HD 478.2.3 S1:1990
(Main)Classification of environmental conditions - Part 2: Environmental conditions appearing in nature - Air pressure
- BACK
- 04-Jan-1990
- 31-Aug-1990
- CLC/SR 104
Classification of environmental conditions - Part 2: Environmental conditions appearing in nature - Air pressure
Indicates values of air pressure to which products are liable to be exposed during storage, transportation and use.
Klassifizierung von Umweltbedingungen - Teil 2: Natürliche Einflüsse - Luftdruck
Classification des conditions d'environnement - Partie 2: Conditions d'environnement présentes dans la nature - Pression atmosphérique
Indique les valeurs de pression atmosphérique auxquel les des produits sont susceptibles d'être exposés pendant leur stockage, leur transport et leur utilisation.
Classification of environmental conditions - Part 2: Environmental conditions appearing in nature - Air pressure
General Information
Relations
Standards Content (Sample)
SLOVENSKI SIST HD 478.2.3 S1:2003
STANDARD
julij 2003
Classification of environmental conditions - Part 2: Environmental conditions
appearing in nature - Air pressure
ICS 19.040 Referenčna številka
SIST HD 478.2.
...
This May Also Interest You
IEC 60335-2-39:2012 deals with the safety of electrically operated commercial multi-purpose cooking pans not intended for household and similar use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances. This standard also deals with pressurized appliances and appliances with pressurized parts. These appliances are used for processing food for commercial consumption, for example in kitchens of restaurants, canteens, hospitals and in commercial enterprises such as bakeries, butcheries, etc. The electrical part of appliances making use of other forms of energy is also within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by these types of appliances. Attention is drawn to the fact that for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary. The principal changes in this edition as compared with the fifth edition of IEC 60335-2-39 are as follows (minor changes are not listed): - addition to definition of portable appliances, atmospheric multi-purpose cooking and rated pressure; - deletion of equipotential symbol 5021 of IEC 60417 covered by Part 1; - addition of instructions for multi-purpose cooking pans; - modification on leakage current permissible for portable class l appliances; - addition to abnormal test requirements; - addition to mechanical hazard test for multi-purpose cooking pans; - addition of construction test for multi-purpose cooking pans; - addition to construction requirements for lids and theirs grips; - addition to construction requirements for positioning of pressure reliefs; - addition to construction's fixed appliances which are moved forward and backward for cleaning purposes.
The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of publication. Keywords: Multi-purpose cooking pans.
- Draft21 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60034-9:2021 specifies test methods for the determination of sound power level of rotating electrical machines and specifies maximum A-weighted sound power levels for factory acceptance testing of network-supplied, rotating electrical machines in accordance with lEC 60034-1, having methods of cooling according to lEC 60034-6 and degrees of protection according to lEC 60034-5, and having the following characteristics: - standard design, either AC or DC, without additional special electrical, mechanical, or acoustical modifications intended to reduce the sound power level - rated output from 1 kW (or kVA) up to and including 5 500 kW (or kVA) - rated speed not greater than 3 750 min–1 This fifth edition cancels and replaces the fourth edition, published in 2003 and its amendment 1, published in 2007. This edition includes the following significant technical changes with respect to the previous edition: a) In Table 2 and Table 3 cooling methods IC01, IC11, IC21 and IC31, IC71, IC81 are now covered. b) This edition adds Table 3 for 60 Hz machines, whereas Table 2, which covers only 50 Hz machines, has no change in levels. c) In Table 3, grade A is added to harmonize the highest levels seen in IEC and NEMA, whereas grade B was added to harmonize the lowest, more restrictive levels seen in IEC and NEMA. d) The clause “Determination of noise increments caused by converter supply” has been shifted to Annex B and renamed “Information on typical noise increments caused by converter supply”.
