - 10 kVA for polyphase transformers. The rated output does not exceed: - 40 kVA for single-phase transformers; - 200 kVA for polyphase transformers. This document is applicable to transformers without limitation of the core power and the rated output both being subject to an agreement between the purchaser and the manufacturer. Where applicable, the no-load output voltage or the rated output voltage does not exceed 1 000 V AC or 1 415 V ripple-free DC. For independent transformers, the no-load output voltage and the rated output voltage is not less than 50 V AC or 120 V ripple-free DC. This document is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers. NOTE 2 Transformers covered by this document are used only in applications where no insulation between circuits is required by the installation rules or by the end product standard. Attention is drawn to the following: - for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.); - measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing; - the different conditions for transportation, storage, and operation of the transformers; - additional requirements in accordance with other appropriate standards and national rules may be applicable to transformers intended for use in special environments. Future technological development of transformers may necessitate a need to increase the 202 upper limit of the frequencies. Until then this document may be used as a guidance document. This GROUP SAFETY PUBLICATION focusing on SAFETY guidance is primarily intended to be used as a PRODUCT SAFETY STANDARD for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products similar to those mentioned in the scope of this GROUP SAFETY PUBLICATION, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51. One of the RESPONSIBILITIES of a TC is, wherever applicable, to make use of BSPs and/or GSPs in the preparation of its publications.
- Draft15 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Mar-2025
- 29.180
- 2014/35/EU
- M/511
- CLC/SR 96
IEC 61558-2-9:2024 is available as IEC 61558-2-9:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61558-2-9:2024 deals with the safety of transformers for class III handlamps and power supply units incorporating transformers for class III handlamps. Transformers incorporating electronic circuits are also covered by this document. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) adjustment of structure and references in accordance with IEC 61558-1:2017; b) addition of a new symbol for power supply unit with linearly regulated output voltage; c) document is not only valid for transformers for tungsten filament handlamps. It has the status of a group safety publication in accordance with IEC Guide 104.
- Draft16 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Mar-2025
- 29.180
- 2014/35/EU
- M/511
- CLC/SR 96
This part of IEC 61558 deals with the safety of control transformers and power supply units incorporating control transformers. Transformers incorporating electronic circuits are also covered by this document. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers control transformers and power supply units incorporating control transformers. For power supply units (linear) this document is applicable. For switch mode power supply units IEC 61558-2-16 is applicable together with this document. Where two requirements are in conflict, the most severe take precedence. This document does not apply to transformers covered by IEC 60076-11. This document is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated dry- type transformers. The windings can be encapsulated or non-encapsulated. The rated supply voltage does not exceed 1 000 V AC and the rated supply frequency and the internal operating frequencies do not exceed 500 Hz. The rated thermal output does not exceed: - 25 kVA for single-phase transformers, - 40 kVA for polyphase transformers; This document is applicable to transformers without limitation of the rated thermal output, subject to an agreement between the purchaser and the manufacturer. NOTE 2 Transformers intended to supply distribution networks are not included in the scope. The no-load output voltage or the rated output voltage does not exceed 1 000 V AC or 1 415 V ripple-free DC. For independent transformers the no-load output voltage and / or the rated output voltage is not less than 50 V AC or 120 V ripple-free DC. This document is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers. NOTE 3 Transformers covered by this document are only used in applications where double or reinforced insulation between circuits is not required by the installation rules or by the end product standard. NOTE 4 Normally the control transformers are intended to be used with equipment to provide voltages different from the supply voltage for the functional requirements of the equipment. The protection against electric shock may be provided or completed by other features of the equipment, such as the body. Parts of output circuits may be connected to the input circuits or to protective earthing. Attention is drawn to the following: - for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.); - measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing; - the different conditions for transportation, storage, and operation of the transformers; - additional requirements in accordance with other appropriate standards and national rules may be applicable to transformers intended for use in special environments. Future technological development of transformers may necessitate a need to increase the upper limit of the frequencies. Until then this document may be used as a guidance document. This GROUP SAFETY PUBLICATION focusing on SAFETY guidance is primarily intended to be used as a PRODUCT SAFETY STANDARD for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products similar to those mentioned in the scope of this GROUP SAFETY PUBLICATION, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51. One of the RESPONSIBILITIES of a TC is, wherever applicable, to make use of BSPs and/or GSPs in the preparation of its publications.
- Draft16 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Mar-2025
- 29.180
- 2014/35/EU
- M/511
- CLC/SR 96
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.