SLOVENSKI STANDARD
01-maj-2019
Konektorji za elektronsko opremo - 7. del: Podrobna specifikacija za 8-redne,
nezaslonjene, proste in fiksne konektorje - Dopolnilo A2 (IEC 60603-
7:2008/A2:2019)
Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded,
free and fixed connectors (IEC 60603-7:2008/A2:2019)
Steckverbinder für elektronische Einrichtungen - Teil 7: Bauartspezifikation für
ungeschirmte freie und feste Steckverbinder, 8polig (IEC 60603-7:2008/A2:2019)
Connecteurs pour équipements électroniques - Partie 7: Spécification particulière pour
les fiches et les embases non écrantées à 8 voies (IEC 60603-7:2008/A2:2019)
Ta slovenski standard je istoveten z: EN 60603-7:2009/A2:2019
ICS:
31.220.10 9WLþLLQYWLþQLFHNRQHNWRUML Plug-and-socket devices.
Connectors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 60603-7:2009/A2
NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2019
ICS 31.220.10
English Version
Connectors for electronic equipment - Part 7: Detail specification
for 8-way, unshielded, free and fixed connectors
(IEC 60603-7:2008/A2:2019)
Connecteurs pour équipements électroniques - Partie 7: Steckverbinder für elektronische Einrichtungen - Teil 7:
Spécification particulière pour les fiches et les embases non Bauartspezifikation für ungeschirmte freie und feste
écrantées à 8 voies Steckverbinder, 8polig
(IEC 60603-7:2008/A2:2019) (IEC 60603-7:2008/A2:2019)
This amendment A2 modifies the European Standard EN 60603-7:2009; it was approved by CENELEC on 2019-02-15. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60603-7:2009/A2:2019 E
European foreword
The text of document 48B/2679/FDIS, future IEC 60603-7:2008/A2, prepared by SC 48B "Electrical
connectors" of IEC/TC 48 "Electrical connectors and mechanical structures for electrical and electronic
equipment" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2019-11-15
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2022-02-15
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Endorsement notice
The text of the International Standard IEC 60603-7:2008/A2:2019 was approved by CENELEC as a
European Standard without any modification.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Add the following reference :
Publication Year Title EN/HD Year
IEC 61076-3 2008 Connectors for electronic equipment - EN 61076-3 2008
Product requirements - Part 3: Rectangular
connectors - Sectional specification
IEC 60603-7 ®
Edition 3.0 2019-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
A MENDMENT 2
AM ENDEMENT 2
Connectors for electronic equipment –
Part 7: Detail specification for 8-way, unshielded, free and fixed connectors
Connecteurs pour équipements électroniques –
Partie 7: Spécification particulière pour les fiches et les embases non écrantées
à 8 voies
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 31.220.01 ISBN 978-2-8322-6251-1
– 2 – IEC 60603-7:2008/AMD2:2019
© IEC 2019
FOREWORD
This amendment has been prepared by subcommittee 48B: Electrical connectors, of IEC
technical committee 48: Electrical connectors and mechanical structures for electrical and
electronic equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
48B/2679/FDIS 48B/2689/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the stability date indicated on the IEC website under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________
1.1 Scope
Add the following new paragraph at the end of the subclause:
Annex E (normative) is added to provide details regarding the levels of compatibility to be
declared by the manufacturer as appropriate.
1.2 Normative references
Add the following new reference:
IEC 61076-3:2008, Connectors for electrical and electronic equipment – Product requirements
– Part 3: Rectangular connectors – Sectional specification
2 Terms and definitions
Replace definitions 2.1 and 2.2 with the following:
2.1
intermateability
intermateability (level 2 of IEC 61076-1:2006) is ensured by application of the “Go” and “No-
Go” gauge requirements in the standards that may be referenced, and by adherence to the
dimensional requirements within
SEE: Clause E.3.
IEC 60603-7:2008/AMD2:2019 – 3 –
© IEC 2019
2.2
interoperability
interoperability of different IEC 60603-7 connectors and of IEC 60603-7 connectors with
connectors of other families (e.g. IEC 61076-3 series) is ensured by compliance with the
specified interface dimensions, when they have the same number of contacts, the same
electrical wiring-related dimensions and when the lowest electrical, mechanical and climatic
performance (performance level) among the two connectors is suitable for the intended
application
SEE: Clause E.5.
Add, after Subclause 2.4, the following new terms and definitions:
2.5
number of contacts
number of contacts (or ways) that a connector owns, including the protective and/or functional
earth contact(s), if any
Note 1 to entry: A connector for removable contacts is characterized by its number of contact positions (seats): its
number of contacts (ways) may be lower than the number of contact positions (seats).