- Draft20 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Nov-2024
- 12-Jun-2022
- 29.160
- 29.160.01
- 2014/35/EU
- M/511
- CLC/TC 2
IEC 60034-12:2024 is available as IEC 60034-12:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60034-12:2024 specifies the parameters for eight designs of starting performance of single-speed three-phase 50 Hz or 60 Hz cage induction motors in accordance with IEC 60034‑1 that: - have a rated voltage up to 1 000 V; - are intended for direct-on-line or star-delta starting; - are rated on the basis of duty type S1; - are constructed to any degree of protection as defined in IEC 60034-5 and explosion protection. This document also applies to dual voltage motors provided that the flux saturation level is the same for both voltages. This fourth edition cancels and replaces the third edition published in 2016. Aligned with the requirements for explosion protected motors from TC31 WG27 - new clause on methods for measuring locked-rotor current and torque; - new informative annex on the general current and torque characteristics with locked rotor; - new informative annex on correction of voltage and frequency; - aligned with the requirements for explosion protected motors from TC31 WG27.
- Draft20 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Nov-2024
- 29.160.01
- 2014/35/EU
- M/511
- CLC/TC 2
This European Standard deals with the safety of electric heat pumps, sanitary hot water heat pumps and air conditioners, incorporating motor-compressors as well as hydronic fan coils units, dehumidifiers (with or without motor-compressors), thermoelectric heat pumps and partial units. Their maximum rated voltage being not more than 300 V for single phase appliances and 600 V for multi-phase appliances. Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.
- Draft22 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60034-11:2020 is available as IEC 60034-11:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60034-11:2020 specifies requirements relating to the use of thermal protectors and thermal detectors incorporated into the stator windings or placed in other suitable positions in induction machines in order to protect them against serious damage due to thermal overloads. It applies to single-speed three-phase 50 Hz or 60 Hz cage induction motors in accordance with IEC 60034-1 and IEC 60034-12 that: - have a rated voltage up to 1 000 V; - are intended for direct-on-line or star-delta starting. The main changes with respect to the previous edition are: - the additional specification of winding temperature limits for temperature class 200 (N), - the increased limits of maximum winding temperatures for overloads with rapid variation, - the clarification that the motor winding may be permanently damaged after it has been exposed to temperatures - a clarification of the definition of indirect thermal protection, - a clarification on the test methods for larger motors.
- Draft13 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Nov-2024
- 23-May-2021
- 29.160
- 29.160.01
- 2014/35/EU
- M/511
- CLC/TC 2
This European Standard deals with the safety of electric heat pumps, sanitary hot water heat pumps and air conditioners, incorporating motor-compressors as well as hydronic fan coils units, dehumidifiers (with or without motor-compressors), thermoelectric heat pumps and partial units. Their maximum rated voltage being not more than 300 V for single phase appliances and 600 V for multi-phase appliances. Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.
- Draft158 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60704-2-10:2024 applies to ranges, ovens, steam ovens, grills and microwave ovens for household and similar use. This document does not apply to hobs. This document does not apply to appliances or parts of appliances that use gas energy. Requirements for the declaration of noise emission values are not within the scope of this document. This third edition cancels and replaces the second edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) alignment with the fourth edition of IEC 60704-1:2021; b) alignment with IEC 60350-1:2023 regarding the definitions and settings; c) introduction of the measurement of the steam function; d) revision of settings and test parameters. This document is intended to be used in conjunction with IEC 60704-1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.
