Electromechanical elementary relays of assessed quality - Part 10: Sectional specification - Relays for industrial application

Is based on the basic relay standard EN 61810-1 as well as on the generic specification EN 61811-1 and selects from EN 61810-7 the appropriate test and measurement procedures to be used in detail specifications derived from this specification

Elektromechanische Elementarrelais mit bewerteter Qualität - Teil 10: Rahmenspezifikation - Relais für industrielle Anwendungen

Relais élémentaires électromécaniques soumis au régime d'assurance de la qualité - Partie 10: Spécification intermédiaire - Relais pour applications industrielles

En anglais seulement

Electromechanical elementary relays of assessed quality - Part 10: Sectional specification - Relays for industrial application

General Information

Status
Withdrawn
Publication Date
17-Feb-2003
Withdrawal Date
31-Jan-2006
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
04-Mar-2018
Completion Date
04-Mar-2018

Relations

Buy Standard

Standard
EN 61811-10:2003
English language
24 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI SIST EN 61811-10:2003

STANDARD
september 2003
Electromechanical elementary relays of assessed quality - Part 10: Sectional
specification - Relays for industrial application
ICS 29.120.70 Referenčna številka
SIST EN 61811-10:2003(en)
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD EN 61811-10
NORME EUROPÉENNE
EUROPÄISCHE NORM February 2003

ICS 29.120.70


English version


Electromechanical elementary relays of assessed quality
Part 10: Sectional specification –
Relays for industrial application
(IEC 61811-10:2002)


Relais élémentaires électromécaniques Elektromechanische Elementarrelais
soumis au régime d'assurance mit bewerteter Qualität
de la qualité Teil 10: Rahmenspezifikation –
Partie 10: Spécification intermédiaire - Relais für industrielle Anwendungen
Relais pour applications industrielles (IEC 61811-10:2002)
(CEI 61811-10:2002)






This European Standard was approved by CENELEC on 2003-02-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta,
Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 61811-10:2003 E

---------------------- Page: 2 ----------------------

EN 61811-10:2003 - 2 -
Foreword

The text of document 94/168/FDIS, future edition 1 of IEC 61811-10, prepared by IEC TC 94,
All-or-nothing electrical relays, was submitted to the IEC-CENELEC parallel vote and was approved by
CENELEC as EN 61811-10 on 2003-02-01.

The following dates were fixed:

– latest date by which the EN has to be implemented
 at national level by publication of an identical

 national standard or by endorsement (dop) 2003-11-01
– latest date by which the national standards conflicting
 with the EN have to be withdrawn (dow) 2006-02-01

Annexes designated "normative" are part of the body of the standard.
Annexes designated "informative" are given for information only.
In this standard, annex ZA is normative and annexes A and B are informative.
Annex ZA has been added by CENELEC.
__________

Endorsement notice

The text of the International Standard IEC 61811-10:2002 was approved by CENELEC as a European
Standard without any modification.
__________

---------------------- Page: 3 ----------------------

- 3 - EN 61811-10:2003
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amendments to or revisions of any
of these publications apply to this European Standard only when incorporated in it by amendment or
revision. For undated references the latest edition of the publication referred to applies (including
amendments).
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
Publication Year Title EN/HD Year
IEC 60062 1992 Marking codes for resistors and EN 60062 1993
capacitors A11 2001

IEC 60255-23 1994 Electrical relays EN 60255-23 1996
Part 23: Contact performance

IEC 60410 1973 Sampling plans and procedures for - -
inspection by attributes

IEC 61709 1996 Electronic components - Reliability - EN 61709 1998
Reference conditions for failure rates
and stress models for conversion

IEC 61810-1 1998 Electromechanical non-specified time EN 61810-1 1998
all-or-nothing relays
Part 1: General requirements

IEC 61810-5 1998 Part 5: In
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.