Note 2 to entry: The same number of contacts does not grant the same electrical interface: the geometry of said
contacts may be different while their number is the same.
2.6
overall dimensions
dimensions providing the overall space occupied by a connector
Note 1 to entry: Two connectors of the same gender may have the same overall dimensions but different
mounting dimensions and/or different interface dimensions.
2.7
interface dimensions
set of dimensions required to fully describe the connector’s mating interface, belonging to
both the connector insert and to the relevant electric contacts
Note 1 to entry: Interface dimensions enable the proper functioning of a mated set of connectors according to the
relevant product detail specification or manufacturer’s detail specification.
Note 2 to entry: Two connectors with same interface dimensions have the same number of contact seats (or
positions), whereas they may not show the same number of contacts (ways).
2.8
mounting dimensions
dimensions enabling the mounting of a connector
Note 1 to entry: Examples of mounting dimensions are panel cutout size, size and interaxes of fixing holes or
threads.
Note 2 to entry: The geometry of the mounting interface of Printed Circuit Board connectors to the PCB belongs
to the mounting dimensions: two Printed Circuit Board connectors of the same gender with the same mounting
dimensions share the same pattern and pitch of their contacts.
Note 3 to entry: Two connectors not of the Printed Circuit Board type of the same gender with the same mounting
dimensions may have different interface dimensions.
Note 4 to entry: Two connectors of the same gender with the same mounting dimensions may have different
overall dimensions.
2.9
electrical wiring-related dimensions
dimensions related to the wiring of the connector, i.e. to its number and type of contacts
(ways)
– 4 – IEC 60603-7:2008/AMD2:2019
© IEC 2019
Note 1 to entry: Two connectors of the same gender with the same electrical wiring-related dimensions have the
same number of contacts (ways) or contact positions (seats), the same dimensions of these contacts or contact
positions, the same overall dimensions, the same interface dimensions, and if they are Printed Circuit Board
connectors, the same mounting dimensions
2.10
electrical, mechanical and climatic performances
levels of electrical, mechanical and climatic performance assigned to a connector in the
relevant product detail specification or manufacturer’s detail specification, therein verified
through dedicated groups of tests
Note 1 to entry: The electrical performance includes signal integrity.
________________________________________________________________
This space intentionally left blank
IEC 60603-7:2008/AMD2:2019 – 5 –
© IEC 2019
Add the following new Annex E (normative):
Annex E
(normative)
Levels of compatibility
E.1 General
In applications where connectors according to IEC 60603-7 are used, a mixture of connectors
from different sources may be available. In cases where these products were given a different
rating by the manufacturer, and also when dimensional details are deviating, it is important to
know and consider the right level of compatibility.
The levels of compatibility are intended to compare connectors of the same gender on their
capability to be mated with a complementary connector of the different gender. The levels
indicate the functional differences (if any) between connector products of the same gender but
from different sources.
A product detail specification under this standard may declare a certain level of compatibility –
e.g. in terms of backward compatibility or of interoperability – with other product detail
specification(s) within the same family of standards (e.g. this IEC 60603-7 family or
IEC 61076-3 family) or with a cross reference to a connector covered by a product detail
specification belonging to a different IEC family.
In fact, for historical reasons some recent additions have been assigned to this IEC 60603-7
family of standards, while other new connectors have been assigned to the IEC 61076-3
family of rectangular connectors. For this reason a similar Annex has been included in the
generic specification IEC 61076-1 in order to align the terminology used in both families in
regard to levels of compatibility.
The levels of compatibility between connectors from different sources are characterized – as
a function of the standardization degree – by 4 levels. These levels are already defined in
2.2.3.2 to 2.2.3.5 of IEC 61076-1:2006 and shall, when appropriate, be indicated in the
relevant detail product specification of connectors.
_________________________________________________________________________
This space intentionally left blank
– 6 – IEC 60603-7:2008/AMD2:2019
© IEC 2019
In Table E.1, for each level of compatibility the required parameters are indicated by “x” in a
graphical way.
b) c) b)
Table E.1 – Levels of compatibility and required parameters
Level of Number of Overall Interface Mounting Electrical Electrical,
compatibility contacts dimensions dimensions dimensions wiring-related mechanical
of IEC 61076-1 dimensions and climatic
performance
a)
Intermountable Level 1 x x
a)
Intermateable Level 2 x x
a)
Intermountable and
Lev
...
Questions, Comments and Discussion