- Standard16 pagesEnglish languagesale 10% offe-Library read for×1 day
- 31-Oct-2024
- 17.140.20
- 97.040.20
- CLC/TC 59X
IEC 62271-211:2024 is applicable to single- and three-phase direct connections between gas-insulated metal-enclosed switchgear (GIS) for rated voltages above 52 kV and transformer arrangements to establish electrical and mechanical interchange ability and to determine the limits of supply for the transformer connection. This second edition cancels and replaces the first edition of IEC 62271-211:2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) re-numbering of clauses according to IEC 62271-1:2017, b) Clause 3: updating definition about bushing (3.1), updating some pressure definitions (3.6, 3.7, 3.8, 3.9), rewording definition about proctor density (3.11), new term very-fast-front overvoltage (3.12), c) Clause 5 (former clause 4): add a subclause 5.1 General, according to IEC 62271-1:2017 and IEC 62271-203:2022, 1) subclause 5.5: new first paragraph, rewording second paragraph, 2) subclause 5.8: modify the term "Rated duration of thermal short-time current" of the bushing, d) Clause 6 (former Clause 5): restructure and rewording of subclauses: 1) 6.1 (former 5.3): requirements about gas and vacuum tightness of the transformer bushing 2) 6.3 (former 5.2): harmonization with IEC 62271-203:2022 about typical maximum pressure in service for SF6, other gases and gas mixtures, 3) 6.4 (former 5.8), rewording 4) 6.5 (former 5.1), some rewording and modification 5) 6.6 (former 5.4), some rewording, updated references 6) 6.7 (former 5.5), some rewording 7) 6.8 (former 5.6), some rewording 8) 6.9 (former 5.7), slight rewording, e) Clause 7 (former clause 6) type tests: some rewording and clarifications about references, f) Clause 8 (former clause 7) routine tests: 1) 8.2 (former 7.2): add a paragraph about SF6-mixtures and other gases than SF6, 2) 8.3 (former 7.3): update reference to relevant on-site test according to IEC 62271‑203:2022, g) Clause 9 Guide to the selection of switchgear and controlgear (new): informative, to have a reference to IEC 62271-203:2022, h) Clause 11 (former 10): updated headline and updated reference according to IEC 62271‑1:2017, i) new Clauses 12 Safety and 13 Environmental aspects: Adding of references to safety and environmental aspects, j) correction of errors in Corrigendum 2 of IEC 62271-211:2017, k) modified orientation of Figure 1 to Figure 4 for easier reading of the tables.
- Standard28 pagesEnglish languagesale 10% offe-Library read for×1 day
- 31-Oct-2024
- 29.130.10
- CLC/TC 17AC
This document applies to the application design and installation of electrical equipment, control circuits and safety-related systems for furnaces which are operated with solid, liquid or gaseous fuels and their ancillary equipment. It specifies requirements to meet the operating conditions of furnaces, to reduce the hazards of combustion and to protect the heated systems from damage e.g. by overheating. Such furnaces and the electrical equipment can be part by way of example of the following plant: a) water heating systems; b) steam boiler installations (steam and hot-water boilers) and heat recovery steam boilers; NOTE 1 The requirements of this document apply according to the electrical equipment of electrically heated steam boilers. NOTE 2 Seagoing vessels and offshore facilities are governed by International Maritime Law and as such are not within the scope of this document. These requirements can be used for such facilities. c) warm air heaters; d) hot-gas heaters; e) heat exchanger systems; f) combustion chambers of stationary turbines; g) as long as no other standard is applicable for combined heat and power stations, we recommend the use of the requirements of this document; This document can also be used as reference for electrical equipment requirements for thermo-processing equipment. The requirements in this document are not applicable to electrical equipment for: 1) non-electrically heated appliances and burner control systems for household and similar purposes; 2) furnaces using technologies for the direct conversion of heat into electrical energy; 3) combustion chambers of non-stationary prime movers and turbines; 4) central oil supply systems for individual heating appliances; 5) furnaces using solid fuels for heating purposes for household use with a nominal thermal output up to 1 MW; 6) furnaces which are used to heat process fluids and gasses in chemical plant. This document can be used as a basis for the requirements placed on electrical equipment for furnaces, which are excluded from its field of application. This document specifies special requirements for the management of functional safety.
- Draft101 pagesEnglish languagesale 10% offe-Library read for×1 day
- 31-Oct-2024
- 27.060.01
- 2014/35/EU
- M/511
- CLC/BTTF 132-2
IEC 60308:2024 deals with the definition and the characteristics of control systems. It is not limited to the actual controller tasks but also includes other tasks which may be assigned to a control system, such as sequence control tasks, safety and provision for the actuating energy. The following systems are included, speed, power, opening, water level and flow control for all turbine types; electronic, electrical and fluid power devices; safety devices as well as start-up and shutdown devices. The significant technical changes introduced by the third edition are the adoption of parts of IEC 61362:2024 which deal with test matters and the introduction of new technical aspects.
- Draft89 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.