Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements

This European Standard covers dry type transformers from 100 kVA to 3 150 kVA intended for operation in three phases distribution networks, for indoor continuous service, 50 Hz, natural cooling, with two windings: − a primary (high voltage) winding with a highest voltage for equipment of 3,6 kV to 36 kV; − a secondary (low voltage) winding with a highest voltage for equipment not exceeding 1,1 kV. For outdoor application, special design or enclosure (enclosure with adapted IP and IK degrees protections) should be requested. NOTE 1 This European Standard may be applied, as a whole or in part to transformers having windings with more than one rated voltage. In this case the rated power for each coupling ratio should be specified by the purchaser. NOTE 2 For dry type transformers installed in power generating plants, additional requirements, not covered by this European Standard, and alternative requirements may be specified. NOTE 3 For dry type transformers dedicated to wind turbines applications additive requirements are specified in EN 60076-16. The object of this European Standard is to lay down requirements related to electrical characteristics, dimensions and designs of three phases distribution dry type transformers. These transformers should be in accordance with EN 60076-11 for general requirements.

Drehstrom-Trocken-Verteilungstransformatoren, 50 Hz, 100 kVA bis 3 150 kVA, mit einer höchsten Spannung für Betriebsmittel kleiner oder gleich 36 kV - Teil 1: Allgemeine Anforderungen

Transformateurs triphasés de distribution de type sec, 50 Hz, de 100 kVA à 3 150 kVA, avec une tension la plus élevée pour le matériel ne dépassant pas 36 kV - Partie 1: Prescriptions générales

Trifazni suhi distribucijski transformatorji, 50 Hz, od 100 do 3150 kVA, za napetosti, ki ne presegajo 36 kV - 1. del: Splošne zahteve in zahteve za suhi tip transformatorjev za napetosti, ki ne presegajo 36 kV

Ta evropski standard zajema suhi tip transformatorjev med 100 kVA in 3 150 kVA, namenjen za obratovanje v trifaznih distribucijskih omrežjih za neprekinjeno delovanje v zaprtih prostorih, 50 Hz, z naravnim hlajenjem in dvema navitjema: - primarno (visokonapetostno) navitje z najvišjo napetostjo za opremo med 3,6 kV in 36 kV; - sekundarno (nizkonapetostno) navitje z najvišjo napetostjo za opremo, ki ne presega 1,1 kV. Pri uporabi na prostem je treba zahtevati posebno obliko ali ohišje (ohišje s prilagojenimi stopnjami zaščite IP in IK).

General Information

Status
Withdrawn
Publication Date
28-Apr-2011
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
25-Jun-2018
Completion Date
17-May-2017

Relations

Buy Standard

Standard
EN 50541-1:2011
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Trifazni suhi distribucijski transformatorji, 50 Hz, od 100 do 3150 kVA, za napetosti, ki ne presegajo 36 kV - 1. del: Splošne zahteve in zahteve za suhi tip transformatorjev za napetosti, ki ne presegajo 36 kVDrehstrom-Trocken-Verteilungstransformatoren, 50 Hz, 100 kVA bis 3 150 kVA, mit einer höchsten Spannung für Betriebsmittel kleiner oder gleich 36 kV - Teil 1: Allgemeine AnforderungenTransformateurs triphasés de distribution de type sec, 50 Hz, de 100 kVA à 3 150 kVA, avec une tension la plus élevée pour le matériel ne dépassant pas 36 kV - Partie 1: Prescriptions généralesThree phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements29.180Transformatorji. DušilkeTransformers. ReactorsICS:Ta slovenski standard je istoveten z:EN 50541-1:2011SIST EN 50541-1:2011en01-julij-2011SIST EN 50541-1:2011SLOVENSKI
STANDARDSIST HD 538.2 S1:1997SIST HD 538.1 S1:1997/A1:1997SIST HD 538.1 S1:19971DGRPHãþD



SIST EN 50541-1:2011



EUROPEAN STANDARD EN 50541-1 NORME EUROPÉENNE
EUROPÄISCHE NORM April 2011
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50541-1:2011 E
ICS 29.180 Supersedes HD 538.1 S1:1992 + A1:1995, HD 538.2 S1:1995
English version
Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV -
Part 1: General requirements
Transformateurs triphasés de distribution de type sec, 50 Hz, de 100 kVA à 3 150 kVA, avec une tension la plus élevée pour le matériel ne dépassant pas 36 kV -
Partie 1: Prescriptions générales
Drehstrom-Trocken-Verteilungstransformatoren, 50 Hz, 100 kVA bis 3 150 kVA, mit einer höchsten Spannung für Betriebsmittel kleiner oder gleich 36 kV -
Teil 1: Allgemeine Anforderungen
This European Standard was approved by CENELEC on 2011-01-02. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
SIST EN 50541-1:2011



EN 50541-1:2011 – 2 – Foreword This European Standard was prepared by the Technical Committee CENELEC TC 14, Power transformers.
The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50541-1 on 2011-01-02. This document supersedes HD 538.1 S1:1992 + A1:1995 and HD 538.2 S1:1995. The following dates were fixed: – latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement
(dop)
2012-01-02 – latest date by which the national standards conflicting with the EN have to be withdrawn
(dow) 2014-01-02 __________ SIST EN 50541-1:2011



– 3 – EN 50541-1:2011 Contents 1Scope . 52Normative references . 53Electrical characteristics . 63.1Rated power . 63.2Highest voltages for equipment of windings . 63.3Rated voltages of windings . 63.3.1For the high-voltage winding . 63.3.2For the low voltage winding . 63.4Tapping .
...